Loading...
HomeMy WebLinkAbout6C(2) Proposal for Supplemental Phase II AssessmentCr C ( �_) Community & Economic Development 1865 r 1200 County -City Building, 227 West Jefferson, South Bend, Indiana 46601 -1830 Phone 574/235 -9371 Fax 574/235 -9021 To: Redevelopment Commission From: David Relos, Economic Development Planner Subject: Professional Services Agreement — Phifer Environmental Services Supplemental Phase II Environmental Site Assessment 1521 / 1527 S. Kendall St Date: November 02, 2010 The attached Professional Services Agreement is a proposal from Phifer Environmental Services for additional site investigation at 1521 / 1527 S. Kendall St. A Phase I was completed by Phifer Environmental for this property on June 21, 2010, which revealed certain Recognized Environmental Conditions. A Phase II was recommended, approved by the Commission on July 23, 2010, and completed on October 12, 2010. The Phase II revealed Tetrachroethylene in the ground water at the two most eastern of the four sample sites on this property, which over the years has been a car repair and body shop. Tetrachroethylene is a chemical traditionally used in the dry cleaning business. Because historically there was a dry cleaner a half block to the south, and a Laundromat directly to the south of this property, it is suggested that further analysis be done. This analysis will consist of five geoprobes to be installed around the perimeter of this property, to collect water and soil samples. The water samples will be tested to try to determine from which direction the Tetrachroethylene is coming from, and that this site is not the source of contamination. Total project services cost is a not to exceed of $5,175. Staff requests approval of this Professional Services Agreement, to allow a Supplemental Phase II Environmental Site Assessment to be completed for this property. What We Do Today Makes A Difference! f4( October 25, 2010 Mr. David Relos, Economic Development Planner Community and Economic Development City of South Bend 1200 County -City Building 227 West Jefferson Boulevard South Bend, Indiana 46601 Subject: Proposal for Supplemental Phase II Environmental Site Assessment 1521/1527 Kendall Avenue South Bend, Indiana PES Proposal #P10 -139 Dear Mr. Relos: Phifer Environmental Services, LLC is pleased to provide the following Proposal for Supplemental Site Assessment Services associated with general area of 1521/1527 Kendall Avenue. The following presents a review of the background information leading to the recommendation for supplemental environmental services, as well as the proposed scope of such recommended services, project schedule and estimate of costs. PROJECT INFORMATION Phifer Environmental Services, LLC. recently completed a Phase I Environmental Site Assessment of the property known as 1521 and 1527 Kendall Avenue, in South Bend, Indiana (June 21, 2010, PES Project 10 -021). Identified Recognized Environmental Conditions focused on historical auto body repair (including historical painting) and current auto service /repair operations have a potential for environmental impact to surface and subsurface soils as a result of poor waste management practices (waste paints, waste oils, waste antifreeze, waste solvents /degreasers). The presence of waste oil pools on the concrete in close proximity to floor drains, stained soils in the area of waste oil containers, as well as other stained soils in the rear fenced area were all indications of poor management practices. Based upon the aforementioned, PES recommended a Phase II Environmental Site be undertaken for the purpose of assessing the extent to which, if any, the automotive repair and maintenance activities conducted at the subject site may have potentially impacted the subsurface environment. Accordingly, the City of South Bend Redevelopment Commission, during its meeting of June 23, 2010 authorized Phifer Environmental Services to perform the recommended Phase II Environmental Site Assessment. Such assessment involved the installation of four Geoprobe soil borings across the subject site. One of the borings 9GP -1) was established in the area of oil staining at the southwest corner of the building (resultant of poor transfer of waste oils to drums). A second exterior boring (GP -2) was established in the adjacent (north) vacant lot (former residential), as a down gradient location. The remaining two borings (GP -3 2502 Lincoln Way West P.O. 430 Mishawaka, IN 46546 (574)968 -7191 (574) 255 -4699 and GP -4) were established adjacent to the interior floor drains around which pooling of oil had been identified. Field screening, involving the use of a photoionization detector, as well as visual and olfactory observations, did not readily identify the presence of impacted soils within the soil profile of any of the boring locations. However, at least one soil sample was submitted for laboratory analysis of High End Organics and Volatile Organic Compounds (typically the depth interval of between 2 feet to 4 feet was submittal as the most likely to be impacted as a result of surficial and /or drain introduction). In addition, upon encountering the saturated zone (water bearing depth), each of the borings were converted into a temporary well for the collection of a groundwater sample (analysis of Volatile Organic Compounds). Results of the Phase II Environmental Site Assessment (Report dated October 11, 2010, PES Project #10 -044) identified the presence of High End Organics in the soil sample collected in the area of the waste oil drums (2 -feet below land surface) at a level of 75.5 mg /kg. The current RISC Residential criterion for High End Organics is 230 mg /kg. None of the other soil samples submitted from any of the soil borings were reported with either High End Organics or Volatile Organic Compounds above laboratory detection limits. With respect to the groundwater samples collected and submitted for analysis of Volatile Organic Compounds; the presence of Tetrachloroethylene (also known as PCE) was reported for location GP -2 (0.015 mg /L) and GP -3 (0.0116 mg /L). The RISC Residential criterion for Tetrachloroethylene, which is commonly associated with dry cleaning operations, has been established as 0.005 mg /L. We note that the RISC Industrial criterion has been established as 0.55 mg /L; however current RISC guidance stipulates that use of the Industrial Default Closure Values requires the deed attachment of a Restrictive Environmental Covenant that prohibits the use of groundwater. With the exception of Dibromochloromethane reported for the GP -3 groundwater sample (attributed to the presence of a chlorinated municipal water line), no other Volatile Organic Compounds were reported for any of the groundwater samples. Given that 1) Tetrachloroethylene was not detected in any of the soil samples submitted for analysis, 2) that there were no indications of highly impacted zones as would have been noted via the field screening process; and 3) the locations of GP -2 and GP -3 were the easternmost of the four boring locations, with groundwater flow in the area being to the north /northeast; IDES concluded that the likely source of the Tetrachloroethylene was not the commercial garage, but more likely associated with historical off -site sources. Such off -site sources include a former adjacent self - service Laundromat (potential use of coin operated dry cleaning machines) and several historical dry cleaning facilities having been located along Indiana Avenue, to the south of the subject site (up gradient). IDES further concluded that a Supplemental Environmental Site Assessment would be necessary to further delineate the potential source of Tetrachloroethylene in the area. Accordingly, the following sections present our approach toward conducting the Supplemental Environmental Site Assessment, projected costs and a tentative schedule for completion. PROPOSED SCOPE OF SERVICES Soil Sampling via Geoprobe Methodology We note that the City of South Bend currently owns a former residential property located to the southwest of the commercial garage (up gradient), the former residential property to the north of the commercial garage, as well as the former public park, located across Kendall Street from the subject site (side gradient to down gradient). Other publically accessible areas in close proximity include alleyways to the immediate west and south of the subject site (side gradient and up gradient). Using Geoprobe methodologies (small track mounted hydraulically driven sampling probe) soil samples from a total of five locations. One soil boring (GP -5) is proposed for the common alleyway to the west of the subject site. Two additional soil borings are proposed for the residential lot to the southwest of the site. One of the borings (GP -6) would be located within the front yard, along Indiana Avenue; the second (GP -7) being located in the rear yard, along the eastern property boundary of the lot. The fourth boring (GP -8) will be established within the east /west alleyway, near the intersection of Kendall Avenue. The final boring (GP -9) is proposed to be located within the public park area to the east of the subject site, across Kendall Avenue. For each of the Geoprobe boring locations, discrete soil samples will be collected at 4- foot intervals throughout the soil profile to a depth of 20 feet below ground surface, or until saturated soil conditions are encountered. Each soil sample interval will be screened for the presence of volatile organics by placing a portion of the soil sample into a plastic bag, allowing time for equilibration, and insertion of a photo ionization detector (PID) probe to observe a reading of "total VOCs" in parts per million (ppm). All data associated with the field screening of VOCs will be recorded for future reference (Soil Boring Logs). In addition, a portion of each discrete sampling interval will also be collected for submittal to the laboratory. PES proposes to submit two soil samples from each of the five boring locations based on the PID field screening results and /or other indications of the presence of potential contamination (visual or olfactory). In the event that field screening with a PID, visual or olfactory observations do not indicate the presence of contamination; the two depth intervals immediately above the soil /groundwater interface will be submitted for laboratory analysis. Each of the soil samples selected for laboratory analysis will be analyzed for the presence of Volatile Organic Compounds (VOCs). PES will utilize IDEM guidance Terra -Core Methods to collect soil samples from each discrete sampling interval for the analysis of VOCs. All soil samples will be labeled, packed on ice and forwarded to the laboratory under chain -of- custody procedures. Temporary Geoprobe Well Installation for Groundwater Sampling PES proposes to convert each of the five Geoprobe soil borings to temporary wells with insertion of a Geoprobe groundwater sampling device, which allows for the extension of a stainless steel slotted screen for collection of a groundwater sample from the point at which the saturated or water - bearing zone is encountered. For this proposal, PES has assumed that the water - bearing zone will be encountered within 20 -feet of land surface. Once installed, each temporary well would be purged until such time as the water discharge becomes relatively free of solids or until at least three gallons of water have been removed. PES proposes that groundwater from each of the temporary wells be analyzed for VOCs. Each groundwater sample will be appropriately labeled, packed on ice, and forwarded to the laboratory (priority overnight delivery) under chain -of- custody procedures. PES will plug the boreholes /wells with bentonite once soil and groundwater sampling activities have been completed. Reporting Upon receipt of the laboratory analyses, data will be reviewed and tabularized. Comparison of the data for each respective chemical constituent will be made to the Risk Integrated System of Closure (RISC) Default Closure Values for Residential and Industrial /Commercial Properties. Upon completion of the initial data review, a "Letter Report" will be prepared which presents the sample collection and analytical methodologies used during the field phase of the assessment. Copies of the sample location maps, tabulated data and comparison to RISC Default Closure Values will also be incorporated. Recommendations for any additional assessment activities will be made for review and comment. SCHEDULE PES proposes to commence site investigation activities within one week of receipt of notification to proceed (depending on weather, utility clearance and Geoprobe availability). Upon mobilization, we anticipate completion of the Geoprobe sampling requiring one day. Laboratory analyses will be completed by Pace Analytical on standard one -week turnaround from receipt by the laboratory. Our initial discussion of results will occur within one day of receipt of laboratory analytical results. Our written "Summary Letter Report" will be submitted within one -week of the initial conference. COST ESTIMATE An ESTIMATED COST for Phase II Environmental Assessment Services with respect to the Baseline Environmental Assessment is presented as follows: Field Engineering Services /Project Management $ 900 Geoprobe Rental (assumes 1 -day @ $1,400 /day, including mobilization) $1,400 Equipment Rental and Expendable Sampling Supplies $ 300 Laboratory Analysis: 10 soil samples for % Moisture @ $10 /sample $ 100 10 soil samples for analysis of VOCs @ $85 /sample $ 850 5 groundwater samples for analysis of VOCs @ $85 /sample $ 425 Terra Core Sampling Kits for collection of soil samples (20 kits @ $15 /kit) $ 300 Reporting 900 ESTIMATED COST $5,175 Please note that this ESTIMATED COST should be considered a Project Maximum, which PES will not exceed without prior approval. However, should the scope of services require modification (i.e., additional borings) based upon field conditions and /or circumstances that would not have otherwise been anticipated, PES will notify the client of such "changed conditions" and resultant cost implication to the project. LIMITATIONS /QUALIFICATIONS The sampling and testing of soil, groundwater and /or other materials not specifically identified in this proposal is beyond the scope of services for this project. Cost estimates for our proposed services have been prepared based on the following assumptions: • PES will have unlimited access to the site during daylight hours; • Interior areas identified for borehole installations will be cleared to allow for sufficient access for equipment • No subsurface obstructions (buried utilities or fill debris) will interfere with our work; • Sufficient access /clearance will be provided for exterior Geoprobe locations; • Groundwater will be encountered within 30 -feet of ground surface; • Inclement weather will not interfere with the completion of our field work; Soil cuttings and purge waters will be returned to the boring from which they were generated, with the remainder of the boring filled with bentonite pellets to land surface. This Supplemental Environmental Site Assessment should be considered as a "tool" in the evaluation of the subject site relative to the potential presence of contaminants, and does not necessarily fulfill Indiana Department of Environmental Management (IDEM) guidelines for delineation of contaminants identified within soil or groundwater. AUTHORIZATION Phifer Environmental Services, Inc. appreciates the opportunity to be of service on this project. Should you have any questions or require additional information, please contact me at (574) 968 -7191. Please acknowledge acceptance of this proposal by signature, where indicated, as authorization for PES to proceed. Sinc ly, 'Conley B. Phifer, CHMM Phifer Environmental Services, LLC M , )Pt 400 .'40" PROPOSAL ACCEPTANCE Proposal for Supplemental Environmental Site Assessment (Proposal #P10 -139), dated October 25, 2010, at 1521/1527 Kendall Avenue, in South Bend, Indiana is hereby accepted and authorization to proceed in accordance with the specific limitations /qualifications is hereby granted. Signature (Authorized Representative) Title Representing Point of Contact Date Telephone If accepted, please forward executed copy to Phifer Environmental Services, LLC at (574) 255 -4699. Return e-mail (conley @phiferenv.com) with proposal acknowledgement is also acceptable. 2502 Lincoln Way West P.O. 430 Mishawaka, IN 46546 (574)968 -7191 (574)255 -4699