Loading...
HomeMy WebLinkAbout1618 East Wayne Street_AA 2020-0603Michele Gelfman, President HISTORIC PRESERVATION COMMISSION OF SOUTH BEND AND ST. JOSEPH COUNTY CERTIFICATE OF APPROPRIATENESS The Historic Preservation Commission of South Bend and St. Joseph County has approved the following work: Complete tear off of asphalt shingles on house and garage. New CertainTeed Architectural shingles and complete roof system. Exterior paint maintenance on trim, soffits, gutters, and shutters. New in-kind wood soffit. New in-kind wood crown molding at top of house. RELIABLE ROOFING, Contractor for the following location: 1618 WAYNE ST South Bend, IN, 46615 East Wayne Street Application No. 2020-0603 in the County of St. Joseph; State of Indiana; which is: Located in a Local Historic District A Local Historic Landmark and found this application to be appropriate according to the Standards pertaining to Local Historic Landmarks and/or Local Historic Districts. Regulations pertaining to the Historic Preservation Commission are found in Chapter 21 (Zoning), South Bend Municipal Code and Chapter 26 of the St. Joseph County Code. The issuance of this certificate does NOT in any manner, release the recipient from the responsibility of complying with the requirements of the zoning ordinances, building codes, safety codes, ADA or other requirements of the City of South Bend, the County of St. Joseph, the State of Indiana, or the United States Federal Government. This certificate is good for one year from the date of issuance and is effective from the date entered herein. Plans are on file and open for public inspection at the office of the Historic Preservation Commission of South Bend and St. Joseph County, 227 West Jefferson Blvd., Suite 1400 S, South Bend, Indiana, during normal business hours. THIS CERTIFICATE IS NOT TRANSFERABLE NAME OF APPLICANT:Catherine and Eugene McSweeney CERTIFICATE ISSUED BY: Elicia Feasel Historic Preservation Administrator POST IN A CONSPICUOUS PLACE ON THE STREET SIDE OF THE PROJECT UNTIL COMPLETION OF ALL WORK. Phone: (574) 235-9371 E-mail: SBSJCHPC@southbendin.gov ELICIA FEASEL Historic Preservation Administrator 6/3/2020DATE CERTIFICATE TAKES FORCE:6/3/2021DATE CERTIFICATE EXPIRES: Ord No. 7796-87 East Wayne Street ADMINISTRATIVE APPROVAL HISTORIC PRESERVATION COMMISSION OF SOUTH BEND AND ST. JOSEPH COUNTY County—City Building, South Bend, IN 46601 http://www.southbendin.gov/government/department/community-investment Phone: 574/235.9371 Fax: 574/235.9021 Email: hpcsbsjc@southbendin.gov Michele Gelfman, President A Certified Local Government of the National Park Service Elicia Feasel, Historic Preservation Administrator OFFICE USE ONLY>>>>>>DO NOT COMPLETE ANY ENTRIES CONTAINED IN THIS BOX<<<<<<OFFICE USE ONLY Date Received: ____________________ Application Number: ____________—___________________________________ Past Reviews: YES (Date of Last Review) _____________________________ NO Staff Approval authorized by: _________________________________________________________ Title: __________________________ Historic Preservation Commission Review Date: __________________________________________________________________________ Local Landmark Local Historic District (Name) ________________________________________ National Landmark National Register District (Name) _____________________________________ Certificate Of Appropriateness: Denied Tabled Sent To Committee Approved and issued: _____________________ Address of Property for proposed work: ________________________________________________________________________ (Street Number—Street Name—City—Zip) Name of Property Owner(s): __________________________________________________ Phone #: ______________________ Address of Property Owner(s): _______________________________________________________________________________ (Street Number—Street Name—City—Zip) Name of Contractor(s): _______________________________________________________ Phone #: ______________________ Contractor Company Name: __________________________________________________________________________________ Address of Contractor Company: ______________________________________________________________________________ (Street Number—Street Name—City—Zip) Current Use of Building: _____________________________________________________________________________________ (Single Family—Multi-Family—Commercial—Government—Industrial—Vacant—etc.) Type of Building Construction: ________________________________________________________________________________ (Wood Frame—Brick—Stone—Steel—Concrete—Other) Landscape New Replacement (not in-kind) Demolition Proposed Work: (more than one box may be checked) Description of Proposed Work: _______________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ ___________________________________________________________________________________________________________ Owner e-mail: __________________________________ and/or Contractor e-mail: ___________________________________ X _______________________________________________ and/or X _______________________________________________ Signature of Owner Signature of Contractor By signing this application I agree to abide by all local regulations related to project and to obtain a Building Department Permit, if applicable. —APPLICATION REQUIREMENTS ARE LISTED ON REVERSE SIDE— APPLICATION FOR A — CERTIFICATE OF APPROPRIATENESS 1 Elicia Feasel From:Elicia Feasel Sent:Tuesday, June 2, 2020 2:54 PM To:Jonathan Gonzalez Subject:Re: 1618 E Wayne St. Your typical Eagleview is a good resource. I will issue it as an administrative approval.    From: Jonathan Gonzalez <joogonza@gmail.com>  Sent: Tuesday, June 2, 2020 1:31:19 PM  To: Elicia Feasel <efeasel@southbendin.gov>  Subject: 1618 E Wayne St.          Elicia,    It seems that the customer has changed their minds and wants their house fixed. They are willing to just replace the  wood panels and install like material wood panels under the soffit.    Does this still require a site plan, would a satellite image of the property suffice?    Thank you    Best Regards,   ‐‐   Jonathan Gonzalez  CFO  Reliable Roofing & Construction   www.reliableroofingonline.com  Office: 574.302.7977         1618 Wayne St, South Bend, IN 46615-1334 Prepared for you by Reliable Roofing & Construciton Reliable Roofing and Construction 423 S Michigan St South Bend, IN 46601 Trevor Long tel.(574) 302-7977 email:esaugordillo@gmail.com http://reliableroofingonline.com Precise Aerial Roof Measurement Report Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. Measurements provided by www.eagleview.com www.eagleview.com/Guarantee.aspx In this 3D model, facets appear as semi-transparent to reveal overhangs. PREPARED FOR Contact:Abraham Gordillo Company:Reliable Roofing & Construction Address:423 S Michigan St South Bend, IN 46601 Phone:574-302-7977 TABLE OF CONTENTS Images .....................................................................1 Length Diagram .........................................................4 Pitch Diagram ............................................................5 Area Diagram ............................................................6 Notes Diagram ...........................................................7 Report Summary ......................................................10 Total Roof Area =3,863 sq ft Total Roof Facets =15 Predominant Pitch =8/12 Number of Stories >1 Total Ridges/Hips =123 ft Total Valleys =66 ft Total Rakes =270 ft Total Eaves =245 ft MEASUREMENTS Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 IMAGES © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 1 The following aerial images show different angles of this structure for your reference. Top View Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 IMAGES © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 2 North Side South Side Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 IMAGES © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 3 East Side West Side Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 LENGTH DIAGRAM © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 4 Note: This diagram contains segment lengths (rounded to the nearest whole number) over 5.0 Feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9). Total Line Lengths: Ridges = 118 ft Hips = 5 ft Valleys = 66 ft Rakes = 270 ft Eaves = 245 ft Flashing = 84 ft Step flashing = 40 ft Parapets = 0 ft 34 171734 17162322 17311920 772312 +6 1020 222217 1722 29 1325 131911 111 1 1916823168 S N W E 2020 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 PITCH DIAGRAM © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 5 Note: This diagram contains labeled pitches for facet areas larger than 20.0 square feet. In some cases, pitch labels have been removed for readability. Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this roof is 8/12 8  +6   +6 8 4 8 +6  7  8  8  7 2 2 2 2 S N W E 2020 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 AREA DIAGRAM © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 6 Note: This diagram shows the square feet of each roof facet (rounded to the nearest Foot). The total area in square feet, at the top of this page, is based on the non-rounded values of each roof facet (rounded to the nearest square foot after being totaled). Total Area = 3,863 sq ft, with 15 facets. 42 153 153 366 420 30 320 452 42 576 454 366 451 28 +9 S N W E 2020 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 NOTES DIAGRAM © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 7 Roof facets are labeled from smallest to largest (A to Z) for easy reference. D G F I K C H L E O M J N B A S N W E 2020 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 REPORT SUMMARY © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 8 Structure #1 Areas per Pitch Roof Pitches Area (sq ft) % of Roof 8/12 7/12 4/12 2/12 895.3 905.9 29.5 855 33.3%33.7%1.1%31.8% The table above lists each pitch on this roof and the total area and percent (both rounded) of the roof with that pitch. Structure Complexity Simple Normal Complex Waste Calculation NOTE: This waste calculation table is for asphalt shingle roofing applications. All values in table below only include roof areas of 3/12 pitch or greater. For total measurements of all pitches, please refer to the Lengths, Areas, and Pitches section below. Waste %0%5%8%10%12%15%20%25%30% Area (Sq ft)1831 1923 1978 2015 2051 2106 2198 2289 2381 Squares *18.33 19.33 20.00 20.33 20.66 21.33 22.00 23.00 24.00 Measured Suggested * Squares are rounded up to the 1/3 of a square. Additional materials needed for ridge, hip, and starter lengths are not included in the above table. The provided suggested waste factor is intended to serve as a guide—actual waste percentages may differ based upon several variables that EagleView does not control. These waste factor variables include, but are not limited to, individual installation techniques, crew experiences, asphalt shingle material subtleties, and potential salvage from the site. Individual results may vary from the suggested waste factor that EagleView has provided. The suggested waste is not to replace or substitute for experience or judgment as to any given replacement or repair work. Total Roof Facets = 9 Lengths, Areas and Pitches Ridges = 66 ft (2 Ridges) Hips = 5 ft (2 Hips). Valleys = 45 ft (2 Valleys) Rakes† = 166 ft (13 Rakes) Eaves/Starter‡ = 166 ft (10 Eaves) Drip Edge (Eaves + Rakes) = 332 ft (23 Lengths) Parapet Walls = 0 (0 Lengths). Flashing = 84 ft (7 Lengths) Step flashing = 14 ft (6 Lengths) Predominant Pitch = 7/12 Total Area (All Pitches) = 2686 sq ft Property Location Longitude = -86.2234315 Latitude = 41.6728328 Notes This was ordered as a residential property. There were no changes to the structure in the past four years. 1 2 S N W E 2020 Eagle View Technologies, Inc., All Rights Reserved.† Rakes are defined as roof edges that are sloped (not level). ‡ Eaves are defined as roof edges that are not sloped and level. Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 REPORT SUMMARY © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 9 Structure #2 Areas per Pitch Roof Pitches Area (sq ft) % of Roof 8/12 6/12 450.7 725.6 38.3%61.7% The table above lists each pitch on this roof and the total area and percent (both rounded) of the roof with that pitch. Structure Complexity Simple Normal Complex Waste Calculation NOTE: This waste calculation table is for asphalt shingle roofing applications. All values in table below only include roof areas of 3/12 pitch or greater. For total measurements of all pitches, please refer to the Lengths, Areas, and Pitches section below. Waste %0%4%9%12%14%16%19%24%29% Area (Sq ft)1177 1225 1283 1319 1342 1366 1401 1460 1519 Squares *12.00 12.33 13.00 13.33 13.66 13.66 14.33 14.66 15.33 Measured Suggested * Squares are rounded up to the 1/3 of a square. Additional materials needed for ridge, hip, and starter lengths are not included in the above table. The provided suggested waste factor is intended to serve as a guide—actual waste percentages may differ based upon several variables that EagleView does not control. These waste factor variables include, but are not limited to, individual installation techniques, crew experiences, asphalt shingle material subtleties, and potential salvage from the site. Individual results may vary from the suggested waste factor that EagleView has provided. The suggested waste is not to replace or substitute for experience or judgment as to any given replacement or repair work. Total Roof Facets = 6 Lengths, Areas and Pitches Ridges = 53 ft (4 Ridges) Hips = 0 ft (0 Hips). Valleys = 22 ft (2 Valleys) Rakes† = 105 ft (8 Rakes) Eaves/Starter‡ = 80 ft (6 Eaves) Drip Edge (Eaves + Rakes) = 185 ft (14 Lengths) Parapet Walls = 0 (0 Lengths). Flashing = 0 ft (0 Lengths) Step flashing = 27 ft (4 Lengths) Predominant Pitch = 6/12 Total Area (All Pitches) = 1177 sq ft Property Location Longitude = -86.2234315 Latitude = 41.6728328 Notes This was ordered as a residential property. There were no changes to the structure in the past four years. 1 2 S N W E 2020 Eagle View Technologies, Inc., All Rights Reserved.† Rakes are defined as roof edges that are sloped (not level). ‡ Eaves are defined as roof edges that are not sloped and level. Premium Report 5/30/2020 1618 Wayne St, South Bend, IN 46615-1334 Report: 34233253 REPORT SUMMARY © 2008-2020 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 10 All Structures Areas per Pitch Roof Pitches Area (sq ft) % of Roof 2/12 4/12 6/12 7/12 8/12 855.1 29.5 725.6 905.9 1346.1 22.1%0.8%18.8%23.5%34.8% The table above lists each pitch on this roof and the total area and percent (both rounded) of the roof with that pitch. All Structures Totals Total Roof Facets = 15 Lengths, Areas and Pitches Ridges = 118 ft (6 Ridges) Hips = 5 ft (2 Hips). Valleys = 66 ft (4 Valleys) Rakes† = 270 ft (21 Rakes) Eaves/Starter‡ = 245 ft (16 Eaves) Drip Edge (Eaves + Rakes) = 515 ft (37 Lengths) Parapet Walls = 0 (0 Lengths). Flashing = 84 ft (7 Lengths) Step flashing = 40 ft (10 Lengths) Predominant Pitch = 8/12 Total Area (All Pitches) = 3,863 sq ft Property Location Longitude = -86.2234315 Latitude = 41.6728328 Notes This was ordered as a residential property. There were no changes to the structure in the past four years. Measurements by Structure Structure Area (sq ft) Ridges (ft) Hips (ft)Valleys (ft) Rakes (ft) Eaves (ft) Flashing (ft) Step Flashing (ft) Parapet s (ft) 1 2686 66 5 45 166 166 84 14 0 2 1176 53 0 22 105 80 0 27 0 All values in this table are rounded up to the nearest Foot for each separate structure. Measurement totals displayed elsewhere in this report are added together before rounding which may cause totals to differ. The table above lists each pitch on this roof and the total area and percent (both rounded) of the roof with that pitch. Online Maps Online map of property http://maps.google.com/maps?f=g&source=s_q&hl=en&geocode=&q=1618+Wayne+St,South+Bend,IN,46615-1334 Directions from Reliable Roofing & Construction to this property http://maps.google.com/maps?f=d&source=s_d&saddr=423+S+Michigan+St,South+Bend,IN,46601&daddr=1618+Wayne+St,South+ Bend,IN,46615-1334 1 2 S N W E 2020 Eagle View Technologies, Inc., All Rights Reserved.† Rakes are defined as roof edges that are sloped (not level). ‡ Eaves are defined as roof edges that are not sloped and level.