Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Opening of Proposals - MPAC Water Softener System - Culligan Water
........... ........... Morris Performing Arts Center Department of Venues, Parks & Arts South, Bend, I. C� IN OF SOUTH SEND VENUES PARKS 6 AR111"S John M Murphy 11 Culligan Water Commercial & Industrial Sales 56861 Ferrettie Ct Mishawaka, IN 465,45 574-276-5369 lihaw 2b'Y2bgvL When the prospective Contractor is unable to certify to any of the statements below, it shall attach an explanation to this Affidavit, CONTRACTOR'S NON -COLLUSION AND NON -DEBARMENT AFFIDAVIT, CERTIFICATION REGARDING INVESTMENT WITH IRAN, EMPLOYMENT ELIGIBILITY VERIFICATION, NON-DISCRIMINATION COMMITMENT AND CERTIFICATION OF USE OF UNITED STATES STEEL PRODUCTS OR FOUNDRY PRODUCTS (Must be completed for all quotes and bids. Please type or print) STATE OF } } SS: COUNTY ) The undersigned Contractor, being duly sworn upon hislherlits oath, affirms under the penalties of perjury that: 1. Contractor has not, nor has any other member, representative, or agent of the firm, company, corporation or partnership represented by him, entered into any combination, collusion or agreement with any person relative to the price to be bid by anyone at such letting nor to prevent any person from bidding nor to induce anyone to refrain from bidding, and that this bid is made without reference to any other bid and without any agreement, understanding or combination with any other person in reference to such bidding. Contractor further says that no person or persons, firms, or corporation has, have or will receive directly or indirectly, any rebate, fee, gift, commission or thing of value on account of such sate; and 2. Contractor certifies by submission of this proposal that neither contractor nor any of its principals are presently debarred, suspended, proposed for debarment, declared ineligible, or voluntarily excluded from participation in this transaction by any Federal department or agency; and 3. Contractor has not, nor has any successor to, nor an affiliate of, Contractor, engaged in investment activities in Iran. a. For purposes of this Certification," lr&W' means the government of Iran and any agency or instrumentality of Iran, or as otherwise defined at Ind. Code § 5-22-I6.5-5, as amended from time -to -time. b. As provided by Ind. Code § 5-22-16.5-8, as amended from time -to -time, a Contractor is engaged in investment activities in Iran if either. Contractor, its successor or its affiliate, provides goods or services of twenty million dollars ($20,000,000) or more in value in the energy sector of Iran; or ii. Contractor, its successor or its affiliate, is a financial institution that extends twenty million dollars ($20,000,000) or more in credit to another person for forty-five (45) days or more, if that person will (i) use the credit to provides goods and services in the energy sector in Iran; and (ii) at the time the financial institution extends credit, is a person identified on list published by the Indiana Department of Administration. 4. Contractor does not knowingly employ or contract with an unauthorized alien, nor retain any employee or contract with a person that the Contractor subsequently learns is an unauthorized alien. Contractor agrees that he/she/it shall enroll in and verify the work eligibility status of all of Contractor's newly hired employees through the E»Verify Program as defined by I.C. 22-5-1.7-3. Contractor's documentation of enrollment and participation in the E-Verify Program is included and attached as part of this bidtquote; and S. Contractor shall require his/her/its subcontractors performing work under this public contract to certify that the subcontractors do not knowingly employ or contract with an unauthorized alien, nor retain any employee or contract with a person that the subcontractor subsequently learns is an unauthorized alien, and that the subcontractor has enrolled in and is participating in the E-Verify Program. The Contractor agrees to maintain this certification throughout the term of the contract with the City of South Bend, and understands that the City may terminate the contract for default if the Contractor fails to cure a breach of this provision no later than thirty (30) days after being notified by the City. 6. Persons, partnerships, corporations, associations, or joint venturers awarded a contract by the City of South Bend through its agencies, boards, or commissions shall not discriminate against any employee or applicant for employment in the performance of a City contract with respect to hire, tenure, terms, conditions, or privileges of employment, or any matter directly or indirectly related to employment because of race, sex, religion, color, national origin, ancestry, age, gender expression, gender identity, sexual orientation or disability that does not affect that person's ability to perform the work. In awarding contracts for the purchase of work, labor, services, supplies, equipment, materials, or any combination of the foregoing including, but not limited to, public works contracts awarded under public bidding laws or other contracts in which public bids are not required by law, the City, its agencies, boards, or commissions may consider the Contractor's good faith efforts to obtain participation by those Contractors certified by the State of Indiana as a Minority Business ("MBE") or as a Women's Business Enterprise ("WBE") as a factor in determining the lowest, responsible, responsive bidder. In no event shall persons or entities seeking the award of a City contract be required to award a subcontract to an MBE/WBE, however, it may not unlawfully discriminate against said WBE/MBE. A finding of a discriminatory practice by the City's MBE/WBE Utilization Board shall prohibit that person or entity from being awarded a City contract for a period of one (l) year from the date of such determination, and such determination may also be grounds for terminating the contact for which the discriminatory practice or noncompliance pertains. 7. The undersigned contractor agrees that the following nondiscrimination commitment shall be made a part of any contract which it may henceforth enter into with the City of South Bend, Indiana or any of its agencies, boards or commissions. Contractor agrees not to discriminate against or intimidate any employee or applicant for employment in the performance of this contract with privileges of employment, or any matter directly or indirectly related to employment, because of race, religion, color, sex, gender expression, gender identity, sexual orientation, handicap, national origin or ancestry. Breach of this provision may be regarded as material breach of contract. 1, the undersigned bidder or agent as contractor on a public works project, understand my statutory obligations to the use of steel products or foundry products made in the United States (I.C. 5-16-8-1). 1 hereby certify that I and all subcontractors employed by me for this project will use steel products or foundry products made in the United States on this project if awarded. I understand I have an affmative duty to notify the City in my bid that any proposal does not include the use of steel products or foundry products made in the United States, I understand it is my sole obligation and responsibility to provide a justification to the City, subject to review and approval, why the cost of United States made steel or foundry products is unreasonable. Prior to award and upon submission of bid which does not use steel products or foundry products made in the United States, the City, through its director of public works, shall make a determination if the price of United States made steel or foundry is unreasonable. I understand that violations hereunder may result in forfeiture of contractual payments. I hereby affirm under the penalties of perjury that the facts and information contained in the foregoing bid for public works are true and correct, 4A 0 r Doted this day of 20 EM - ka ct&!dc ' CoM/B Signature of Contractor/Elidder or Its Ageat Printed Name and Title Subscribed and swom to before me this Wday of My Commission Expires a."J ........... ... Notary Public County of Residence Morris Performing Arts Center Dept. of Venues Parks & Arts Water Softener System Project #1026-2017 December 12, 2017 Prepared by: John Murphy Culligan of Michiana 56861 Ferrettie Court Mishawaka, IN 46454 574-276-5369 Cell 574-289-6371 Office Table of Contents Formal Bid Additional Comments Acceptance Form Power Point Slides System Specifications Plumbing Diagram Electrical Diagram Dry Salt Storage Warranty Date: 12/12/2017 Prepared By: John Murphy Culligan of Mishawaka 56861 Ferrettie Ct. Mishawaka, IN: 46545 574-276-5369 jmurphy@heywaterman.com RE: Water Softener System Project #1026,-2017 Culligan Equipment/Services: 121217-JM55 Quoted To: Morris Performing Arts Center Dept. of Venues Parks & Arts South Bend, IN 46616 Qty DescOptlon Price 3 CTM-1 50-PF Triplex Softeners with a 3 Year Warranty I Brine System with 24" x 50" Tank, 3/4" Valve and 900 lb Salt Capacity 2 Culligan CBI; Standard Communication Cable 3 CTM Plumbing Adapter, 2" NPT, Inlet/Outlet 900 Salt Set up, Installation, Freight, Parts and Materials included Equip meat and Services Sub Total: I have read and agree to the terms and conditions above and attached. Accepted: Signature Accepted: Printed Purchase Order#: Date: Title: WERM Acceptance ate: 12/12/2017 Quote: 121217-JM55 Prepared By: John Murphy Culligan of Mishawaka 56861 Ferrettie Ct. Mishawaka, IN 46545 574-276-5369 imuirDhvQ1).he watermain.com RE: Water Softener Project #1026-2017 Quoted To: Morris Performing Arts Center Dept. of Venues & Parks South Bend, IN Comments and Exceptions taken to Culligan Terms and Conditions Tax is not included. If exempt, we will need proper paperwork. I have read andl agree to the terms and conditions above and attached. Initial Initial Initial Accepted; 11 would like to purchase the units and have Culligan Deliver, Set & Fill the units. I would like the Ilease Option (term to be initialed and signed for Leaf Financial) I would like to have Culligan train, the end user for an additional $250 Signature Accepted: Printed Purchase Order #: Date: Title: ADDITIONAL COMMENTS Installation: • Installation is included and will be performed by Culligan. Culligan will provide equipment delivery and will set equipment in place. Culligan will attach inlet, outlet and drain to supplied connections. Electrical service must also be available for connection to equipment. • Installation service may be arranged through Culligan. Please schedule installations 7 days in advance. • Installation, as quoted, is scheduled during normal business hours (8 AM to 5 PM) • Please contact me/us directly for more information. Start-up and Training: Start-up and training is available upon request. Salt Delivery: • The initial salt fill shall include 900 pounds of salt delivered by Culligan to the job site. • Culligan offers routine salt delivery. Our representative will deliver and load the required amount of manufacturer recommended salt into the unit. Culligan will also perform a 10-point check of the unit each time salt is delivered. Pricing varies with volume usage. • Culligan can provide you scheduled salt delivery. Please see me for a salt quote. Submittals: • Provided upon your request, • Product submittal documents, subject to specifying engineer approval, will be made available upon your request. Please indicate the number of submittals required. • Product submittal documents will be made available upon receipt of purchase order contingent upon approval by the specifying engineer. Please indicate the number of submittals required. Maintenance, Service and Repair • Regular service hours are 8 AM to 5 PM Monday through Friday. Emergency service is available 24 hours a day, seven days per week. Emergency service rates apply. • Operational, maintenance and replacement requirements are essential for this product to perform properly. Your system requires routine maintenance consisting of Enclosures: Culligan Terms and Conditions 7' Customer Proposa.- LEAF Custom Quote Prepared For: 4 Morris Performing Arts Ctr 0 Dept Venues Parks Art 211 Dr MLK Dr N # South Bend, IN 46601 0 Ptease check the desired payment. Comp'"I'Name 160111tro =1011074 Contact Emall'Addte$5 Phone Fipa�nced mount: Term: ZMEMMM 12, ❑ $ 9'24.62 24 ❑ $ 482.72 36 ❑ $ 339,17 48 ❑ $ 268.59 60 El $ 225.48 End of lease optiom 1) Purchase the equipment for $1 1. At monthly payments calculated above are net of applicable taxes" such taxes All be referenced In the lease and the responsibility of the lessee. I Your Proposal is an expression by LEAF Capital Funding, LLC. of its interest in pursuing a transaction on the general terms and conditions outlined above. The Proposal is not Intended to and does no create any binding legal obligation on the part of either party. THE PROPOSAL IS NOT, AND IS NOT TO BE CONSTRUED AS, A COMMITMENT BY LEAF OR ANY RELATED ENTITY TO PROCEED WITH ANY LEASE TRANSACTION. LEAF Capital Funding, LLC. All not be obligated to proceed AN any lease transaction until the satisfactory completion of its credit, legal and investment approval process. The terms and conditions of the Proposal shall be superseded by and shall no longer be effective upon the execution and delivery of final legal documentation with respect to the proposed transaction. This proposal is for now equipment only. $1.00 Purchase Option The $1 purchase option transfers the ownership of the equipment to you at the end of the lease term. The lease payments must be deducted as a capital expense- (depreciable asset). This option protects your cash reserves, helps you manage your cash flow and simplifies budgeting with fixed monthly payments. This option is best for equipment that you intend to keep more than 5 years. * Always consult your tax andlor accounting advisor; LEAF Capital Funding, LLC. does not intend and provision herein to constitute tax or accounting advice. To accept the Proposal, check the desired monthly payment above, sign in the space below Ef611-5786 and fax to: Accepted by: Date: Any questions call: Sherri Heathman 877-895-0191 267-675-5786 Sheatman@LEAFnow.com OLEAF CREDIT APPLICATION Contact Sherri Heathman Phone 877-895-0191 Pnv 7R7-R7.rA7RR TFIRMILEASE PAYMENT SCHEDULE: Term (Months) Security DeposillAdvance payment (Check One Only) Lease Enurcriase Caption (Check One Only) i I ❑ Security Deposit (s): $ [,� Advance Payment (s): ❑ FMV ❑ $t ❑ Other CUSTOMER a Lessee Name Lessee P one Number E-mail Monts Performing Arts Ctr Lessee Address 211 Of MLK Dr N South Bend, IN 46601 Signer Name Tax ID Nature of �+t€e Bus. ,.:£r Started REFERENCES Style of Business: ❑ Corporation El Partnership Annual revenue: ©Over gt million © Sde Proprietor ❑ P.C. ElL.L.C. ❑ tinder $1 million Bank Reference Account No. Bank Phone Bank Contact No. Trade Ref- Phone No. Account No. Contact 13ERSONAL INFORMATIONON a• a- OR • Name Name Title Social Title social Security No. Security Address Address County State County Zip State Zip AUTHORIZATION e un ersigne n i ua s who is ei er a P nc pa , So a ropdetor, or Persona uaranlor of the Credit scant, recogn rang al s ar of R IVI ua ere 3t IS ory may e a ac or m e eva ua ono a cre It story a t e Applicant or in the evaluation of his or her personal guaranty, if applicable, hereby consents to and authorized the use of a consumer credit report on the undersigned ltndividual(s) by the above named business credit grantor, from time to lime as maybe needed, in the initial credit evaluation and subsequent review processes. Ifwe stand advised that the Advance Payment or Security Deposit is not refundable unless this application is rejected by Lessor. Partner, Proprietor or Guarantor Partner, Proprietor or Guarantor .X ix `ar application for business credit is denied, you have the tight to a written statement of the specific reasons for the denial. To obtain the statement, please cal (f)W)819-5556 Wthin 60 days front the dale you are noffed of our ton. We v+ill send you a written statement of reasons for the denial vithin 30 days of receiving your request for the statement. NOTICE: The Federal Equal Credit Opportunity Act prohibits creditors from discriminating against credit �'plicania on the basis of race, color, religion, national origin, sex, martial status, age (provided the applicant has the capacity to enter into a binding contract); because all or part of the applicant's income derives from any pubic assistance program; or because the applicant has in good faith exercised any right under the Consumer Credit Protection Act. The federal agency that administers compliance with the lawconceming the creditor is the Federal Trade Commission, Equal Credit Opportunity, Washington, D.C. 20560. Please Fax to: 267-675-5786 Or Email to: Sheatrnan cALEAFnow.com 'rable 1 . CTIVI Flow Specifications Softener Model I 120K ISOK 600K Continuous Minimum _60K _1_", _j 5 _21OK (gpm) Continuous maxjm= 45 (gpin), Service Continuous @ 15 psi 69 max. pressure loss Peak a 26 psi niax, 76 . ..... . , --pres8urelGss Suggested Progressive Flow 46 Trip Point (gpm)2 8 Backwashl Fast Rinse (gpm) Brine Draw (gpm) Drain Slow Rinse (gpm) 1,601 Refill (gpm), Standard 1;25 --_L__ [Fast Refill]3 The system I have designed for you is a Triplex 2" 150,000 grain Progressive Flow Culligan Top Mount (CTM) Flow rates for this are 5 gpm min, 1.35 gpm continuous & 177 gpm max. This design will work well for minimal daily flow, as well as peak times, ** We are proud to offer you brand new technology, with superior features. The older model Fleck 2900 will give you 42 gpm with each unit, with a max of 55 gpm. The older model Fleck 2900 also is made of brass, which is not permitted to be used in the future. The older model Fleck 2900 does not hold the NSF certification that we have been awarded. The older model Fleck 2900 has a 1 year warranty, versus our 3 year. Softener System Selected is: CT'M-150-PF Multi -tank System The CTM will Provide (Each Unit): Continuous Flow, gpm 59 @ 15 psi loss It Peak Flow, gpm 76 @ 25 psi loss Min. Recommended Flow, gpm :3.5 Resin Quantity, ft3 5 Unit Capacity, kgr 148 @ 75 lbs Salt Maximum Capacity, kgr 150 @ 75 Ibs Salt Minimum Capacity, kgr 100 @ 30 lbs Salt Tank Size, in. 18x65 Tank Area, ft' 1.77 Freeboard, in. 23 Regeneration Data for Recommended Brine System (Each Unit)* Brine Tank Size, in. Max. Salt Load, Ilbs Number of IRegens/Salt Fill Salt Usage, lbs/Regen System Requirements: Operating Press., psi Operating Temp., *F Pipe Conn, in NPT... Inlet, in. Outlet, in. Drain, in. Shipping Weight, lbs... Duplex Triplex Quad Operating Weight, Ibs, Duplex Triplex Quad Overall Dimensions, in.... Width x Height x Depth Duplex Triplex Quad 2440 6010 8 :75 35-125 40-120 2 or 1.5 2 or 1.5 1.5 881 1304 1950 2116 2779 3687 80 x 85 x 20 108 x 85 x 20 136 x 85 x 20 �Backwash Flow Req'd, gpm 8 Recond. Water Req'd, gals 272 Total Regen Time, min. 76 Voltage : 120 Volts AC, 50/60 Hz, 1 Ph Full Load, Amps : < 1 Generated by the Culligan CAARD Program Page 1 of 11 r, y, 1.0 SCOPE Culligan Top Mount Softener Engineer's Specification 1.1 Provide as indicated a vertical pressure type water softener system complete with pressure vessel, softening resin, control valve, brine maker and electronic controller. The system will be of an approved design as fabricated by a manufacturer regularly engaged in the production of water treatment equipment. All equipment and material will be supplied in compliance with the specifications as intended for a complete and operational system. 11.2 Qualified manufacturers of water softener equipment must be engaged in the manufacture of this type of equipment for a period of not less than fifty (50) years, Acceptable manufacturers are Culligan International Company or the Engineer's approved equal. 1.3 Qualified manufacturers will have the entire softener certified as a system, to NSF/ANSI 61, NSFIANSI 372, CSA 483.1, UL/CUL and CE. 2.0 GENERAL DESCRIPTION 2A The system specifications are based on Culligan International model CTM-150-PF Muli,-tank System configured with either Timeclock, Water Meter or an Aqua Sensor device. The purpose of the Culligan International Culligan Top Mount Triplex automatic water softener will be to remove mineral hardness from a known water supply to a level not to exceed 17.1 mg/I, as determined by an accepted ASTM or EDTA test method, when the system is operated in accordance with the operating instructions. The systems performance will be capable of a peak flow rate of 76 gpm per online tank for sustained periods of 90 minutes with a pressure drop of 25 psi, rMLI DI ;KIL111 III VI ;W[C]LI 107-11% 3.1 INFLUENT WATER ANALYSIS N/A 3.2 DESIGN PARAMETERS (Each Tank System) Normal System Flow & Pressure Drop :59 gpm @ 15 psi Maximum System Flow & Pressure Drop 76 gpm @ 25 psi Backwash/Rinse Flow 8 gpm Backwash Volume 272 gallons nominal Daily Water Usage 5000 Operating Temperature Range 40-12,0 OF Operating Pressure Range (System) 35-12,5 psi Electrical Requirements 120 Volts AC, 50/60 Hz, 1 Ph 3.3 EFFLUENT WATER QUALITY : < 1 GPG HARDNESS (ASTM soap test method) Page 1 of 5 4.0 EQUIPMENT SPECIFICATIONS 4.1 SOFTENER TANK(S) Each softener tank shall be 18 in. in diameter. The overall tank height (less base) shall be 65 in., sufficient to allow for a proper freeboard space above the resin bed for adequate expansion of the resin during backwashing. 4.1 A Tank Construction Tank(s) shall be manufactured of polyester reinforced by a continuous roving glass filament overwrap. The top opening will be 4"-8 UN threaded and the tank bottom will be supported on a molded structural base, 4.1.2 Access Openings (Optional) Each tank will be equipped with openings for mineral filling and periodic inspection. 4.2 INTERNAL DISTRIBUTION 4.2.1 The upper distribution system shall be of the single point diffuser type to dispense water laterally to avoid channeling within the resin bed. 4.2.2 The lower distribution system shall be of the single point distributor type, constructed of PVC pipe and a fine slotted strainer to provide even flow distribution through the resin bed. The distribution system shall be embedded in a two layer subfill of washed inorganic material to support the resin bed. 4.3 MAIN OPERATING VALVE The main operating valve shall be of a top mount design constructed of thermoplastic resistant to attack by substances found in natural water supplies. Inlet and outlet connections to be 1.5" or 2 inch NPTE. The Cv (flow coefficient) of the main operating valve shall be equal to/greater than 32. A vacuum breaker and pressure regulating valve shall be integrated in the design of the main operating valve. The main operating valve will be of the motor driven, mechanically activated design with 5 positions to accomplish the regeneration steps of backwash, brine draw/rinse, fast rinse and brine refill in addition to the service position. The internal seals will be of a modular design for ease of replacement and service. The main operating valve will be fitted with a fixed orifice eductor to control brine draw/slow rinse. The main operating valve shall be designed by the same manufacturer as the water softener system and tested prior to shipment. 4.4 FLOW CONTROL The backwash flow controller shail be a pressure -compensating orifice capable of providing and maintaining proper backwash flows over the entire listed operating pressure range of the system. The backwash flow controller shall be easily serviced without special tools and design so that service to the flow controller can be performed without disassembly of the valve body or the sequencing controller and without disconnecting existing inlet and outlet piping connections. 4.5. CONTROLS A fully integrated programmable microprocessor driven electronic controller shall be provided to automatically cycle the main operating valve through the regeneration sequence. The electronic controller shall be designed and manufactured by the same manufacturer as the water treatment equipment. The controller shall be capable of initiating a regeneration by accepting an internal signal from the controller time keeping device; an external Hall -Effect flow sensor, a Culligan Aqua -Sensor®, an external device such as a remote start push-button or any combination of these methods. The controller shall sequence all steps of an automatic regeneration and automatically return the softener to a service or stand-by mode. The initiating time and/or volume setpoints shall automatically reset upon completion of the regeneration sequence. Page 2 of 5 The controller shall include a sealed keypad, capable of programming all controller functions, located on the face of the controller. The controller display shall be a multi -line OILED display capable of full text readouts of operating status and codes. The firmware shall be capable of being updated to the latest version. An audible. alarm beeper capable of emitting a tone of —70 dBA shall be available but capable of being disabled if so desired. The controller shall allow for a manual initiation of the automatic regeneration sequence by utilizing a regeneration selection from the controller menu. The controller shall operate on a low voltage electrical system, The system shall include a UUCUL listed transformer. The entire electronic control package and its associated inputs/outputs shall require not more than 24 VAC @ 50VA. The control shall be rated for web environments and certified to NEMA 3R. The controller shall utilize EEPROM to save pertinent programmed data and statistical functions. The controller must retain all functionality for power interruptions of less than 72 hours. A battery backup shall be installed and capable of maintaining the time of day for a minimum of 5 years. 4,5.1 System control options One or a combination of below control options shall be available Timeclock - An operator selected program of a time -initiated reconditioning for single units shall be available. The controller shall be capable of being entirely programmed in the field without additional interface devices. The operator shall be able to select reconditioning to occur after a specified number of hours or days or specific day of the week. The electronic controller shall indicate various data that includes number of reconditionings in the last 14 days, days since last reconditioning, total number of reconditionings for the life of the unit, current day of the week, time of day, and unit in reconditioning. Water Meter - An operator selected volume based reconditioning for single units shall be available. A flow sensor package shall be provided consisting with an appropriately sized installation fitting. The operator shall be able to select reconditioning to occur after a specified number gallons. The electronic controller shall indicate various data that includes number of reconditionings in the last 14 days, days since last reconditioning, total number of reconditionings for the life of the unit, time of day, and unit in reconditioning. Culligan Aqua Sensor- An operator selected program of immediate or delayed hardness initiated regeneration for single units shall be available. An Aqua-Sensoro control probe will be inserted into the resin bed and will sense the need for regeneration based on electrical impedance within the resin bed and will signal the circuit board to initiate regeneration after a continuous 6 minute increase in impedance ratio. The system will compensate for variations in water hardness and temperature and will require no field adjustments when operated within the normal temperature range of the softener, The controller shall be capable of being programmed in the field without additional interface devices. The controller shall indicate various data that includes number of regenerations in the last 14 days, days since the last regeneration, total number of regenerations for the life of the unit, last slow rinse time, time of day, and unit in regeneration. 4.5.2 In addition the following functions shall be provided as part of the system controller: The controller shall have the capability of providing communications with the following external devices: • Serial Communications (RS-232 & RS-485) • USB • Modbus RTU • Profibus Communications • BACnet Communications • Modem (cell modem or land -line modem) • dry Contact Alarm Relay • Wireless Remote (local RF wireless remote, 200 ft range) Regeneration sequence timers: The controller shall allow control customization of individual regeneration cycle times, each programmable from 1 - 99 minutes. The regeneration cycle and time of cycle remaining shall be displayed when in regeneration. Page 3 of 5 Lockout function: The controller shall include a lockout to prevent unauthorized personnel from altering program data. Regeneration override: The controller shall include a function to direct pre-programmed regeneration after a user determined period of time (hours or 24 hour intervals) without an input signal from another regeneration initiation device. Alarm status indicator: The controller shall monitor operation of internal functions. If a fault is identified, the need for operator intervention will be signaled visually within the controller display. Two Auxiliary Outputs: Two Auxiliary Outputs shall be integral to the controller circuit board. Each Output shall be capable of being programmed to provide power to a "Normally Open" or "Normally Closed" contact (user choice). These 24VAC outputs shall be used only for the purpose of energizing a relay coil. Flow rate indication: The controller shall be capable of indicating the flow rate of the treated water. Totalizer: The controller shall include a totalizer function and a display capacity to 99,999,999 units before resetting to zero. The totalizer value shall be displayed through the controller display during operation. The controller shall have the availability to be wall- or remote -mounted for greater accessibility. 4.5.3 Flow Sensor(s) Each softener will include a turbine -type Hall Effect flow sensor. The sensor shall be integral to the control valve. A cable shall be provided for direct connection to the system controller. The flow sensor package provided shall be functional within the flow range of 1.5 to 180.0 gpm. The flow sensor shall have an accuracy of +/- 2% over the full range. 4.5.4 Aqua -Sensor® Probe A patented Aqua -Sensors control probe will be inserted into the resin bed and will sense the need for regeneration based on an electrical imbalance within the resin bed and will signal the circuit board to initiate regeneration after a continuous 6 minute imbalance. The system will compensate for variations in water hardness and temperature and will require no field adjustments when operated within the normal temperature range of the softener. The controller shall be capable of being programmed in the field without additional interface devices. The Aqua -Sensor will also be capable of determining when the brine solution is rinsed from the resin bed during the Brine Draw /Slow Rinse cycle, triggering the control to move to Fast Rinse cycle. 4.6 EXCHANGE RESIN The ion exchange resin shall be virgin high capacity "standard mesh" of sulfonated polystyrene type stable over the entire pH range with good resistance to bead fracture from attrition or osmotic shock. Each cubic foot of resin will be capable of removing 30000.0 grains of hardness as calcium carbonate when regenerated with 15.0 pounds of salt. The resin shall be solid, of the proper particle size of 16x40 mesh, U.S. standard screen and will contain no agglomerates, shells, plates or other shapes that might interfere with the normal function of the water softener. The resin shall be manufactured to comply with the food additive regulation 21 CFR 173.25 as set forth by the USFDA. The system shall include 5 cubic feet of exchange resin per vessel 4.7 BRINE SYSTEM Provide a complete brine system consisting of a plastic tank, cover, salt platform, brine well, an automatic brine valve and all necessary fittings for operation with the water softening system, The system shall consist of a combined brine measuring and salt storage tank with salt platform. The brine tank will be equipped with a float operated non -corrosive field serviceable brine float valve for automatic control of brine withdrawal and fresh water refill. The brine valve will automatically open to admit brine to the resin tank during eduction and close automatically providing positive shut-off to prevent air from entering the system. The brine valve will also regulate the flow of Page 4 of 5 soft water into the brine tank during refill. The brine valve works with the timed fill feature of the main operating valve controls to admit the correct volume of fresh water to the brine tank in accordance with the refill time setting in the control program. The brine valve will include a float operated safety shut-off valve as a back up to the timed refill from the main operating valve control to prevent brine tank overflow. 4.8 ACCESSORIES 5.0 INSTRUCTIONS One (1) complete sets of installation, operating and maintenance manuals shall be provided. 6.0 FIELD SERVICE The services of a factory authorized service representative can be made available to supervise, inspect and provide operator training as required for initial start-up and system operation. Contact your local Culligan dealer for service rates and scheduling. 7.0 WARRANTY A single written warranty must be provided from the manufacturer of the water softener system covering workmanship and materials. 8.0 CTM MANUAL REFERENCE Installation Instructions : 01029401-A Smart Controller Communication: 01021612 Page 6 of 6 �������/\, New Design Technology for Commercial Softeners and Filters What Do Old ValveSpecs Cost You? OAMPM", twelfer waterpure and simple., 1 iiiiiii��05,21mulls%1 U#jq1;;i14i�1 All Brass Construction All Connections Are Threaded No Rating on Control Enclosure Limited Biackwash Flow Rate Multiple Motorized Piston Drives Rebuilding ReqUires Special Tools Requires External Flow Meter No Integrated Safety Features No Integrated Testing Ports Raw Exposure; of Moving Parts Pending Obsolescence C04an Consumer Setting a New Industry Benchmark Nr�rw Culligan Top Mount • Softener and Filter Capability • One Valve for 2" and 1.5" Connections • Valve Rated to "120 M • High Strength, Non -Brass Construction Materials with NSF 61/372 Certification • Superior Filter Backwash Rates Integrated Features for Safety and, Simplified Installation Easy Serviceability Access Points Wateirtilght�, NEMA 3R Enclosure UL, CS& and CE cerfifled CJR%a*v. balftr waler. drum and isimple.- IFW7� 3 Cullman Consumer CTIVI Delivers, Superior Flow Rates 140 120 100 80 60 LL 40 201 0 01 2 4 6 8 10 12 14 16 Pressure Drop (psi) 4 C01gan consumer Exclusive Cost -Saving Technology CJMPW-" bier wafet: pure and simpler Culligan Technologly Comments Benefits The CTM comes complete with More reliable and accurate than installing generic flow Integrated Flow Meters Cull igan-desig ned meter and meters. Vacuum Breakers vaCUUM breakers Integrated into the control. Avoids accidental vacuum collapse in FPR tanks. Brine Rectaint Returns reusable brine to the lank Reduces salt lusage by up to during the regeneration phase 25% Mitigates changes in water quality Improved Efficiency of Aqua Sensor/Smart Brine by signaling regeneration based on Systems Sensor Accessories resin bed conditions instead of on Cost Savings on Mter and time or flow volume alone Salt Yields higher system flow rates by dynamically bringing multiple tanks Saves on initial capital Progressive Flow on and off line. Ideal for applications where demand is investment and operating inconsistent or periodic and for expenses areas with space restrictions Remote Monitoring of Multiple Easier Preventative GBE Telemetry Capabilities Locations or Systems with LAN -line Maintenance ,and Mobile Connections '13 C1,1111fran COnWMer ejurvo-A bettgr wow. pure and simple." Culligan Confidently Backs the C�TMs with Full Unit Coverage for 3 years Triple the, Hi -Flo 3e iwarranty Covers Culligan accessories Coivers electronic ciontroller N,O,rA, Valve Bodyfor 5 years I - 3 y,rs on Hi Flo 3i3 brass body Media Tank, Brine Tank AND Br,ine Tanks Internalsfor 5 years 15 Culligan COMM" Limited Warranty You have Just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan Inter- national Company products, this product Is warranted to the original end -user, when Installed in accordance with Culligan specifications, against defects In material and workmanship from the date of original installation, as follows: For a period of THREE YEARS The entire metered model conditioner, Including Internal parts, The control valve Internal parts. The brine valve and Its component parts, Culligan -designed accessories limited to the flow motor, vacuum braker, pressure relief valve, plumbing adapter, GBE board, pilot valve and Aqua -Sensor Probe, For a period of FIVE YEARS The control valve body, excluding internal parts. The salt storage container Internal components. The fiberglass wound container(s), if so equipped*. The salt storage container(s), if so equipped. `The tank must be protected by a vacuum breaker device as described In the units operating manual. Damage to the tank caused by vacuum Is not covered by this warranty. The unit must be used In operating conditions that conform to Culil- gan's recommended design guidelines. This warranty will not apply if the unit has been modified, repaired or altered by someone not authorized by Culligan. If a part described above Is found defective within the specified period, you should notify your Independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. You pay only freight from our factory and local dealer charges. We are not responsible for damage caused by accident, fire, flood, freezing, Act of God, misuse, misapplication, neglect, oxidizing agents (such as chlorine, ozone, chloramines and other related components), alteration, Installation or operation contrary to our printed instructions, or by the use of accessories or components which do not meet Culligan specifications. Refer to the specifications section in the Installation and Operating manual for application parameters. Our product performance specifications are furnished with each water conditioning unit. TO THE EXTENT PERMITTED BY LAW, CULLIGAN DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE; TO THE EXTENT REQUIRED BY LAW, ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE ONE-YEAR PERIOD SPECIFIED ABOVE FOR THE ENTIRE CONDITIONER. As a manufacturer, we do not know the characteristics of your water supply or the purpose for which you are purchasing this product. The quality of water supplies may vary seasonally or over a period of time, and your water usage rate may vary as well. Water characteristics can also differ considerably If this product is moved to a new location. For these reasons, we assume no Ilabliity for the determination of the proper equipment necessary to meet your requirements, and we do not authorize others to assume such obligations for us. Further, we assume no liability and extend no warranties, express or Implied, for the use of this product with a nonpotable water source or a water source which does not meet the conditions for use described In the installation and operation manual(s) that accompany the equipment. OUR OBLIGATIONS UNDER THIS WARRANTY ARE LIMITED TO THE REPAIR OR REPLACEMENT OF THE FAILED PARTS OF THE WATER CONDITIONER, AND WE ASSUME NO LIABILITY WHATSOEVER FOR DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, SPECIAL, GENERAL, OR OTHER DAMAGES. Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Similarly, some states do not allow the exclusion of Incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Consult your telephone directory for your local independently operated Culligan dealer, or write Culligan International Company for warranty and service Information. Culligan International Company 9399 West Higgins Road, Suite 1100 Rosemont, Illinois 60018 Electrical Diagram Cord Grip /Enclosure Wall Loanut Card Grip Body Connectors inr Per cord conned 6rcuit board: its tr�raf®r\ Roure 21, 24 V Parer Conrredlio r Figure 22. Transformer and Sm.. rt Conttoller circuit board. Dry Salt Storage Fill the.Salt, Storage, Container Before filling the brine tank with. salt, add water until it is visible at the salt plate level. Then refer to Table 7 on pg9a 43 to f n.d.. the regeneration. capacity nosed on.the chosen salt dosage. The following terms will ire Helpful to know: • Max. Salt Fill, Ibs.- This value is. the: rnexlmourn number of pounds of salt.that can be out.into the brine tank,.This may be less.than the total capadly depending on whether there is wet or dry storage (see definitions beirw). No_ of Regens - This is the number of softener sylems regenerations that can be obtained from the maximum salt fn. • wet or Dry -.This column will note whether wet.or dry storage is required • pry Storage When enough self is added to the brine tank, so that the salt level Is. higher than the water level_ Men the proper amount of water ls. returried to the salt storage tank during brine refill (see Figure: `56)_ • wet Storage - Men the. salt level has to remain louver than the water level after refilt to prevent the displacement of the volume of water required for salt dosages of 12 Wit' or.greater. (see Figure 57). Figure K Dry storage. Figure 57. Wet storage. I have chosen the Brine System for your units that will give you dry storage. We, at Culligan, prefer to stay away from the hazards of wet storage. 1 tank will service 2 softeners, so you will require a total of 2 Brine Tanks