HomeMy WebLinkAboutOpening of Bids - Spec AF - One or More 2017 or Newer Tandem Axle Dump Truck - Truck Centers, Inc. - dba Hill Truck SalesCITY OF SOUTH BEND, INDIANA
SELLER'S BID FOR SALE OR LEASE OF MATERIALS
AND NON -COLLUSION AND NON! DEBARMENT AFFIDAVIT AND
NON-DISCRIMINATION COMMITMENT FOR SELLERS
BID NAME Spec AF — One (1) or More 2017 or Newer Tandem Axle Dump Truck
FOR BIDS, DUE December 12, 2017 at 9:30 a.m.
Bidder
Date: December 11, 2017 (Firm): Truck Centers, Inc, d/b/a Hil'II Truck Sales
Address: 1011 W. Sample St, South Bend, IN 46619
City/State/Zip: South Bend IN 46619 Telephone Number: (574) 2891-4065
Agent of Bidder (if Applicable): Rich Stopczynski, Sales Executive
When the prospective Contractor is unable to certify to any of the statements below, it shall attach (tit explanation to this Affidavit,
CONTRACTOR'S NON -COLLUSION AND NON -DEBARMENT AFFIDAVIT,
CERTIFICATION REGARDING INVESTMENT WITH IRAN, EMPLOYMENT
ELIGIBILITY VERIFICATION, NON-DISCRIMINATION COMMITMENT AND
CERTIFICATION OF USE OF UNITED STATES STEEL PRODUCTS OR FOUNDRY
PRODUCTS
(Must be completed for all quotes and bids. Please type or print)
STATE OF IN
) SS:
St. Joe COUNTY
The undersigned Contractor, being duly sworn upon his/her/its oath, affirms under the penalties of pctjury
that:
1, Contractor has not, nor has any other member, representative, or agent of the firm,
company, corporation or partnership represented by him, entered into any combination,
collusion or agreement with any person relative to the price to be bid by anyone at such
letting nor to prevent any person from bidding nor to induce anyone to refrain from
bidding, and that this bid is made without reference to any other bid and without any
agreement, understanding or combination with any other person in reference to such
bidding. Contractor further says that no, person or persons, firms, or corporation has, have
or will receive directly or indirectly, any rebate, fee, gift, commission or thing of value
on account of such sale; and
2. Contractor certifies by submission of this proposal that neither contractor nor any
of its principals are presently debarred, suspended, proposed for debarment, declared
ineligible, or voluntarily excluded from participation in this transaction by any Federal
department or agency; and
3. Contractor has not, nor has any successor to, nor an affiliate of, Conti -actor, engaged in
investment activities in Iran.
0
a. For purposes of this Certification, "Iran" means the government of Iran and any
agency or instrumentality of Iran, or as otherwise defined at Ind. Code § 5-22-16.5-5,
as amended from time -to -time.
b. As provided by Ind. Code § 5-22-16.5-8, as amended from time -to -time, a Contractor
is engaged in investment activities in Iran if either:
i. Contractor, its successor or its affiliate, provides goods or services of twenty
million dollars ($20,000,000) or more in value in the energy sector of Iran;
or
ii. Contractor, its successor or its affiliate, is a financial institution that extends
twenty million dollars ($20,000,000) or more in credit to another person for
forty-five (45) days or more, if that person will (i) use the credit to provides
goods and services in the energy sector in Iran; and (ii) at the time the
financial institution extends credit, is a person identified on list published by
the Indiana Department of Administration.
4. Contractor does not knowingly employ or contract with an unauthorized alien, nor
retain any employee or contract with a person that the Contractor subsequently learns is
an unauthorized alien. Contractor agrees that he/she/it shall enroll in and verify the work
eligibility status of all of Contractor's newly hired employees through the E-Verify
Program as defined by I.C. 22-5-1.7-3. Contractor's documentation of enrollment and
participation in the E-Verify Program is included and attached as part of this bid/quote;
and
5. Contractor shall require his/her/its subcontractors performing work under this
public contract to certify that the subcontractors do not knowingly employ or contract
with an unauthorized alien, nor retain any employee or contract with a person that the
subcontractor subsequently learns is an unauthorized alien, and that the subcontractor has
enrolled in and is participating in the E-Verify Program. The Contractor agrees to
maintain this certification throughout the term of the contract with the City of South
Bend, and understands that the City may terminate the contract for default if the
Contractor fails to cure a breach of this provision no later than thirty (30) days after being
notified by the City.
6. Persons, partnerships, corporations, associations, or joint venturers awarded a
contract by the City of South Bend through its agencies, boards, or commissions shall not
discriminate against any employee or applicant for employment in the performance of a
City contract with respect to hire, tenure, terms, conditions, or privileges of employment,
or any matter directly or indirectly related to employment because of race, sex, religion,
color, national origin, ancestry, age, gender expression, gender identity, sexual
orientation or disability that does not affect that person's ability to perform the work.
In awarding contracts for the purchase of work, labor, services, supplies, equipment,
materials, or any combination of the foregoing including, but not limited to, public works
contracts awarded under public bidding laws or other contracts in which public bids are
not required by law, the City, its agencies, boards, or commissions may consider the
Contractor's good faith efforts to obtain participation by those Contractors certified by
the State of Indiana as a Minority Business ("MBE") or as a Women's Business
Enterprise ("WBE") as a factor in determining the lowest, responsible, responsive
bidder.
In no event shall persons or entities seeking the award of a City contract be required to
award a subcontract to an MBE/WBE; however, it may not unlawfully discriminate
against said WBE/MBE. A finding of a discriminatory practice by the City's MBEIWBE
Utilization Board shall prohibit that person or entity from being awarded a City contract
for a period of one (1) year from the date of such determination, and such determination
may also be grounds for terminating the contact for which the discriminatory practice or
noncompliance pertains.
7. The undersigned contractor agrees that the following nondiscrimination
commitment shall be made a part of any contract which it may henceforth enter into with
the City of South Bend, Indiana or any of its agencies, boards or commissions.
Contractor agrees not to discriminate against or intimidate any employee or applicant for
employment in the performance of this contract with privileges of employment, or any
matter directly or indirectly related to employment, because of race, religion, color, sex,
gender expression, gender identity, sexual orientation, handicap, national origin or
ancestry. Breach of this provision may be regarded as material breach of contract.
I, the undersigned bidder or agent as contractor on a public works project, understand my
statutory obligations to the use of steel products or foundry products made in the United
States (I.C. 5-16-5-1). I hereby certify that I and all subcontractors employed by me for
this project will use steel products or foundry products made in the United States on this
project if awarded. I understand I have an affirmative duty to notify the City in my bid
that my proposal does not include the use of steel products or foundry products made in
the United States. I understand it is my sole obligation and responsibility to provide a
justification to the City, subject to review and approval, why the cost of United States
made steel or foundry products is unreasonable. Prior to award and upon submission of
bid which does not use steel products or foundry products made in the United States, the
City, through its director of public works, shall make a determination if the price of
United States made steel or foundry is unreasonable. I understand that violations
hereunder may result in forfeiture of contractual payments.
In
I hereby affirm under the penalties of perjury that the facts and information contained in the foregoing bid
for public works are true and correct.
Dated this 1 lth day of December, 20 17
Truck Centers Inc. d/b/a Hill Truck Sales
Contractor/Bidder (Firm)
Signature of nt • o Bidder or Its Agent
Rich Stopczynski, Sales Executive
Printed Name and Title
Subscribed and sworn to before me this day of Oe, 20f_U-
My Commission Expires �yIGt Ua U (, AAvU lu=
otary Public
=PublicALBERQA
Notary Seal County of Residence S ju:)Cy)
dianaCountyires May 9, 2024
11
(To be completed only by Contractors/Bidders clairtting to be a `local Indiana business " purstlant to I.C. 36-1-12-22)
INDIANA LOCAL BUSINESS PREFERENCE CLAIM
A "local Indiana business" refers to any of the following:
(1) A business whose principal place of business is located in an affected county.
(2) A business that pays a majority of its payroll (in dollar voluine) to residents of affected counties.
(3) A business that employs residents of affected counties as a majority of its employees.
(4) A business that makes significant capital investments in the affected counties as defined in rules adopted by the political
subdivision.
(5) A business that has a substantial positive economic impact on the affected counties as defined by criteria in rules adopted by
the political subdivision.
An "affected county" refers to St. Joseph Cozinty, Indiana, or the following counties located adjacent to St. Joseph County:
Elkhart County, Marshall County, Starke County and LaPorte County
There are the following price preferences for supplies purchased from a local Indiana business:
• 5% for a purchase expected by the purchasing agency to be less than $50, 000
• 3% for a purchase expected by the purchasing agency to beat least $50,000 but less than $100, 000.
• 1 % for a purchase expected by the purchasing agency to beat least $100, 000.
Date: December 11, 2017
Pursuant to I.C. 36-1-12-22, Truck Centers Inc. d/b/a Hill Truck Sales claims a local Indiana business
preference for Project _Tandem Axle Dump Truck (Project # __ pec AF ) located within the City
of South Bend, St. Joseph County, Indiana.
❑ The location of the principal place of business is �1011 W. Sample St, South Bend, IN 46619
(Address)
❑ St. Joseph County, Indiana
❑ The following county located adjacent to St. Joseph County, Indiana:
❑ The majority of the business's payroll for the 12 months prior to the date of this Bid is to residents of St.
Joseph County, Indiana or the adjacent county noted above.
❑ The majority of the business's employees for the 12 months prior to the date of this Bid are residents of
St. Joseph County, Indiana, or the adjacent county noted above.
If the business is deemed to be the apparent lowest, responsible, responsive bidder, then it shall provide
supporting documentation for the 12 month period prior to the date of the Bid of (i) the total payroll
amount paid to all employees of the business, and (ii) the total payroll amount paid to employees who are
residents of St. Joseph County and the adjacent county noted above.
WHEN SUPPLYING SUPPORTING PAYROLL RECORDS, BIDDER SHALL REDACTALL
SOCIAL SECURITYNUMBERS.
Dated this 1 lth day of December I l , 20 17
Truck Centers, Inc. d/b/a Hill Truck Sales
Cont c p Bidder (Firm)
ignature otto jqct •/Bidder or Its Agent
Rich Stonczvnski. Sales Executive
Printed Name and Title
Filled in by "fruck Centers lane:'.
BID NAME Spec AF — One (1) or More 2017 or Newer Tandem Axle Dump Truck
FOR BIDS DUE December 12,2017 at 9:30 a.m.
Pursuant to notices given, the undersigned offers bids) to the City of South Bend in accordance
with the following attachment(s) which specify the class or item number or description, quantity,
unit, unit price.
SPEC AF — ONE (1) OR MORE 2017 OR NEWER TANDEM AXLE DUMP TRUCK
It is the intent of these specifications to describe a vehicle or piece of equipment for the City of
South Bend. The unit shall be bid as a fully equipped complete unit as set out in the attached
specifications. No partial or split bids will be accepted. Unit to be bid with and without trade-in
if applicable. Vendor to complete bid proposal contained in this bid specification and attach to
the submitted bid.
These are minimum specifications. Any variation from the specifications must be spelled out on
a separate deviation list in order for the bid to be valid. Any items not listed on the deviation
sheet will be assumed to be part of the unit.
Proprietary products or specific manufacturers may be referenced herein. Such references are
only made to demonstrate minimum scope, quality, and style of the equipment desired.
Equipment that is bid pursuant to these specifications shall be of equal quality and size, or
greater', to those referenced, and are subject to approval by the South Bend Board of Public
Works.
Vendor shall provide all information requested in specifications to qualify for bid. If information
on brochure submitted does not completely cover specifications requested, it shall be typed and
attached to brochure.
If an alternate is included within these specifications, please be advised that, alternate items
placed in the specifications are to determine the best configuration of the item within a budgeted
amount and may be included in the award criteria, If the Board elects to award one or more (s),
the base bid price and the alternate bid price(s) will be totaled and compared for all bidders
offering the final configuration. Award will be made based on the lowest responsible/responsive
bid prices submitted for the base bid with selected (s), if applicable. Failure to submit a bid on
an alternate may result in the entire bid being non -responsive, depending on the final
configuration of the product.
Payment will be processed once the unit is inspected and accepted as to meeting the
specifications by the Division of Central Services. This will include all manuals and warranty
documentation.
9
Prepared for:
Board of Public Works
City of South Bend IN
County City Bldg.
South Bend, IN 46601
The following components deviate from listed specifications:
Prepared by:
Rich Stopczynski
Truck Centers, Inc.
1011 WEST SAMPLE STREET
SOUTH BEND, IN 46619
Phone:574-289-4065
stopczynski@truckcentersinc.com
Page 12 — Cooling: The radiator is designed with a steel reinforced conduit, through which the PTO shaft
passes and connects to the crankshaft This allows the engine to be placed lower in the chassis, thereby
dropping the hood height, and allowing for maximum visibility for the driver.
All other components meet or exceed minimum specifications.
Submitted by:
Rich Stopcz nski
Sales Executive
SB121217A - Tandem Diesel Dump bid Page 1 of 1
Bidder must state as accurately as possible an intended delivery date from the date of the
bid award. Due to the age of the City's existing fleet, it is imperative that the unit's be
delivered as quickly as possible. Stated delivery lead time may be included as an integral
part of our bid selection process. FOB Central Services. The unit and all related paperwork is
to be delivered to:
Central Services Division
1045 West Sample Street
South Bend, Indiana 46619
All Certificates of Origin/Title Work shall list the owner as:
The City of South Bend
1045 West Sample Street
South Bend, Indiana 46619
The Board will award the bid to the lowest responsible and responsive bidder. If the bid is not
awarded to the lowest bidder, the factors used to justify the awards will be stated in writing at the
request of any bidder.
The Board reserves the right to reject any and/or all bids or portions thereof and to waive any
irregularities or informalities.
SHALL BE
AS `>
DESCRIPTION
SPECIFIED
TYPE
(Circle One).:
Chassis:
Conventional cab chassis with a cab to axle dimension of 120".
YE / NO
Maximum of 199" wheel base, ground clearance minimum of 23"
for underbody mounting.
Front Axle:
20,000 lb. capacity
YES NO
Rear Axle:
46,000 lb. capacity, Rockwell SQHP or equal, geared for 65 mph
YES NO
top speed.
Front
20,000 lb. capacity, Heavy duty shock absorbers
YES NO
Suspension:
Rear
Hendrickson HN-402-52 or equal rubber suspension and
YES NO
Suspension:
transverse torque rods. Severe service suspension equaling
46,000 lbs.
10
TYPE
. DESCRIPTION
Tires Ten (10) hub piloted disc type wheels: 315/80R22.5. Front
& Wheels: Tire 20 ply radials Good Year G286 or equal. Rear tires
11R22.5 16 ply Good Year G338 or equal, tubeless
radials.
Engine: Turbo -charged, inline six cylinder electronic controlled
diesel engine. Minimum horse power 300, at 860 ft. lbs. of
torque, air to air after cooler required, emergency shutdown
system for low oil, high coolant temperature.
Provisions for front mounted crankshaft P.T.O. including flange for
adapting to front mounted pump, fuel/water separator. Air cleaner
to be dry type, two stage with provision to pull intake air from
under hood. Air cleaner to include restriction indicator. All hoses
to be silicone. Severe service material and hose clamps to be
constant tension type. 1000 watt engine block heater included.
Electronic Fan Clutch with manual over ride switch. Engine and
engine electronics warranty to be 5 year/150,000 miles.
YES NO
YES / NO
Transmission: Allison 3,500 RDS, five speed electronic automatic, furnished with OESNO
transmission temperature gauge, auxiliary oil filter and oil cooler.
Allison P-3 extended service coverage - 5 year unlimited miles shall
be included. Transynd transmission fluid included.
Fuel Tank: 60 gallon minimum capacity, slim line tank mounted
on left side with minimum ground clearance of 23". Tank to be
marked "Diesel Fuel".
Electrical: 160 amp alternator, 12 volt starter, two (2) maintenance
free batteries with total 1,900 CCA batteries. Lighting per D.O.T.
specifications. To be L.E.D. type lights. Cab to have
wiring and dash control for local installation of roof
mounted lights. Halogen lights included. All electrical
connections to be water proof. 6 position switch panel
with a dedicated power distribution center and circuit
breakers integral to trucks electrical system. Unit to have a 20 amp
battery feed and ground wire along with 15 amp ignition feed, all
three shall run to center of dash with approximately 2' of wire
coiled up.
11
YES NO
YES NO
Frame: 120,000 PSI frame with 15" minimum reinforced YES NO
integral frame extension for mounting of snow plow. C channel
reinforcement full length of frame including front frame extension.
Frame to have section models of 29 and RBM of 3,000,000
minimum.
Cooling: Radiator to be severe duty largest capacity available. Radiator must YES NO
be located to allow PTO shaft to pass under lower tank.
Wheel Seals: Oil type; front and rear. YES / NO
Steering: Dual hydraulic power. YES NO
Heater & Air Heavy duty factory installed air conditioning unit, heater and YES / NO
Conditioning: defroster, in accordance with manufacturer's specifications.
Cab: Two -man all steel severe -service cab. Interior cab height, measured DESNO
from floor to headliner must be a minimum of 54" to allow our
entire staff of drivers the proper work area to perform their duties as
expected. Bostrom air suspension high back driver's seat with arm
rest, passenger seat to be fixed. Tilt hood. Cab entrance assist
handles on each side of cab, 16" x 7" west coast and convex mirrors
heated and remotely operated with breakaway mirror brackets,
tinted windshield, intermittent windshield wipers and washer, dual
sun visors, seat belts for both seats, tilt and telescopic steering
column, and heavy duty door hinges. Electric locks and windows.
AM/FM CD player.
Cab to include hour meter, needle calibrated oil temperature gauge
for transmission, water temperature, engine oil, volt meter, air
pressure, and fuel gauges included. In addition, dual air horns with
snow shields, interior dome light, and hand throttle. Cab to include
cab mounted strobe light hooked into the Strobe system.
Exhaust: Vertical, must not interfere with CA dimension or YES NO
mounting of underbody. Vertical tail pipe guard and elbow
included.
12
:.SHALL
BE.
AS
TYPE
DESCRIPTION......SPECIFIED
(Circle One)
Brakes:
Anti -lock brake system to include 13 cubic ft. compressor
YES I NO
and Wabco style air dryer with spin on descant cartridge air
dryer or equal, with heater. Dryer to be mounted with
clearance for underbody equipment. Front brakes 16.5" x 6" with
20" brake chamber, rear brakes 16.5"x 7" with 30"
brake chamber. Automatic slack adjusters, front and rear.
Rear axle chambers to be mounted with clearance for paver to
contact rear wheels. Dust shields on front and rear. Trailer air
brakes with glad hands plus 7 way round pin plug at rear of truck.
Truck shall also have electrical brake controller with Bargman T-
way flat pin plug. Brake pedal to be mounted on firewall.
Parts List:
Vendor shall supply a complete list of part numbers of all filters
YES NO
including hydraulic, belts, and hoses along with fluid types and
quantities.
Rust
Five year minimum, full repair warranty. Cab and chassis
YES NO
Proofing:
to have Ziebart rust proofing and Rhino lining for under
Dump bed.
Safety:
Truck and equipment to conform to all State and Federal
YES NO
Requirements, as well as O.S.H.A. and D.O.T. Back up
Alarm to be included.
Colors:
Sewer Department — White Cab, Dark Green Dump Bed Dupont
(YES / NO
#474110B PFGS7
Manuals:
Complete set for chassis, engine, electrical, transmission, all add on
YES NO
equipment. Can also be CD or DVD. Must include access to
factory website for trouble shooting and parts lookup. Must include
1 year subscription for factory cab/chassis troubleshooting software.
Training:
Vendor to include up to eight hours of training for trouble shooting
YES NO
and parts software and website for Central Services employees.
13
in [,)y VV AJOni,,,,s SMALL RE
AS
TYPE DESCRIPTION SPECIFIED
(Circle One)
Specifications for 14'Ryfflp Body
The intent of these specifications is to obtain a dumb body which meets the highest standards of the
industry with respect to quality and strength of materials, design and workmanship, to the finished
product. Bidder MUST be an authorized representative of the manufacturer and able to provide
complete warranty service.
uin�Mw"'
Heavy Duty Note: Body builder must have a pre build conference with the (", YES , NO
Dump Body: purchaser to go over layout and placement off all equipment
and two such sessions during equipment installation. No
equipment shall be installed without approved authorization
from purchaser.
BODY:
These specifications shall describe a heavy-duty dump body, Ice and
Snow control equipment to be used by the City of South Bend Water
Department to maintain the streets. The equipment will consist of
Dump Body, underbody scraper, and a load sense central hydraulics
system, cable controlled with electronically controlled spreader. All
construction shall meet or exceed industries standards. Welding
shall comply with current AWS procedures.
Alternate to these specifications shall be noted separately at the end
of the proposal.
NOTE: To insure a proper working body and one that will meet the
city's needs, all placements of bed, bitch, lights, etc, shall be
approved by the city before installation. Body shall be heavy duty
168" in length Inside width shall be 86".
Note: there shall not be more than a two inch radius between the
floor and side wall. The bodv shall be built to fit the Citv's
existing leaf boxes. It will be the bidder's responsibility to, make
sure body, will accommodate leaf box
Sides and tailgate constructed of 3/16" Hardox 450 steel. No
exceptions to type or grade. Floor constructed of 1/4" Hardox 450
steel one piece. No exceptions to type or grade. Tailgate shall be 48"
in height.,
Front shall be 3/16" Hardox 450 No exceptions to type or grade.
Formed steel long members shall be 14" thickness reinforced w /
gussets. Understructure shall be crossmemberless, Lower body rub
14
77W, d iri [,)y VV A,Jm'ies
rail shall be 5-1/2" wide 35 degree slope outward for dirt shedding.
Grip strut walk bar shall be installed on both sides. Sides shall have
vertical post box bracing. Top Rail shall be fully boxed Lower rub
rail shall be material shedding.
The body shall have a rear spreader apron 12" deep, Apron shall be
pin on type and shall be able to interchange with tailgate spreader.
There shall be (two per side) gussets to accept 2" x 8" side boards.
Cabshield shall be 24" full width and be constructed of 3/16 450
Hardox.
Rear Pillar shall have three (4) ovals cut -in by the body
manufacturer for light placement.
There shall be a fold down ladder located on the dump body
mounted on the driver side front corner. Location shall be confirmed
at time of installation with purchaser.
There shall be a step type insert on the front driver's side on the
inside of the body.
Paint Body shall be painted to match the South Bend Water Works
body color. Bidder shall check on final color with the Fleet
Manager as to proper paint code.
Final paint shall be a baked on automotive finish,
Miscellaneous: 'There shall be installed a body prop, body up light,
back up alarm.
Body shall have 2 shovel brackets installed on the front of the body.
Cab Shield: Cab protector shall be made from 8 gauge steel with 2" x 3" flat
steel reinforcement.
Y ( NO
I ES,
Tailgate: Tailgate shall be two formed panels will be single wall constructed YES �,)NO
with 1/4"" Hardox 450 and shall be double acting.
Tailgate chains shall be encased in chain mesh
Two sets of cast banjo plates and chains long enough to hold tailgate
in down position.
Rear Pillar shall have sloped top. Minimum I" flame cut offset
upper tailgate hinge. Minimum 1-1/2" upper tailgate pin.
All welds shall be 100% continuous. Minimum 1- 1/4" lower tailgate
pin incorporated in lower vertical tailgate brace
Minimum 3/8" diameter proof coil spreader chains. Complete
tailgate latching assembly reinforced with a 1/4" backing plate for
added strength. Upper and lower banjo eyes in each rear corner post.
Air operated tailgate latch mechanism.
All tailgate pivots are grease zerk lubricated.
Telescopic The hoist shall be of telescopic design and have a Trunion (YE NO
Hoist: mounting.
The hoist shall be double acting
The hoist shall be designed to operate up to 2,500 PSI, and shall be
self -bleeding.
15
The hoist shall have a V4" wall construction with bronze glands and
pistons to assure a smooth and durable bearing surface.
The glands shall each be a continuous cast bearing, SAE,660 bronze
with a tensile strength of 44,000 PSI.
The cylinder bead and piston shall be of a "ductile" continuously
cast iron, with a tensile strength of 60,000 PSI.
Each cylinder shall be internally seated.
The inside seals shall be of a u-cup design made of nitrate packing.
The cylinder shall have a Melonized/Q.P. running surface.
The Melonized surfaces shall have a predominance of single—phase
epsilon nitride. The nitride shall cover the entire cylinder surface.
This shall give the cylinder superior wear and corrosion resistance
and also shall have superior wear and fatigue properties.
The cylinder rod shall be el 045/cl 050 steel with a tensile strength
of 80,000 to 1000,000 pounds.
The cylinder tubing shall be D.O.M. tubing, drawn over a mandrel,
and shall have
Tensile strength of 70,000 pounds. The tube shall have a surface
harness of 80 Rockwell "B".
The cylinder shall dismantle easily and overlap between stages for
greater stability, The trunion collar shall be oscillation
Each rod or pin eye shall have a grease zerk, The hoist shall have a
two year warranty.
Hoist shall incorporate a body prop, and body up light.
Controls: There shall be two variable speed hydraulic controls mounted in the
cab so that it may be operated as a spreader. One control will
govern the conveyor speed; the other will control the spinner speed,.
There shall also be a control valve located at the rear of the truck to
allow an operator to start and stop the conveyor from the rear of the
truck.
Colors: Water Works - White Cab, Blue Dump Bed C64801,C-14 Alt. #1 ' Sewer Department — White Cab, Turquoise Tropic Green Dump
Bed 97561A.
Ladder:
D-Rings:
Tarp Rods:
Tarp:
A ladder will be provided for access to dump body.
Bed shall have 3 D-Rings on each side of bed to mount leaf box,
Tarp rods are to be provided on the body.
"YES
NO
YES NO
YE NO
rm
E NO
Shall have a pull type tarp equal to what the City is currently using. . . .YE ...... ........ . .... NO
LEO
on by \IV
Mounting of Dump Body
Shall have a minimum of three (3) brackets (each side) - 2"x 4" flat iron minimum, at least one at rear,
one in center, one at front. Shall be welded at rear and bolted with three (3) 5/8" bolts per bracket
(minimum). Hoist cylinder shall be hooked to central hydraulics with 3/4" high pressure hose (two
wire minimum). Floor of body to be approximately 54" off ground +/- 2". All welding to be done at
factory on box. Other welding to be certified. Two rear hooks shall be supplied and bolted to rear of
fi-ame. LED lights.
Electrical: All lighting shall be LED, YES NO
The wiring junction box is to be located on the right side of
the body a minimum of 58" off the floor. The electrical
box is to be completely sealed and waterproof All wiring
to be continuous (without splices) and run inside of a
waterproof harness. All connections are to be made inside
waterproof junction boxes or within the structure of the
body, Warning lights, strobes, and plow lights each to be
run off OEM switches, Also included will be a pair of
Track Lite LED Model #80880 or equal plow lights mounted to
stainless steel brackets on hood. Plow lights to LED and integral to
OEM headlights, Sealed lighting system shall be installed
consisting of four (4) nylon tail/brake lights, two (2) on each side,
and two (2) Whelen amber nylon alternating strobe flashing lights,
one (1) on each side, mounted at top and two backup lights, one per
side. The sealed lighting system shall be boxed into the rear corner
posts, not to exceed a total box width of 99". All light wiring shall
be in sealed tubing. All lights shall be standard 3 pin plug in style.
There shall be a set of LED amber strobe lights mounted in weather
protected boxes mounted under the cab shield facing forward.
There shall be a second set of LED strobes mounted under the cab
shield facing on both sides of body. Lights shall be installed in
approved manor by the City. There shall also be an underbody
plow light that will direct light on the underbody plow and a
spreader light positioned at the left rear lower corner of the bed.
Rear Pintle Wallace Forge 2044101, 50,000 lb or equal, mounted rear of truck, YES NO
Hitch: center of hitch 25 1/2 " from. ground and center of track. 11 .
Capacity: 6,000 Ibs. maximum vertical load qYES )NO
50,000 tbs. maximum gross trailer load
Drawbar eye dimensions: 2" to 3" ID 1 1/4" to 1 5/8" diameter
section.
Note: Vendor will check with Central Services on exact location of hitch YE I NO
and exact location of all rear mounted lights.
WA
F: A B d e d Dui VV A J () n e
Minimum Specifications For A Close Center Load
Hydraulic The hydraulic pump shall be US manufactured axial piston pressure YES NO
-S
Pump: and flow compensated load sensing type. The pump shall be cast
iron construction and rated to 4,00 cubic inches per revolution at
maximum stroke, The pump shall have a two inch suction line.
The pump shall be rated for up to 3000 rpm and pressure. The
pump shall have a 1 1/4" keyed drive shaft and SAE type C
mounting flange. The pump, shall be model PAVC 65 Parker load
sensing pump or equal. A I " steel ball valve shall be at the outlet of
the pump.
Hydraulic Pump The hydraulic pump will be a cast iron, variable
displacement piston pump with load sensing control. Pump to feature
internal bleed down compensator and separate adjustments for stand by
and main pressure. Pump shall be Sauer Danfoss FRL series pump or prior
approved equal. Pump capacity 90CC.
Pump shall have a shutdown circuit. Circuit shall be energized by
a tank mounted float to shut off pump flow in the event of a low
oil condition,
Shutdown system shall have a cab mounted system override switch.
Mounting: The hydraulic pump shall be mounted with shaft centerline parallel
( YES) NO
to the crankshaft centerline and at a level to create not more than a
three degree angle on the drive line. The pump mounting shall be
incorporated with a bracket fabricated to mount in the extended
rails from the pump.
Driveline: The hydraulic pump shall be driven directly off the engine
(".'YES
crankshaft via a splined driveline to, allow for movement. The
��NO
driveline shall include grease fittings on both u-joints. Spicer.
model 1310 series or equal.
Reservoir: The hydraulic reservoir shall be of the slim line type and
Y E NO
shall be mounted between the chassis and the dump body,
. .... .
The mounting of the reservoir shall not extend the cab to
axle dimension of the chassis,
The hydraulic reservoir shall be 40-gallon capacity and be
equipped with the following: Basket type filler breather
cap, magnetic drain plug, 2" NPT suction with I 00-mesh
screen type filter, separate return port for control drain line,
sight temperature gauge externally mounted, internal
baffling, heavy duty 1 1/4" ball type shut off valve shall be
mounted on the suction side.
18
Hydraulic Lines All hydraulic lines, pipes, hoses, and fittings shall be of
& Plumbing: sufficient capacity to accommodate the volume of oil
without undue heating or turbulence in the system. A 2"
suction line with a minimum SAE rating of 100-R4 must be
used between the reservoir and the inlet of the pump. This
suction hose shall be secured on both ends via heavy duty
banding straps, radiator hose clamps -unacceptable. All of
the pressure hoses, including the signal sensing line to the
pump must have swivel fittings on BOTH ends and have a
minimum SAE rating of 100-R2. Return lines and the case
drain line must have a minimum SAE rating of 100-RI.
All fittings shall be JIC. Push on clamp fittings are not
acceptable.
Hydraulic lines shall be routed to minimize interference
with equipment and chassis components requiring periodic
servicing. Appropriate support brackets, grommets, and tie
wraps shall be provided to protect lines from abrasion,
cutting and impact damage. Hoses shall not be installed
near manifold or exhaust pipes so as to be affected by
extreme heat. There shall be no pipe fitting used with any
high pressure lines. Any and all hydraulic quick disconnect
couplings used for spreader system and snow plow
reversing system shall be of the bulkhead mounted style
and be rigidly attached without the use of any hose clamp
arrangements (loose hose ends are NOT acceptable), Couplers to
be mounted to side of dump bed so they do not get covered with
material or broken. Dust cap for male ends and dust plug for
female ends must be attached to couplers. Maximum distance
allowed between support clamps on all hydraulic hoses shall be
approximately 24".
Electronic The spreader control will utilize PWM technology to
Manual control the variable feed and spread widths. The feed rate
Spreader knob will accommodate 9 different settings while the
Control: spread width knob will also accommodate 9 settings. The
control head will have a power switch with an indicator
lamp to provide status on the operation of the controller. Unit to be
mounted for safe use by driver.
Controller shall be Storm Guard Freedorn 2 controller.
Spreader control shall have ability to be touch screen with usb data
download.
TEP wiring harness.
Screw on cap and plug set for motor sensor connection.
Detailed operators manual,
19
YES )NO
YES')NO
F i V k,) d au a I-)y W A J ir,,), �u
Calibration manual.
Wiring diagrams.
Spreader Control Harness System:
Spreader control and the hydraulic valve shall be connected via TIDE
harness system,
System will include a diagnostic board with direct reading LED
circuit indication.
Wiring system will exclude any infusion of direct application of
1000 PSI pressure wash spray.
Connectors shall withstand 500 hours of 35C salt spray,
The controller will also offer a combination "blast" -
"unload" switch, This switch will allow the controller to
produce a Blast function with programmable duration and a
maintained unloads position for unloading the spreader or
offering continuous operation during cleaning. The
controller will allow the attachnient of speed pickup to start
and stop the material spreading with vehicle motion.
Wiring harness for the spreader control shall be full factory
assembled with waterproof ends and covered in expanded
nylon abrasion sleeve. A separate fuse shall be included
into, the controller to protect it in the event of a short circuit
deploying the inline fuse included in the installation.
Controller shall be mounted in the cab with all hydraulic
lines and valves outside: of the operator's compartment.
All wiring that leaves the cab, such as valve supply and
speed pickup, shall be secured with rubber covered steel
clamps and include a watertight strain relief at the cab exit.
Control Valve: The control valve shall be US manufactured, The valve is to be YES NO
Greisen Model V40/V20 or equal load sensing stackable spool type
with 0-ring ports mounted between the frame rails outside the
vehicle cab. Hoist section and tool circuitry section to be V40 and
all other sections to be V20. Valve sections to be arranged as
follows:
Hydraulic Valve: The hydraulic valve will be a cast iron, sectional type
spool valve. Valve will feature individual section and flow compensation for
each section. The valve will be rated for a nominal flow of 30 gpm. The load
sensing shuttle network will be accessible without valve disassembly.
Sections will be provided for following:
1. Hoist, double acting cylinder with down side work, port relief set
as 500 psi.
2. Mid-inlet/transition section.
3. Underbody plow lift, double acting cylinder with down side
20
work port relief set at 500 psi.
4. Underbody plow angle, double acting cylinder with
auxiliary cross port relief valve to protect cylinder.
5. Spinner attaclu-nent, dual compensated control.
6. Plow lift, double acting cylinder with down side work port relief
set at 500 psi.
7. Valve Controls and Enclosure: The valve assembly shall be
mounted in weather -tight enclosure. The valve enclosure shall be
fabricated of 12-gauge steel, Enclosure shall be designed to not
allow humidity to be trapped inside, Valve to be mounted with all
ports coming out of the bottom and holes allowing for hose adaptor
fitting. Enclosure will allow for bulkhead style cable to enter the
fi,ont, Valve will be boxed in with cover and not the base. The
cover shall be held to the enclosure by four heavy rubber latches.
All plumbing shall be external, directly out the bottom of the valve
enclosure.
Specifications for Mounting Underbody Blade Assemblies
It is the intent of these specifications to describe an adjustable YES ANC
angled underbody scraper assembly.
Note: In bidding this item, please include any cab controls or
hydraulic modifications necessary.
Each truck shall be equipped with a root model F-89 or equal
underbody truck scraper.
Hanger board shall be not less than 10" x 30 lbs, Structural channel
reinforced by 1/2" x 8" plate and by 4" S & C 13.8# Channel the
entire length of hinge line.
Hinge shaft shall be not less than 2" OD high carbon steel.
Moldboard shall be 10' long, I " x 20 " heat treated high carbon
steel, offset for USS punched blades. Circles shall be constructed
of heavy duty I " thick solid steel. One (1) piece design (no casting)
with four (4) independent heavy duty mounting legs of 4" S & C
channel 13.8# per foot. Moldboard shall be cushioned by two (2)
heavy duty cushion spring shock absorber assemblies.
Scrapers shall have dual cylinders. Power reverse with two (2) 4"
double acting cylinders with chrome plated rods. Cylinder rods
clevis bosses to be 2" OD carbon steel, solid welded to the top and
bottom of the hanger board. Scraping angle should not be less than
45 degrees adjustable as desired. All moving parts shall be zerk
equipped. Power shall be provided from central hydraulic system,
W
RU 4'� by W A
Moldboard to be actuated by two (2) 4" double acting cylinders
mounted horizontally on the scraper by 3/4" thick reinforced steel
trunnion brackets. Trunnion bearings shall be 2" OD x 1 1/4"
carbon steel.
Blade down pressure shall be adjustable and with no less than 1,500
lbs. maximum to be set at 600 PSI.
All fittings to be JIC. Push on fittings shall not be accepted.
Underbody scrapers shall be furnished with 8" x 3/4 standard
carbon flame hardened blades.
Moldboard shall have replaceable blade and end bits.
Power reverse shall be cab controlled.
Underbody grease zerts shall be centrally located.
Specifications for Snow Plow Quick Hitch Large
General. Snow plow quick hitch shall be heavy duty type to be used for street
and/or highway snow plowing by heavy duty trucks. Hitch shall be
designed to permit adequate lift and full radius swing of hydraulic
controlled power reversing snow plows.
Type: Snow plow hitch shall be an automatic snap coupling type, 34" wide,
equipped with 3" diameter by 10" stroke hydraulic lift cylinder.
Automatic locking shall be accomplished by dual cam actuated
spring loaded locking lugs, A lever shall be provided for retraction
of looking lugs. Looking lugs shall be I - 7/8" minimum diameter with roller
bearings to aid in lifting and lowering plow.
Construction; Truck Half. The truck half of the automatic snap coupling hitch shall
be 34" wide, 42" high and shall be fabricated from 3/8" thick structural
steel, adequately cross membered and securely mounted on the trucks
extended ftont frame. Bottom support members shall be securely
attached to the main frame of truck chassis at approximately the center
of the front axle. Anti -thrust plating shall be incorporated to prevent
transverse movement of hitch and rearward thrust against triangulating
bottom support members. Stabilizer bars shall be connected between
top portion of the hitch and main frame of the truck.All fasteners shall
be of the high tensile type. A lift arm and base support for the hydraulic
cylinder shall be included. Lift arm to be one solid piece of 3/4" material
with one piece 2 1/2" x 3 1/4" long cold rolled round welded on the lift arias
22
1: ii � �ed o r� by VV A , l on es,
at lift point. Top brace to be 3/8" x 2" x 2". Bottom brace to be 2" x 3" x 3".
Rear vertical brace to be 3/8" x 2 1/2" x 2 1/2"',
goo '4
Color: Water Works - White Cab, Blue Dump Bed C6480KH Alt. #1. YES
Sewer Department— White Cab, Turquoise Tropic Green Dump
Bed 97561 A.
Quantity: One (1) or more YES/NO
Trade -In: Unit SN464, 2000 Freightliner Dump 'Truck,
VIN#IFVXJFBBIYHO10099
Alternate 4 1: Quick Hitch for Front Plow
Truck frarne will be extended forward of grill. Bidder will furnish
minimum 2"x 4"' x 8" x 48"' long angle across front bumper..
Bottom braces shall be installed from hitch to frame with 3 1/4 bolts,
grade 8. Material I " x 4" flat iron minimum. Top braces 2"x 4"
flat iron minimum and run to frame. Hose to hook up hitch and
cylinder shall be 3/8" and furnished by bidder. Hooked to
hydraulics part with 1,000 lbs, PSI port relief minimum. Bumper
angle is to be mounted to fi-ame with four (4) pieces of 4" x 8"
minimum angle to frame. Hood to have cable stop before resting on
plow hitch. Plow lights to be included.
Truck frame will be extended forward of grill. Bidder will furnish
minimum 2"x 4" x 8" x 48" long angle across front bumper.
Bottom braces shall be installed from hitch to frame with 3 3/4"
bolts, grade 8. Material I " x 4" flat iron minimum. Top braces 2"x
4" flat iron minimum and run to fi-ame. Hose to hook up hitch and
cylinder shall be 3/8" and furnished by bidder. Hooked to
hydraulics part with 1,00�0 lbs. PSI port relief minimum. Bumper
angle is to be mounted to frame with four (4) pieces of 4" x 8"
minimum angle to frame, Hood to have cable stop before resting
on plow hitch. Plow lights to be included.
Alternates #2: Front Snow Plow
s YES/11C
Moldboard length ill
Height 4311
Width of cut ill
28 deg. 011
35 deg. 91011
42 deg 812"
23
F1He(,'J udi [-,,ay W A,Jo raes
Moldboard deflector - Built-in
Left hand discharge ear
Right hand discharge ear
Cutting edge - 2"x 6 with US Highway Blade Punching
Lift 1011
Trip Spring 2 Canon Style
Rebound Standard
Hinge Points, & Size 4-1
Outside Hinge Spread 8511
Size Semicircle Angle 3 1/2" x 3 1/2" x 2
Moldboard Bottom Angle 411 x 4" x 3/4"
Top Moldboard Stiffener 3" x 3" x 3/8"
Hitch Complete - Hustin Style 34" Quick Hitch
Snow Wheels Brand Shoes - 2 with Full Height Adjustment
Curb Guards - Left and Right Hand Replaceable
Alternate #3: CNG Fuel System-
320 horsepower, with 1,000 ft. lbs, torque minimum Cummins
Westport ISL G320 natural gas engine. Emergency shutdown
system for low oil pressure, high water temperature. Air filter shall
be replaceable paper type with a restriction gauge. Oil filter to be a
combination full flow/bypass type. Fuel system to include a low
pressure coalescing fuel filter. 1,500 watt block heater, with
thermostat, to be included. Engine warranty to be a minimum of 5
years/200,000 miles/1 0,000 hours. Engine troubleshooting
manuals/software to be included. Fuel tank capacity 75 DGE.
Alternate #4: Stainless, Steel Monroe tailgate spreader Model #MS966
Price Guarantee: The successful bidder shall guarantee the bid price for a minimum
of 12 months ftom the bid award date to the City of South Bend,
The City reserves the right to purchase up to three (3) additional
units at this price.
Warranty: Chassis,: 12 months/12,000 miles complete. Body, hoist,
underbody - 12 months from date of delivery. Engine and
transmission as specified. The unit shall be awarded as a complete
dump truck with snow equipment, The successful bidder shall be
responsible for all warranty repairs. The successffil bidder shall
provide written certification of all extended warranties at the time
of delivery.
It is, the objective of Equipment Services to keep this
equipment available for service on a 24 hour basis,
especially during the winter season. Therefore, repairs
that may require lengthy travel time and distance may
24
YES/0
0
YE
NO
F Med iui by V/ A Joi"w
affect this bid. It will be at the discretion of Equipment
Services as to the location at which the warranty work will
be performed.
A. Your service man at our shop.
E. Your service man at your shop.
Note: If the work is to be performed at your shop and your
shop is located outside of the City limits,, you will be
responsible for pick-up, and delivery of the unit, within eight (8)
hours of notification or you will be assessed $ 100.00.
Pre -Construction: Vendor will have pre construction meeting at Central Services.
Nk,
BID NAME Spec AF — One (1) or More 2017 or Newer Tandem Axle Dump Truck
FOR IBiDS DUE December 12, 2017 at 9,30 a.m..
Description
Year/Make/Mandell
Unit Price
Complete Unit Sid
2019 Freightliner Model 114SD with equipment
by W.A. Janes Truck Bodies & Equipment
li
$ 151,167.010
Year
Make/Model — "Trade In
Unit Price
2000
Unit SN464, Freightliner Dump Truck,
VIN# l FVXJ B B I YHG10099,
(5,000.00)
Alternate#
Description
Cost
Total
I
Quick Hitch for Font Plow
$ 4,398.00
$ 4,398.00
2
Front Snow Plow
$ 9,478.00
$ 9,478,00
3
LNG Fuel System
$ 43,220.00
$ 43,220.00
4
Stainless Steel Monroe Tailgate
reader: Model #MS966
$ 3,982.00
$ 3,982.00
Estimated number of days for delivery from award 180-210 days
date,
Bidder (Firm):
Ciity/State/Zips
Telephone Number:
Truck Centers, Inc. d/b/a Hill Truck Sales
1011 W. Sample St.
South Bend, IN 46619
574-289-4065 Fax Number: 574-289-1497
By
Signature). µ~
(Printed' Name)
26
(Title)
BOARD OF PUBLIC WORKS
Gary A. Gilot, President
Suzanna M. Fritzberg, Member
James A. Mueller, Member
Elizabeth A. Maradik, Member
Therese J. Dorau, Member
Attest: Linda M. Martin, Clerk
27
Document A31 OTM-2010
f 04 V I 01r, re 1
CONTRACTOR:
(Nance, legal stakes and address)
SURETY:
This document has important
(Marne, legal slaws and priwipal place ofbushwss)
legal consequences.
TRUCK CENTERS, INC.,
Travelers Casualty And Surety Company Of
Consultation with an
2280 Formosa Road
America
attorney is encouraged with
Troy, IL 62294
One Tower Square
respect to its completion or
Hartford, CT 06183
modification.
OWNER:
Mail Notices To:
Any singular reference to
Contractor, Surety, Owner,
(Nance, legal status and address)
Travelers
Attn: Surety Claim Dept.
or other party shall be
C Of South Bend/Board Of Public Works
City
One Tower Square 2S1 A
considered plural where
County City Building Room 1316
Hartford, CT 06183
applicable.
227 W� Jefferson Street
South Bend, IN 46601
BOND AMOUNT- Ten Percent of the Amount Bid .................. dollars ($ 10% of Amount Bid)
PROJECT: 2017 or Newer Tandem Axle, Dump Truck
(Maine, location or address, and Project number, if airy)
The Contractor and Surety are bound to the Owner in the amount set forth above, for the payment of which the Contractor and
Surety bind themselves, their heirs, executors, administrators, successors and assigns, jointly and severally,, as provided herein. The
conditions of this Bond are such that if the Owner accepts the bid of the Contractor within the time specified in the bid documents, or
within such time period as may be agreed to by the Owner and Contractor, and the Contractor either (1) enters into a contract with the
Owner in accordance with the terms of such bid, and gives such bond or bonds as may be specified in the bidding or Contract
Documents, with a surety admitted in the jurisdiction of the Project and otherwise acceptable to the Owner, for the faithful
performance of such Contract and for the prompt payment of labor and material furnished in the prosecution thereof, or (2) pays to the
Owner the difference, not to exceed the amount of this Bond, between the amount specified in said bid and such larger arnount for
which the Owner may in good faith contract with another party to perform the work covered by said bid, then this obligation shall be null
and void, otherwise to remain in full force and effect. The Surety hereby waives any notice of an agreement between the Owner and
Contractor to extend the time in which the Owner may accept the bid. Waiver of notice by the Surety shall not apply to any extension
exceeding sixty (60) days in the aggregate beyond the time for acceptance of bids specified in the bid documents, and the Owner and
Contractor shall obtain the Surety's consent for an extension beyond sixty (60) days.
If this Bond is issued in connection with a subcontractor's bid to a Contractor, the term Contractor in this Bond shall be deemed
to be Subcontractor and the term Owner shall be deemed to be Contractor.
When this Bond has been furnished to comply with a statutory or other legal requirement in the location of the Project, any provision
in this Bond conflicting with said statutory or legal requirement shall be deemed deleted berefrom and provisions conforming to such
statutory or other legal requirement shall be deemed incorporated herein. When so furnished, the intent is that this Bond shall be
construed as a statutory bond and not as a common law bond.
Signed and sealed this 12th day of December, 2017.
(witnelss)
d-
Witness) Donna Robson, Wince
TRUCK CENTERS, INC.
(Principal) (Seal)
lr-' r
av-c N
Travelers Casualtv AV Company Of America
(Su
lt Ar) (Seat)
(Title) Andrew P. Thorne, Attorney -In -Fact
Init. AIA Document A3 10TM— 2010, Copyright 01963, 1970 and 2010 by The American Institute of Architects. All rights reserved. WARNING: This AIA DOCU ni ent is
protected by U.S. Copyright Law and International Treaties, Llnauthmized reproduction or distribution of this AIA Document. or any portion of it, may result in
severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. Purchasers are permitted to reproduce Len (10) copies of this
document when completed. To report copyright violations of AIA Contract Documents, e-mail The Annerican Institute of Architects' legal counsel, copyrighLOala.org, 061110
State of Missouri
County of St. Louis
On 12/12/2017, before me, a Notary Public in and for said County and State, residing therein, duly
commissioned and sworn, personally appeared Andrew P. Thome known to me to be Attorney -in -Fact
of
TAMITME.
the corporation described in and that executed the within and foregoing instrument, and known to me to
be the person who executed the said instrument in behalf of said corporation, and he duly acknowledged
to me that such corporation executed the same.
IN WITNESS WHEREOF, I have hereunto set my hand and affixed my official seal, the day and year
stated in this certificate above.
Donna Robson, Notary Public
DONNA ROBSON
Notary PuNic — Notary Seal
st,ite of missouri, St. Chm-les COLOW
commission it 171,67942
My Commission Expires: My Commission Expires June 21, 2021
TRAVELERS i
POWER OF ATTORNEY
Travelers Casualty and Surety Company of America
Travelers Casualty and Surety Company
St. Paul Fire and Marine Insurance Company
Attorney -In -Fact No, 231637
KNOW ALL MEN BY THESE PRESENTS: That Travelers Casualty and Surety Company of America, Travelers Casualty and Surety Company, and St.
Paul Fire and Marine Insurance Company are corporations duly organized under the laws of the State of Connecticut (herein collectively called the
"Companies"), and that the Companies do hereby make, constitute and appoint Andrew P Thorne, of the City of Chesterfield, State of Missouri, their true
and lawful Attorney -in -Fact to sign, execute, seal and acknowledge any and all bonds, recognizances, conditional undertakings and other writings
obligatory in the nature thereof on behalf of the Companies in their business of guaranteeing the fidelity of persons, guaranteeing the performance of
contracts and executing or guaranteeing bonds and undertakings required or permitted in any actions or proceedings allowed by law.
IN WITNESS WHEREOF, the Companies have caused this instrument to be signed and their corporate seals to be hereto affixed, this 3rd day of
February, 2017.
Travelers Casualty and Surety Company of America
Travelers Casualty and Surety Company
St. Paul Fire and Marine Insurance Company
State of Connecticut
City of Hartford ss.
Robert L. Raney, Senior Vice President
On this the 3rd day of February, 2017, before me personally appeared Robert L. Raney, who acknowledged himself to be the Senior Vice President
of Travelers Casualty and Surety Company of America, Travelers Casualty and Surety Company, and St, Paul Fire and Marine Insurance Company, and
that he, as such, being authorized so to do, executed the foregoing instrument for the purposes therein contained by signing on behalf of the corporations
by himself as a duly authorized officer.
In Witness Whereof, I hereunto set my hand and official seal.
My Commission expires the 30th day of June, 2021
0�„TE7
* AUEUO * Mar'ie C. Tetreault, Notary Public
This Power of Attorney is granted under and by the authority of the following resolutions adopted by the Boards of Directors of Travelers Casualty and
Surety Company of America, Travelers Casualty and Surety Company, and St. Paul Fire and Marine Insurance Company, which resolutions are now in full
force and effect, reading as follows:
RESOLVED, that the Chairman, the President, any Vice Chairman, any Executive Vice President, any Senior Vice President, any Vice President, any Second
Vice President, the Treasurer, any Assistant Treasurer, the Corporate Secretary or any Assistant Secretary may appoint Attorneys -in -Fact and Agents to
act for and on behalf of the Company and may give such appointee such authority as his or her certificate of authority may prescribe to sign with the
Company's name and seal with the Company's seal bonds, recognizances, contracts of indemnity, and other writings obligatory in the nature of a bond,
recognizance, or conditional undertaking, and any of said officers or the Board of Directors at any time may remove any such appointee and revoke the
power given him or her; and it is
FURTHER RESOLVED, that the Chairman, the President, any Vice Chairman, any Executive Vice President, any Senior Vice President or any Vice President
may delegate all or any part of the foregoing authority to one or more officers or employees of this Company, provided that each such delegation is in
writing and a copy thereof is filed in the office of the Secretary; and it is
FURTHER RESOLVED, that any bond, recognizance, contract of indemnity, or writing obligatory in the nature of a bond, recognizance, or conditional
undertaking shall be valid and binding upon the Company when (a) signed by the President, any Vice Chairman, any Executive Vice President, any Senior
Vice President or any Vice President, any Second Vice President, the Treasurer, any Assistant Treasurer, the Corporate Secretary or any Assistant Secretary
and duly attested and sealed with the Company's seal by a Secretary or Assistant Secretary; or (b) duly executed (under seal, if required) by one or more
Attorneys -in -Fact and Agents pursuant to the power prescribed in his or her certificate or their certificates of authority or by one or more Company officers
pursuant to a written delegation of authority; and it is
FURTHER RESOLVED, that the signature of each of the following officers: President, any Executive Vice President, any Senior Vice President, any Vice
President, any Assistant Vice President, any Secretary, any Assistant Secretary, and the seal of the Company may be affixed by facsimile to any Power of
Attorney or to any certificate relating thereto appointing Resident Vice Presidents, Resident Assistant Secretaries or Attorneys -in -Fact for purposes only of
executing and attesting bonds and undertakings and other writings obligatory in the nature thereof, and any such Power of Attorney or certificate bearing
such facsimile signature or facsimile seal shall be valid and binding upon the Company and any such power so executed and certified by such facsimile
signature and facsimile seal shall be valid and binding on the Company in the future with respect to any bond or understanding to which it is attached.
I, Kevin E. Hughes, the undersigned, Assistant Secretary of Travelers Casualty and Surety Company of America, Travelers Casualty and Surety Company,
and St. Paul Fire and Marine Insurance Company, do hereby certify that the above and foregoing is a true and correct copy of the Power of Attorney
executed by said Companies, which will remain in full force and effect through December 31, 2018.
Kevin E. Hughes, Assistant Secretary
12 December 2017
Dated this day of
Ge
D
To verify the authenticity of this Power of Attorney, call I-800-421-3880 to contact us. Please refer to the Attorney -In -Fact number,
the above -named individual and the details of the bond to which the power is attached.
Prepared for:
Prepared by:
Board of Public Works
Rich Stopczynski
City of South Bend IN
Truck Centers, Inc.
County City Bldg.
10111 W, Sampde St.
South (Bend, IN 46601
South Bernd, IN 46619
Phone: 574-289-4065
rstopczynski@truckcenterslnc.com
Description
114SD CONVENTIONAL CHASSIS
2019 MODEL YEAR SPECIFIED
SET BACK AXLE - TRUCK
TRAILER TOWING PROVISION AT END OF
FRAME FOR TRUCK
LHI PRIMARY STEERING LOCATION
/
TRUCK/TRAILER CONFIGURATION
DOMICILED, USA (EXCLUDING CALIFORNIA AND
CARB OPT -IN STATES)
UTILITY/REPAIR/MAINTENANCE SERVICE
GOVERNMENT BUSINESS SEGMENT
DIRT/SAND/ROCK COMMODITY
TERRAIN/DUTY: 100% (ALL) OF THE TIME, IN
TRANSIT, IS SPENT ON PAVED ROADS
MAXIMUM 8% EXPECTED GRADE
ROUGH, MAINTAINED, CONCRETE OR ASPHALT
PAVEMENT- MOST SEVERE IN -TRANSIT
(BETWEEN SITES) ROAD SURFACE
FREIGHTLINER SID VOCATIONAL WARRANTY
EXPECTED FRONT AXLE RATING: 20,000 lbs.
EXPECTED REAR AXLE RATING: 46,000 lbs.
GROSS VEHICLE WEIGHT RATING: 66,000 lb&
i
i
/
/
/
SNOWPLOW, SALT SPREADER AND BELLY
PLOW BODY WITH HIGH GROUND CLEARANCE
EXPECTED TRUCK BODY LENGTH: 14.O ft,
EXPECTED TRUCK BODY WIDTH: 96.0 in
WA JONES TRUCK EQUIPMENT
SB121217A - Tandem Diesel Dump bid Page 1 of 13
Prepared for,
Board of Public Works
City of South Bend IN!
County City Bldg
South Bend, IN 46601
Prepared by:
Rich Stopczynski
Truck Centers, Inc.
1011 W. Sample St.
South (Bend, IN 46619
Phone: 574-289-4065
rstopozynskii@tru:ckcentersinc.com
Description
/ r
EQUIPMENT TRAILER
SINGLE (1) TRAILER
CUMMINS L9 300 HP @ 2000 RPM, 2200 GOV
RPM, 860 LBIFT TORQUE o@ 1300 RPM
r
/
/
/
65 MPH ROAD SPEED (LIMIT
CRUISE CONTROL SPEED LIMIT SAME AS ROAD
SPEED LIMIT
2016 ONBOARD IDIAGNOSTICSI2010
EPA/CARBIFINAL GHG17 CONFIGURATION
STANDARD OIL PAN
ENGINE MOUNTED OIL CHECK AND FILL
SIDE OF HOOD AIR INTAKE WITH FIREALL
MOUNTED DONALDSON AIR CLEANER WITH
SAFETY ELEMENT AND INSIDEIOUTSIDE AIR
WITH SNOW DOOR
DR 12V 160 AMP 36-St BRUSHLESS
QUADRAMOUNT PAD ALTERNATOR WITH
REMOTE BATTERY VOLT SENSE
(2) ALLIANCE MODEL 1231, GROUP 31,12 VOLT
MAINiTENANCE FREE 2250 CCA THREADED
STUD BATTERIES
BATTERY BOX WITH ALUMINUM COVER
MOUNTED SHORT SIDE TO RAIL
STANDARD BATTERY JUMPERS
LH BATTERY BOX MOUNTED AS FAR AFT AS
POSSIBLE, NO GREATER THAN 60 INCHES
BACK OF CAB
WIRE GROUND RETURN FOR BATTERY CABLES
WITH ADDITIONAL FRAME GROUND RETURN
NON -POLISHED BATTERY BOX COVER
CUMMINS TURBOCHARGED 18.7 CFM AIR
COMPRESSOR WITH INTERNAL SAFETY VALVE
ELECTRONIC ENGINE INTEGRAL SHUTDOWN
PROTECTION SYSTEM
RAISED RH OUTBOARD UNDER STEP
MOUNTED HORIZONTAL AFTEIRTREATMENT
SYSTEM ASSEMBLY WITH RH B-PILLAR
MOUNTED VERTICAL TAILPIPE
SB121217A - Tandem Diesel Dump bid Page 2 of 13
Prepared for:
Board of Public Works
City of South Bend IN
County City Bldg,
South Bend, IN 46601
Description
ENGINE AFTERTREATMENT DEVICE,
AUTOMATIC OVER THE ROAD REGENERATION
AND DASH MOUNTED REGENERATION
REQUEST SWITCH
10 FOOT 00 INCH (120 INCH+OI-5.9 INCH)
EXHAUST SYSTEM HEIGHT
RH CURVED VERTICAL TAILPIPE B-PILLAR
RAISED UNDER STEP MOUNTED
AFTERTREATMENT SYSTEM
6 GALLON DIESEL EXHAUST FLUID TANK
100 PERCENT DIESEL EXHAUST FLUID FILL
DIESEL EXHAUST FLUID PUMP MOUNTED AFT
OF DIESEL EXHAUST FLUID TANK
LH MEDIUM DUTY STANDARD DIESEL EXHAUST
FLUID TANK LOCATION
STANDARD DIESEL EXHAUST FLUID TANK CAP
STAINLESS STEEL AFTERTREATMENT
DEVICEIMUFFLERITAILPIPE SHIELD
HORTON DRIVEMASTER ADVANTAGE ONIOFF
FAN DRIVE
AUTOMATIC FAN CONTROL WITH DASH
SWITCH AND INDICATOR LIGHT, NON ENGINE
MOUNTED
CUMMINS SPIN ON FUEL FILTER
COMBINATION FULL FLOW/BYPASS OIL FILTER
1300 SQUARE INCH ALUMINUM RADIATOR
ANTIFREEZE TO -34F, OAT (NITRITE AND
SILICATE FREE) EXTENDED LIFE COOLANT
GATES BLUE STRIPE COOLANT HOSES OR
EQUIVALENT
CONSTANT TENSION HOSE CLAMPS FOR
COOLANT HOSES
RADIATOR DRAIN VALVE
1350 ADAPTER FLANGE FOR FRONT PTO
PROVISION
PHILLIPS-TEMRO 1000 WATT/115 VOLT BLOCK
HEATER
CHROME ENGINE HEATER RECEPTACLE
MOUNTED UNDER LH DOOR
ELECTRIC GRID AIR INTAKE WARMER
DELCO 12V 38MT HD STARTER WITH
INTEGRATED MAGNETIC SWITCH
Prepared by:
Rich Stopczynski
Truck Centers, Inc.
1011 W. Sample St.
South Bend, IN 46619
Phone: 574-289-4065
rstopczynski@truckcentersinc.com
SB121217A - Tandem Diesel Dump bid Page 3 of 13
Prepared for:
Board of Public Works
City of South Bend IN
County City Bldg.
South Bend, IN 46601
Description
ALLISON 3500 RIDS AUTOMATIC TRANSMISSION
WITH PTO PROVISION
VEHICLE INTERFACE WIRING CONNECTOR
WITH PDM AND BLUNT CUTS, INSIDE CAB
ELECTRONIC TR'ANSMISSIlON CUSTOMER
ACCESS CONNECTOR FIREWALL MOUNTED
MAGNETIIC PLUGS, ENGIINE DRAIN,
TRANSMISSION DRAIN, AXLE(S) FALL AND
DRAIN
PUSH BUTTON ELECTRONIC SHIFT CONTROL,
DASH MOUNTED
TRANSMISSION PROGNOSTICS - ENABLED 2013
WATER TO OIL TRANSMISSION COOLER, IN
RADIATOR END TANK
TRANSMISSION OIL CHECK AND FILL WITH
ELECTRONIC OIL LEVEL CHECK
SYNTHETIC TRANSMISSION FLUID (TES-295
COMPLIANT)
DETROIT DA-F-20.0-5 20,000# FIL1 71.0 KPI/3.74
DROP SINGLE FRONT AXLE
MERITOR 16.5X6 Q+ CAST SPIDER CAM FRONT
BRAKES, DOUBLE ANCHOR, FABRICATED
SHOES
NON -ASBESTOS FRONT (BRAKE LINING
CONMET CAST IRON FRONT BRAKE DRUMS
FRONT BRAKE DUST SHIELD'S
FRONT OIL SEALS
VENTED FRONT HUB CAIPS WITH WINDOW,
CENTER AND SIDE PLUGS - OIL
STANDARD SPINDLE NUTS FOR ALL AXLES
HALDEX AUTOMATIC FRONT SLACK
ADJUSTERS
STANDARD KING PIN BUSHINGS
TRW THP-0 POWER STEERING WITH RCH45
AUXILIARY GEAR
POWER STEERING PUMP
4 QUART POWER STEERING RESERVOIR
OIL/AI,R POWER STEERING COOLER
ORGANIC SAE 80/90 FRONT AXLE ILUBE
Prepared) by:
Rich Stopozynski
Truck Centers, Inc.
1011 W. Sample St.
South. Bend, IN 46619
Phone: 574-289-4065
rstopczynski@truckcentersinic.com
SB121217A - Tandem Diesel Dump bM Page 4 of 13
Prepared for
Board of Public Works
City of South Bend IN
County City Bldg,
South Bend, IN 46601
Description
20,000# FLAT LEAF FRONT SUSPENSION
GRAPHITE BRONZE BUSHINGS WITH SEALS -
FRONT SUSPENSION
FRONT SHOCK ABSORBERS
RT-46-160 46,000# R-SERIES TANDEM REAR
AXLE,
6.14 (REAR AXLE RATIO
IRON REAR AXLE CARRIER WITH STANDARD
AXLE HOUSING
MXL 17T MIERITOR EXTENDED LURE MAIN
DRIVELINE WITH HALF ROUND YOKES
MXL 17T MEIRITOR EXTENDED LU'BE INTERAXLE
DRIVELINE WITH HALF ROUND YOKES
(1) INTERAXLE LOCK VALVE FOR TANDEM OR
TRIDEM DRIVE AXLES
BLINKING LAMP WITH EACH INTERAXLE LOCK
SWITCH, INTERAXLE UNLOCK DEFAULT WITH
IGNITION OFF
MERITOR 16.5X Q+ CAST SPIDER CAM REAR
BRAKES, DOUBLE ANCHOR, FABRICATED
SHOES
NON -ASBESTOS REAR BRAKE LINING
ASPHALT SPREADER CLEARANCE REAR
BRAKE GEOMETRY
CONMET CAST IRON REAR BRAKE DRUMS
REAR BRAKE DUST SHIELDS
REAR OIL SEALS
BENDIX EVER SURE LONGSTROKE 2-DRIVE
AXLES SPRING PARKING CHAMBERS
HALDEX AUTOMATIC REAR SLACK ADJUSTERS
ORGANIC SAE 80/90 REAR AXLE LURE
STANDARD REAR AXLE BREATHER(S)
HENIDRICKSON HN462 @a 46,000# REAR
SUSPENSION
HENDRICKSON HIN 400/460 - 9.56 INCH RIDE
HEIGHT
STANDARD AXLE SEATS IN AXLE CLAMP
GROUP
52 INCH AXLE SPACING
Prepared by:
Rich Stopczynski
Truck Centers., Inc.
1011 W. Sample St.
South Bend, IN 46619
Phone: 574-289-4065
rstopczynski c@truckcentersinc.com
SB121217A - Tandem Diesel Dump bid Page 5 of 13
Prepared for:
Board of Public Works
City of South Bend IN
County City Bldg,
South Bend, IN 46601
Prepared by:
Rich Stopozynski
Truck Centers, Inc.
1011 W. Sample St.
South Bend, IN 46619
Phone: 574-2894065
rstopczynski@truckoentersino.com
Description
HENDRICKSON HN, HAULMAAX AND UILTIMAAX
SERIES STEEL BEAMS WITH BAR PIN
FORE/AFT AND TRANSVERSE CONTROL RODS
REAR SHOCK ABSORBERS - TWO AXLES
(TANDEM)
1/111004#01r I
WABCO 4S14M ABS WITHOUT TRACTION
CONTROL
REINFORCED NYLON, FABRIC BRAID AND WIRE
BRAID CHASSIS AIR LINES
FIBER BRAID PARKING BRAKE HOSE
STANDARD BRAKE SYSTEM VALVES
STANDARD AIR SYSTEM PRESSURE
PROTECTION SYSTEM
STD, U.S. FRONT BRAKE VALVE
RELAY VALVE WITH 5-8 PSI CRACK PRESSURE,
NO REAR PROPORTIONING VALVE
WABCO SS-1200 PLUS AIR DRYER WITH
INTEGRAL AIR GOVERNOR AND HEATER
WABCO OIL COALESCING FILTER FOR AIR
DRYER
AIR DRYER MOUNTED OUTBOARD ON RH RAIL
STEEL AIR TANKS MOUNTED FOR MAX
GROUND CLEARANCE
PULL CABLE ON WET TANK, PETCOCK DRAIN
VALVES ON ALL OTHER AIR TANKS
YEMEN
AIR CONNECTIONS TO END OF FRAME WITH
GLAD HANDS FOR TRUCK AND DUST COVERS
PRIMARY RECEPTACLE CENTER PIN WIRED TO
BACKUP LIGHT CIRCUIT WITH STOP SIGNAL
PREWI RE PACKAGE
SAE J560 7-WAY PRIMARY TRAILER CABLE
RECEPTACLE MOUNTED END OF FRAME
UPGRADED CHASSIS MULTIPLEXING UNIT
SUPPLEMENTAL J560 7-WAY RECEPTACLE
LOCATED WITH PRIMARY RECEPTACLE
11111110/11/so
4800MM (189 INCH) WHEELBASE
7/16X3-9/16X11-1/8 INCH STEEL FRAME
(11.1 11MMX282.6MM/0.437Xl 1.13 INCH) 120K PSI
1/4 INCH (6.35MM) C-CHANNEL INNER FRAME
REINFORCEMENT (31,0 SECTION MODULUS
AND 3,715,000 RBM RATINGS)
SB121217A - Tandem Diesel Dump, bid Page 6 of 13
Prepared for:
Board of Public Works
City of South Bend IN
County City Bldg.
South Bend, IN 46601
Prepared by:
Rich Stopczynski
Truck Centers, Inc.
1011 W. Sample St.
South Bend, IN 46619
Phone: 574-289-4065
rstopczynskitruckcentersinc.com
Description
1600MIW (63 INCH) REAR FRAME OVERHANG
24 INCH INTEGRAL FRONT FRAME EXTENSION
WITH 0.25 INCH INSERT
CALCULATED EFFECTIVE BACK OF CAB TO
REAR SUSPENSION CIL (CA) : 120.45 in
SQUARE END OF FRAME
FRONT CLOSING CROSSMEMBER
STANDARD WEIGHT ENGINE CROSSMEMBER
STANDARD MIDSHIP #1 CROSSMEMBER(S)
REARMOST CROSSMEMBER MOUNTED WITH
LAST CROSSMEMBER 13 INCHES FROM END
OF FRAME
HEAVY DUTY SUSPENSION CROSSMEMBER
14 INCH PAINTED STEEL SEVERE DUTY
BUMPER
BUMPER MOUNTING FOR SINGLE LICENSE
PLATE
HUCK-'SPIN ROUND COLLAR CHASSIS
FASTENERS SUSPENSION'S ONLY
60 GALLON1227 LITER RECTANGULAR
ALUMINUM FUEL TANK - LHI
RECTANGULAR FUEL TANK
PLAIN ALUMINUM FUEL TANK WITH PAINTED
BANDS
FUEL TANK FORWARD - RAISED MOUNTING
PLAIN STEP (FINISH
FUEL TANK CAP
DETROIT FUELMATER SEPARATOR WITH
WATER IN FUEL SENSOR, HAND PRIMER AND
12 VOLT PREHEATER
EQUIFILO INBOARD FUEL SYSTEM
HIGH TEMPERATURE REINFORCED NYLON
FUEL LINE
INSULATION FOR FUEL LINES
i
MICHELIN XZU-S2 315180R22.5 20 PLY RADIAL
FRONT TIRES
MICHELIN X WORKS XDY 11 R22.5 16 PLY
RADIAL REAR TIRES
SB'121217A - Tandem Diesel Dump bid Page 7 of 13
Prepared for:
Board of Public Works
City of South Bend IN
County City Bldg.
South Bend, IN 46601
Description
CONIMET PRESET PLUS PREMIUM IRON FRONT
HUBS
CONMET PRESET PLUS PREMIUM IRON REAR
HUBS
ACCURIDE 29039 22.5X9.00 10-HUB PILOT 5.25
INSET 5-HAND STEEL DISC FRONT WHEELS
ACCURIDE 28828 22.5X8.25 10-HUB PILOT 2-
HAND HD STEEL DISC REAR WHEELS
114 INCH BBC FLAT ROOF ALUMINUM
CONVENTIONAL CAB
AIR CAB MOUNTING
NIONREMOVABLE BUGSCREEN MOUNTED
BEHIND GRILLE
SHORT FENDER WITH MUDFLAP
BOLT -ON MOLDED FLEXIBLE FENDER
EXTENSIONS
LH AND RH GRAB HANDLES
BRIGHT FINISH RADIATOR SHEILLIHOOD BEZEL
STATIONARY BLACK GRILLE WITH BRIGHT
ACCENTS
CHROME HOOD MOUNTED AIR INTAKE GRILLE
FIBERGLASS HOOD
DUAL 14 INCH ROUND POLISHED AIR HORNS
DUAL ELECTRIC HORNS
DUAL HORN SHIELDS
DOOR LOCKS AND IGNITION SWITCH KEYED
THE SAME
HALOGEN COMPOSITE HEADLAMPS WITH
BRIGHT BEZELS
LIED AERODYNAMIC MARKER LIGHTS
INTEGRAL STOPtTAIUBACKUP LIGHTS WITH 7
EXTRA FEET OF WIRE MOUNTED AT END OF
FRAME
STANDARD FRONT TURN SIGNAL LAMPS
DUAL WEST COAST BRIGHT FINISH HEATED
MIRRORS WITH LHAND RH REMOTE
DOOR MOUNTED MIRRORS
102 INCH EQUIPMENT WIDTH
Prepared by.
Ruch Stopczynski
Truck Centers, Inc.
1011 W. Sample St.
South Bend, IN 46619
Phone: 574-289-4065
rstopczynski@truckoentersinc.com
truckoentersinc.com
SB121217A - Tandem Diesel Dump bid Page 8 of 13
Prepared for,
Board of Public Works
City of South Bend IN
County City Bldg,
South Bend, IN 46601
Description
LH AND RH 8 INCH BRIGHT FINISH CONVEX.
MIRRORS MOUNTED UNDER PRIMARY
MIRRORS
STANDARD SIDEIREAR REFLECTORS
FIXED CAB MOUNTED STEPS LH AND RH FOR
CAB ENTRY, BELLY PLOW BODY WITH HIGH
GROUND CLEARANCE
63X14 INCH TINTED REAR WINDOW
TINTED DOOR GLASS LH AND RH WITH TINTED
NON -OPERATING WING WINDOWS
RH AND LH ELECTRIC (POWERED WINDOWS,
PASSENGER SWITCHES ON' D,OOR(S)
TINTED WINDSHIELD
2 GALLON WINDSHIELD WASHER RESERVOIR
WITHOUT FLUID LEVEL INDICATOR, FRAME
MOUNTED
OPAL GRAY VINYL INTERIOR
MOLDED PLASTIC DOOR PANEL WITHOUT
VINYL INSERT WITH ALUMINUM IKICKPLATE
LOWER DOOR
MOLDED PLASTIC DOOR (PANEL WITHOUT
VINYL INSERT WITH ALUMINUM KICKPLATE
LOWER DOOR
BLACK (MATS WITH SINGLE INSULATION
DASH MOUNTED ASH TRAY
FORWARD ROOF MOUNTED CONSOLE WITH
UPPER STORAGE COMPARTMENTS WITHOUT
NETTING
IN DASH STORAGE BIN
(2) CUP HOLDERS LH AND RH DASH
GRAY/CHARCOAL FLAT DASH
SMART SWITCH EXPANSION MODULE
HEATER, DEFROSTER AND AIR CONDITIONER.
STANDARD HVAC DUCTING WITH SNOW
SHIELD FOR FRESH AIR INTAKE
MAIN HVAC CONTROLS WITH RECIRCULATION
SWITCH
STANDARD HEATER PLUMBING
DENSO HEAVY DUTY AIR CONDITIONER
COMPRESSOR
BINARY CONTROL, R-134A
STANDARD INSULATION
Prepared by:
Rich Stopczynski
Truck Centers, Inc.
1011 W. Sample St.
South Bend, IN 46619
Phone: 574-289-4065
rstopozynski@truckcenterslnc.com
S13121217A -Tandem Diesel Dump bid Page 9 of 13
Preparedfor:
Board' of Public Works
City of South Bend IN
County City (Bldg.
South Bend, IN 46601
Prepared by:
Rich Stopczynski
Truck Centers, Inc.
1011 W. Sample St..
South Bend, IN 46619
Phone: 574-289-4065
rstopczynski@truckcentersinc.com
Description
SOLID-STATE CIRCUIT PROTECTION AND
FUSES
12V NEGATIVE GROUND ELECTRICAL SYSTEM
DOME (DOOR ACTIVATED LH AND RH, DUAL
READING LIGHTS, FORWARD CAB ROOF
LH AND RHI ELECTRIC DOOR LOCKS
(1) 12 VOLT (POWER SUPPLY IN DASH
PREMIUM HIGH BACK AIR SUSPENSION DRIVER
SEAT WITH 3 CHAMBER AIIR LUMBAR,
INTEGRATED CUSHION EXTENSION, FORWARD
AND REAR CUSHION TIILT, ADJUSTABLE SHOCK
ABSORBER
BASIC HIGH BACK NON SUSPENSION
PASSENGER SEAT
DUAL DRIVER SEAT ARMRESTS, NO
PASSENGER SEAT ARMRESTS
LH AND RH INTEGRAL DOOR PANEL ARMRESTS
VINYL WITH VINYL INSERT DRIVER SEAT
VINYL WITH VINYL INSERT PASSENGER SEAT
BLACK SEAT BELTS
ADJUSTABLE TILT AND TELESCOPING
STEERING COLUMN
4-SPOKE 18 INCH (450MM) STEERING WHEEL
DRIVER AND PASSENGER INTERIOR SUN
VISORS
MINN
GRAY DRIVER INSTRUMENT PANEL
GRAY CENTER INSTRUMENT PANEL
BLACK GAUGE BEZELS
LOW AIR PRESSURE INDICATOR LIGHT AND
AUDIBLE ALARM
2 INCH PRIMARY AND SECONDARY AIR
PRESSURE GAUGES
INTAKE MOUNTED AIR RESTRICTION
INDICATOR WITHOUT GRADUATIONS
97 DB BACKUP ALARM MOUNTED INBOARD OF
RAIL
ELECTRONIC CRUISE CONTROL WITH
SWITCHES IN LH SWITCH PANEL
KEY OPERATED IGNITION SWITCH AND
INTEGRAL START POSITION; 4 POSITION
OFF/RUN/START/ACCESSORY
ICU3S, 132X48 DISPLAY WITH DIAGNOSTICS, 28
LED WARNING LAMPS AND DATA LINKED
513121217A - Tandem Diesel Dump bid Page 10 of 13
Prepared for:
Board of Public Works
City of South Bend IN
County City Bldg.
South Bend, IN 46601
Description
HEAVY DUTY ONBOARD DIAGNOSTICS
INTERFACE CONNECTOR LOCATED BELOW LH
DASH
2 INCH ELECTRIC FUEL GAUGE
PROGRAMMABLE RPM CONTROL -
ELECTRONIC ENGINE
ELECTRICAL ENGINE COOLANT TEMPERATURE
GAUGE
2 INCH TRANSMISSION OIL TEMPERATURE
GAUGE
ENGINE AND TRIP HOUR METERS INTEGRAL
WITHIN DRIVER DISPLAY
ELECTRIC ENGINE OIL PRESSURE GAUGE
OVERHEAD INSTRUMENT PANEL
AMIFMIWB WORLD TUNER RADIO WITH CD
PLAYER, BLUETOOTH, IPOD INTERFACE, USB
AND AUXILIARY INPUTS, J1939
DASH MOUNTED RADIO
(2) RADIO SPEAKERS IN CAB
AMIFM ANTENNA MOUNTED ON FORWARD LH
ROOF
POWER AND GROUND STUDS INIUNDER DASH
ELECTRONIC MPH SPEEDOMETER WITH
SECONDARY KPH SCALE, WITHOUT
ODOMETER
STANDARD VEHICLE SPEED SENSOR
ELECTRONIC 3000 RPM TACHOMETER
NO VEHICLE PERFORMANCE MONITOR
NO DETROIT CONNECT SERVICES SELECTED
NO ZONAR SERVICES SELECTED
IGNITION SWITCH CONTROLLED ENGINE STOP
(6) IGN CONTROLLED EXTRA SWITCHES WITH
IND LIGHTS WIRED TO POWER DIST BOX WITH
RELAYS PROVIDING 20 AMPS PER CIRCUIT TO
JUNCTION BLOCK AND 1 CIRCUIT AT 30 AMPS
PRE -TRIP LAMP INSPECTION, ALL OUTPUTS
FLASH, WITH SMART SWITCH
BW TRACTOR PROTECTION VALVE
TRAILER HAND CONTROL BRAKE VALVE
DIGITAL VOLTAGE DISPLAY INTEGRAL WITH
DRIVER DISPLAY
SINGLE ELECTRIC WINDSHIELD WIPER MOTOR
WITH DELAY
Prepared by:
Rich Stopczynski
Truck Centers, Inc.
1011 W. Sample St.
South Bend, IN 46619
Phone: 574-289-4065
rtopczynski@truckcentersinc.com
SB121217A-Tandem Diesel Dump bid Pagel 1 of 13
Prepared for:
Board of Public Works
City of South Bend IN
County City Bldg,
South Bernd„ IN 46601
Description
MARKER LIGHT SWITCH INTEGRAL WITH
HIEADUGHT SWITCH AND DUAL CONNECTORS
AND SWITCH FOR CUSTOMER FURNISHED
SNOW PLOW LIGHTS, LOW BEAMS OFF WITH
HIGH BEAMS
TWO VALVE PARKING BRAKE SYSTEM WITH
DASH VALVE CONTROL AUTON'EUTRAL AND
WARNING INDICATOR
SELF CANCELING TURN SIGNAL SWITCH WITH
DIMMER, WASHERIWIPER AND HAZARD IN
HANDLE
Prepared by:
Rich S topczynski
Truck Centers, Inc.
1011 W. Sample St.
South Bend, IN E46619
Phone: 574-269-4065
rstopczynski@truckcentersinc.com
(INTEGRAL ELECTRONIC TURN SIGNAL
FLASHER WITH HAZARD LAMPS OVERRIDING
STOP LAMPS
PAIINT: ONE SOLID COLOR
/ r
CAB COLOR A: L0006EB WHITE ELITE BC
BLACK, HIGH SOLIDS POLYURETHANE CHASSIS
PAINT
POWDER WHITE (N0006EA) FRONT WHEELS
POWDER WHITE (N0006EA) REAR WHEELS
STANDARD BLACK IBUMPER PAINT
STANDARD E COAT/UNDERCOATING
U.S. FMVSS CERTIFICATION
CiUMMINS L9 ENGINE WARRANTY:
5 YEARS / 150,000 MILES / 100% PARTS AND LABOR
CUMMINS AFTERTREATMENT WARRANTY:
5 YEARS / 150,000 MILES 1100% PARTS AND LABOR
ALLISON TRANSMISSION WARRANTY:
5 YEARS/UNLIMITED MILES / 100% PARTS AND LABOR
SB121217A - Tandem Diesel Dump bid Page 12 of 13
Prepared for:
Board of Public Works
City of South Bend IN
County City Bldg.
South Bend, IN 46601
20A FEED AND GROUND, 15A iGNITION FEED
DASH CENTER WITH 2'WIRE HARNESS
ZiEBART RUSTPROOFING WITH WARRANTY
MANUALS FOR ALL EQUIPMENT
1 YEAR SUBSCRIPTION - TROUBLESHOOTING
SOFTWARE
ACCESS TO PARTS AND SERVICE ONLINE
Prepared by:
Rich Stopozynski
Truck Centers, inc.
1011 W. Sample St.
South Bend, IN 46619
Phone: 574-289-4065
rstopczynski@truir,koentersinc.com
SB1211217A - Tandem Diesel Dump bid Page 13 of 13