HomeMy WebLinkAbout6A(2)SOUT$ A,t,.
Community & Economic Development
1200 County -City Building, 227 West Jefferson, South Bend, Indiana 46601 -1830 Phone 574/235 -9371 Fax 574/235 -9021
To: Redevelopment Commission
From: Bill Schalliol, Economic Development Planner
Subject: Professional Service Proposal - Wightman Petrie, Inc.
Michiana Lock & Key Demolition & Site Reconstruction Project
Date: May 3, 2011
Attached to this memorandum is a multi -step professional service proposal from Wightman Petrie to
provide services to the City for the demolition of the former Michiana Lock & Key property and the
associated site redevelopment.
The proposal covers the general tasks related to demolition planning including the following:
1. Phase 1 Environmental Site Assessment
2. Ground Penetrating Radar Survey
3. Survey for Asbestos - Containing Materials
4. Demolition Specification Preparation
Task 2, the Ground Penetrating Radar Survey, which has become a new demolition planning item,
has become important to this specific demolition planning as local lore suggests that a railroad box
car might be buried in the parking area of the site. If that is the case, we need to understand where
additional site work might be needed during the demolition phase of this project.
This proposal also covers a fifth task which is Site Layout and Construction Design Services. As
part of the reuse of the site in conjunction with the Coveleski Park plan, a site plan and construction
drawings need to be prepared to develop a connector driveway between Monroe Street and the
adjacent parking area to the south as well as walk and driveway replacement plans and a code
compliant landscape plan need to be prepared for the property. The reuse of the site will be for
parking and transportation connectivity.
The total proposal amount is $13,500.00 and staff requests a not to exceed approval of $15,000.00
to cover unforeseen expenses related to site investigation and testing.
Staff request approval of this proposal.
What We Do Today Makes A Difference!
April 21, 2011
City of South Bend
Community and Economic Development
227 W. Jefferson Blvd., Suite 1200S
South Bend, Indiana 46601
Attention: Mr. Bill Schalliol
RE: PROPOSAL FOR PROFESSIONAL CONSULTING SERVICES, MICHAINA LOCK &
KEY FACILITY, 306 W. MONROE ST., SOUTH BEND, INDIANA,
PROPOSAL # WP11 -015
Dear Mr. Schalliol:
Wightman Petrie (WP) is pleased to submit this proposal for performing Professional Consulting Services
in support of the City of South Bend's recent acquisition of the former Michiana Lock & Key facility,
located at 306 W. Monroe Street, in South Bend.
It is our understanding that the City of South Bend is seeking to have the existing building demolished as
part of the overall redevelopment plan for the Coveleski Stadium Project. As such, the City of South
Bend is requesting the completion of a Phase I Environmental Site Assessment as documentation of the
presence or absence of any specific Recognized Environmental Conditions being associated with the
subject site. We also understand that the City of South Bend is concerned with the potential presence of
rubble and /or other debris that may be buried at the subject site and is therefore requesting that Ground
Penetrating Radar be used as a means for determining the presence or absence of any such subsurface
anomalies.
In addition, knowing that the existing facility (former residential dwelling and location for locksmith activity)
is to be demolished, the State of Indiana requires that a Survey for the presence of asbestos - containing
materials be undertaken, with actual abatement completed, prior to the initiation of any such demolition
activity. With respect to such demolition activity, the City of South Bend requires that a series of
"Demolition Specifications" be prepared for review by all potential bidders in the demolition process.
Such specifications make all bidders aware of the terms and conditions for the demolition, as well as any
specific environmental conditions for which special circumstances may exist (i.e., the presence of
asbestos containing materials for which abatement is necessary as part of the demolition project,
presence of underground storage tanks, etc.).
t Tt _'t� ,.FT tE
- SURVEYING ENGINEERING ENVIRONMENTAL, LANDSCAPE ARCHITECTURE
City of South Bend- Schalliol
April 21, 2011
Page 2
Finally, the City of South Bend is seeking to have the subject site completed as a paved parking lot for the
adjacent Zion Hill Missionary Baptist Church, as well as additional game day parking for patrons of
Coveleski Stadium. The parking lot shall provide vehicular access to both Monroe Street and the existing
parking lot to the south. A pedestrian walkway providing access towards the church shall also be
included in the proposed design. The City of South Bend is therefore requesting Engineering Services
(Site Design) to sufficiently provide details for future construction cost estimation, bid letting, and eventual
construction.
PROPOSED SCOPE OF SERVICES
The following subsections provide additional detail as to the Proposed Scope of Services, Estimated
Costs and Schedule for completion for the project:
Task 1— Phase I Environmental Site Assessment
It is the intent of Wightman Petrie to perform the Phase I in general accordance with the American Society
for Testing and Materials (ASTM) document ASTM E 1527 -05, which is considered consistent with the
provisions of the EPA's All Appropriate Inquiry.
The proposed Phase I Environmental Site Assessment will consist of the following components:
• Records Review
• Site Reconnaissance
• Interviews
• Reporting
RECORDS REVIEW
The purpose of the records review is to obtain and review records that will help identify environmental
concerns in connection with the subject site. As part of this phase of the project, we will attempt to obtain
and review those records that are "reasonably ascertainable." For the purposes of this proposal,
"reasonably ascertainable" information is defined as: (1) publicly available, (2) obtainable from its source
within reasonable time and cost constraints, and (3) practically reviewable. The assessment will include a
review, where available or applicable, of both Environmental and Historical sources.
ENVIRONMENTAL RECORDS REVIEW
The following publicly available listings will be reviewed:
Standard Environmental Records
Federal NPL Site list
Proposed NPL Site List
Delisted NPL Site List
NPL Liens List
Federal CERCLIS List
Federal CERCLIS NFRAP List
Federal RCRA TSD Facilities List
Federal RCRA Generators Lists
Federal CORRACTS list
Federal ERNS list
US Engineering /Institutional Controls Lists
US Brownfields List
EPA Consent Decree List
EPA Record of Decision List
Search Distance (Miles from Boundaries
1.0
1.0
1.0
Target Property
0.5
0.5
0.5
0.25
1.0
Target Property
0.5
0.5
1.0
1.0
City of South Bend - Schalliol
April 21, 2011
Page 3
State Hazardous Waste Site List
State Landfill and /or Solid Waste Disposal Site List
State Leaking UST List
State Registered UST List
State Spills List
State Brownfields List
Indian Sites Lists
Manufactured Gas Sites
ADDITIONAL ENVIRONMENTAL RECORDS
1.0
0.5
0.5
0.25
Target Property
0.5
0.5
1.0
Additional state or local database listings will be reviewed as deemed appropriate. A comprehensive
review of Indiana and /or federal regulatory files is beyond the scope of this Phase I effort, although as
deemed necessary, Wightman Petrie may initiate a Freedom of Information Act Request through the
Indiana Department of Environmental Management (IDEM) Central File Room, or access pertinent
information made available through the Virtual File Cabinet.
POTENTIAL DELAYS
Delays in environmental regulatory responses may delay submittal of our report or necessitate an
addendum. We will notify you if such delays are anticipated.
PHYSICAL SETTING SOURCES
A current United States Geological Survey (USGS) 7.5 Minute Topographic Map will be reviewed to help
evaluate area topographic and surface drainage. At least one additional physical setting source will be
reviewed for information on the geologic, hydrogeologic, hydrologic, or topographic characteristics of the
site.
HISTORICAL USE INFORMATION
The purpose of consulting historical sources is to develop a history of the previous uses or occupancies of
the site, and surrounding area, in order to identify those uses, or occupancies that are likely to have led to
recognized environmental conditions in connection with the subject site.
USES OF THE SUBJECT PROPERTIES
Prior uses of the subject site will be identified from the present, back until to at least the period of initial
development using available "standard historical resources" listed below:
Aerial Photographs
Fire Insurance Maps
Property Tax Files
Recorded Land Title Records
USGS 7.5 Minute Topographic Maps
Local Street Directories
Our proposal does not include a Chain -of -Title search. If others have recently completed a Chain -of-
Title, Wightman Petrie will review the document for potential environmental concerns associated with
prior ownership.
USES OF PROPERTY IN SURROUNDING AREAS
Using available resources, the history and/or general uses of properties in the surrounding area will be
researched at a search distance and time period deemed appropriate given the findings of other
City of South Bend - Schalliol
April 21, 2011
Page 4
portions of the assessment. Complete coverage using local street directories, Sanborn Fire Insurance
Maps and potentially other historical records regarding the prior uses of the subject site and surrounding
properties may be limited, may not be readily available, or may not even exist for purposes of review.
SITE RECONNAISSANCE
The purpose of the site reconnaissance is to observe current conditions at the site and obtain information
indicating the likelihood of environmental concerns with the property.
A reconnaissance will be performed for indications of waste handling or disposal activities that may pose a
hazard to the subsurface environment. We will require access to all areas, to the extent they are not
obstructed by bodies of water, adjacent buildings, or other obstacles. Please note that visual assessment of
the existing ground surface will not be possible should there be the presence of extensive snow coverage.
As such our assessment of the property grounds will be limited in terms of the presence of stressed
vegetation and staining. Unforeseen circumstances notwithstanding, only one (1) site visit will be made.
INTERVIEWS
Interviews will be conducted with knowledgeable persons to obtain direct, personal information regarding
activities and /or operations which may have affected the environmental condition of the site. Selected local
regulatory and /or emergency response officials may also be interviewed regarding knowledge of past or
present environmental problems or emergency responses at the site.
IDENTIFICATION OF DATA GAPS
Depending on the availability of certain resources for evaluating historical property use, previous property
owners (for interview) and other pertinent information; certain "Data Gaps" may be identified within our
Report. Wightman Petrie will make determinations as to the potential impacts such "Data Gaps" have on
conclusions as to the presence or potential presence of recognized environmental conditions.
PHASE I ENVIRONMENTAL SITE ASSESSMENT REPORTING
Upon completion of our site reconnaissance, regulatory database and historical records review, a verbal
summary will be presented. Our written report of findings will include documentation to support the analysis,
opinions and conclusions found in the report, inclusive of referenced sources. If appropriate,
recommendations for additional assessment (Phase II) will be made. Estimated costs and the specific
scope of services for performing any Phase II recommendations will be submitted under separate cover.
Task 2 — Ground Penetrating Radar Survey
Ground Penetrating Radar (GPR) offers the means to detect buried objects that are not otherwise
detectable. In addition to the ability to locate metal objects (i.e., underground storage tanks, drums), GPR
is able to detect non - metallic objects. The system sends radar pulses into the surface, receives, and
processes the reflected energy. Through advanced processing technology, the system calibrates the di-
electric constant of the surrounding material. When the signal is reflected from the material having a
different di- electric constant, the signal is displayed on the screen as an anomaly. Depth can also be
determined by processing the sampling interval and determining the size and comparing relative data to
other objects detected.
Characteristics of underlying soils effect the penetration of the radar through the ground. Sands and
gravel offer the greatest depth penetration and clearest resolution. Whereas, dense saturated clays offer
limited penetration of the radar signal. For purposes of this proposal, Wightman Petrie has assumed a
depth limitation for the GPR of approximately 8 feet below land surface.
Areas of the subject site (exterior only) will be scanned by GPR and delineated using varying interval grid
patterns. Multiple scans in a North -South and East -West direction will be performed utilizing the GPR,
City of South Bend - Schalliol
April 21, 2011
Page 5
looking for anomalies. Any identified anomalies (i.e., utilities, underground storage tanks) will be marked
on the surface using chalk or paint, as appropriate for documentation to others.
Task 3 — Survey for Asbestos - Containing Materials
The purpose of the asbestos survey is identification or elimination of building materials as of Asbestos -
Containing Materials (ACM) in accordance with the National Emission Standard of a Hazardous Air
Pollutant (NESHAP) for Asbestos 40 CFR 61, Subpart M, and 326 IAC 14 -10, Emission Standards for
Asbestos; Demolition and Renovation Operations.
The survey of the property for ACM will begin with a walk- through of the existing structure to document
locations of friable and non - friable materials that may be present. Friable materials are those that can be
pulverized or reduced to powder by moderate pressure, such as spray - applied fireproofing and acoustical
materials, ceiling tiles and most thermal system insulation. Non - friable materials are those that cannot be
crumbled easily, such as resilient floor tiles and cement asbestos (Transited) board. Although emphasis
is on detecting friable materials, the possible presence of non - friable ACM must also be considered, as
during renovation, non - friable materials may be pulverized or otherwise damaged so as to release
asbestos fibers into the air.
The sampling strategy for any suspect material is dependent upon the application, the area of coverage
and the uniformity of the application. In accordance with the United States Environmental Protection
Agency (USEPA) 40 CFR 763.83, Subpart E definitions, there are three types of asbestos - containing
materials (ACM): 1) Thermal System Insulation (TSI), 2) Surfacing Materials (S), and 3) Miscellaneous
Materials (Misc). Thermal System Insulation is material used to prevent heat loss or gain and prevent
condensation, and includes: pipe insulation, valve and fitting insulation, boiler system insulation,
breeching insulation and tank insulation. Surfacing materials are spayed on, troweled on or materials
otherwise applied to a surface and include: acoustical plaster, fireproofing on structural members or
decking, or on surfaces for the purpose of fireproofing. Miscellaneous or "other" materials are those that
are not characterized as TSI or Surfacing Materials, and include: ceiling tile, floor tile, roofing felt, cove
base and associated adhesive or mastic.
Each suspect ACM (i.e., TSI, Surfacing or Miscellaneous material) identified from the initial walkthrough
of the facilities will be placed into a group of similar materials identified as a homogeneous area.
Homogeneous areas are identified as materials of the same type, color, texture and estimated age of
installation. Upon identifying homogeneous areas, representative samples will be collected on a random
basis. The number of samples collected depends upon the type of material (TSI, S, Misc) and the
amount of the material, in accordance with the following, based on OSHA regulations detailed in 29CFR
1926.1001).
Type of Material
Amount
Number of Samples
Surfacing Materials
< 1,000 SF
Minimum of 3 samples
1,000 to 5,000 SF
Minimum of 5 samples
> 5,000 SF
Minimum of 7 samples
Thermal System Insulation
< 6 LF /SF
1 sample required
, 6 LF /SF
Minimum of 3 samples
Misc /Other
Any
Sufficient to determine ACM /Non -ACM
General in accordance with 3/5/7 protocol for
Surface Materials
Notes: LF — Linear Feet, SF — Square Feet
The asbestos - containing material (ACM) survey will be performed by an Indiana Certified Asbestos
Building Inspector. At any time during the survey, the Inspector can elect to assume that a specific
material is asbestos - containing, and thereby forego sampling requirements for that homogeneous area.
Samples, as appropriate, will be collected in general conformance with the procedures outlined in the
Asbestos Hazard Emergency Response Act of 1986 (AHERA).
City of South Bend - Schalliol
April 21, 2011
Page 6
Sample collection will involve extraction /separation of approximately 1 to 10 cubic centimeters of the
suspect material, inclusive of all layers present within the material. Only suspect material samples will be
submitted for laboratory analyses. Samples will be sealed in airtight containers, numbered and labeled,
and forwarded to an approved laboratory for analysis by the EPA - recommended method of Polarized
Light Microscopy PLM, coupled with dispersion staining.
Sampling and analysis of suspect materials is performed in an effort to try and confirm the presence of
asbestos, or eliminate suspect materials as ACM. Elimination of a material as ACM for purposes of
maintenance, renovation or demolition occurs if: 1) the material is visibly non -ACM (fiberglass and
rubberized materials), 2) documentation indicates that the materials used in manufacture are non -ACM,
or 3) sampling and analysis are performed.
According to OSHA Construction Standards, negative analysis for a minimum of three samples is
required to conclusively determine a material as being non -ACM. In addition, all of the samples must be
from the same homogeneous area (color, texture and estimated date of installation). Wightman Petrie
will attempt, through application of our sampling strategy, to make determination of the asbestos content
of any identified homogeneous materials for which sampling is in fact performed (i.e., certain materials
may be assumed to be asbestos - containing).
Task 4 — Demolition Specification Preparation
Prepare and provide the City of South Bend a set of demolition specifications for bidding in order to
demolish the existing structure present at the 306 W. Monroe address (two -story, residential -like structure
with basement). The specifications will include the site demolition and restoration instructions,
instructions on the removal of any environmental items identified in the Phase I Environmental Site
Assessment, Ground Penetrating Radar Survey or Asbestos - Containing Material Survey, as well as any
other special considerations that may have been noted or identified during the inspection process (i.e.,
solid waste accumulations, household hazardous wastes, etc.). The Ground Penetrating Radar Survey
will provide information /data as to the presence, location and lateral extent of any underground utilities or
other buried obstructions as additional information for consideration to potential bidders, in the avoidance
of any delays or problems with the demolition of the structure.
Task 5 — Site Layout and Construction Design Services
Based upon the information gathered during the various field investigations and previously completed land
survey, Wightman Petrie will provide (1) one conceptual layout of the parking lot and associated walkways
for client approval. We have assumed that existing site engineering and utility base information will be
provided by the City of South Bend, and that a Rule 5 Permit and processing of documentation through the
St. Joseph County Soil and Water Conservation District will not be necessary based upon the limited size of
the parcel (less than 1 -acre disturbed). Once a design has been approved, Wightman Petrie will prepare
the Construction Documents and related professional services and will provide, but will not be limited to, the
following:
1. Dimension Plan indicating pavement types and locations, site features, site amenities,
horizontal dimensions /layout.
2. Grading Plans
3. Utility Plans
4. Erosion Control Plans
5. Landscape Planting Plan and Details
6. Site Construction Details — Various details to support the development of the Construction
Documents will be provided.
The site plan will be subject to the City of South Bend's project review process. Should any Engineering
or Design services outside of the stated Scope of Services be requested by the City of South Bend; such
City of South Bend - Schalliol
April 21, 2011
Page 7
services will be considered as Additional Services and be subject to billing as a Change Order item (with
City of South Bend's prior approval)
COST INFORMATION AND SCHEDULE
We propose to perform the Scope of Services, as presented herein for the ESTIMATED FEES indicated
below:
Task 1 - Phase I Environmental Site Assessment
$1,500.00
Task 2 - Ground Penetrating Radar (assume % -day)
$ 700.00
Task 3 - Asbestos Survey (Up to 20 sample submitted)
$ 700.00
Task 4 - Demolition Specification Preparation
$4,750.00
Task 5 - Site Layout and Construction Design Services
$5,850.00
TOTAL PROJECT ESTIMATED FEES $13,500.00
Our Phase I Assessment Report, Ground Penetrating Radar Survey and Asbestos Containing Material
Survey will be submitted within three weeks of receipt of Authorization to Proceed. A verbal summary will
be made upon completion of the site reconnaissance effort and review of the regulatory database search
information. Wightman Petrie is prepared to use the information gathered as part of the aforementioned
surveys for the completion of a series of Bid Specifications within 45 days following the completion of such
surveys. The process of preparing a Site Layout and Construction Design Services is an ongoing and
relatively independent task from that of Tasks 1 through 4. As such, the schedule for preparation of Site
Layout and Construction Design Services will be performed concurrently with that of the other tasks.
In summary, it is our understanding that the City of South Bend is seeking to commence with the demolition
of the structure at 306 W. Monroe Street (former Michiana Lock & Key facility) upon the date at which the
City of South Bend physically takes ownership of the property (90 days from the date of sale, estimated as
April 1, 2011).
AUTHORIZATION
Wightman Petrie appreciates the opportunity to be of service on this project, and is prepared to
commence work immediately upon your acceptance of this proposal. Should you have any questions or
require additional information, please contact me at (574) 232 -4388. If acceptable, please execute the
proposal by signature, where indicated, and return a copy to my attention at (574) 232 -4333.
Since y,
Conley B. Phifer, CHMM
Environmental Department Manager
I: \Proposals \City of South Bend \306 W. Monroe South
Bend PHI and Demo-4-21 -1 1.doc
City of South Bend - Schalliol
April 21, 2011
Page 8
This proposal (PROFESSIONAL CONSULTING SERVICES AT THE FORMER MICHIANA LOCK &
KEY FACILITY LOCATED AT 306 W. MONROE STREET, SOUTH BEND, INDIANA FOR ESTIMATED
FEES OF $13,500) is hereby accepted and authorization to proceed hereby granted:
Accepted By:
Printed name and title:
Business name:
Billing address:
Billing /account manager:
Phone No.:
Date:
Fax No.: E -mail:
I: \Proposals \City of South Bend Wichiana Safe and Lock PHI Demo Services-4-21-1 1.doc