Loading...
HomeMy WebLinkAboutOpening of Bids - Spec AF - One or More 2017 or Newer Tandem Axle Dump Truck - Truck Centers, Inc. - dba Hill Truck SalesCITY OF SOUTH BEND, INDIANA SELLER'S BID FOR SALE OR LEASE OF MATERIALS AND NON -COLLUSION AND NON! DEBARMENT AFFIDAVIT AND NON-DISCRIMINATION COMMITMENT FOR SELLERS BID NAME Spec AF — One (1) or More 2017 or Newer Tandem Axle Dump Truck FOR BIDS, DUE December 12, 2017 at 9:30 a.m. Bidder Date: December 11, 2017 (Firm): Truck Centers, Inc, d/b/a Hil'II Truck Sales Address: 1011 W. Sample St, South Bend, IN 46619 City/State/Zip: South Bend IN 46619 Telephone Number: (574) 2891-4065 Agent of Bidder (if Applicable): Rich Stopczynski, Sales Executive When the prospective Contractor is unable to certify to any of the statements below, it shall attach (tit explanation to this Affidavit, CONTRACTOR'S NON -COLLUSION AND NON -DEBARMENT AFFIDAVIT, CERTIFICATION REGARDING INVESTMENT WITH IRAN, EMPLOYMENT ELIGIBILITY VERIFICATION, NON-DISCRIMINATION COMMITMENT AND CERTIFICATION OF USE OF UNITED STATES STEEL PRODUCTS OR FOUNDRY PRODUCTS (Must be completed for all quotes and bids. Please type or print) STATE OF IN ) SS: St. Joe COUNTY The undersigned Contractor, being duly sworn upon his/her/its oath, affirms under the penalties of pctjury that: 1, Contractor has not, nor has any other member, representative, or agent of the firm, company, corporation or partnership represented by him, entered into any combination, collusion or agreement with any person relative to the price to be bid by anyone at such letting nor to prevent any person from bidding nor to induce anyone to refrain from bidding, and that this bid is made without reference to any other bid and without any agreement, understanding or combination with any other person in reference to such bidding. Contractor further says that no, person or persons, firms, or corporation has, have or will receive directly or indirectly, any rebate, fee, gift, commission or thing of value on account of such sale; and 2. Contractor certifies by submission of this proposal that neither contractor nor any of its principals are presently debarred, suspended, proposed for debarment, declared ineligible, or voluntarily excluded from participation in this transaction by any Federal department or agency; and 3. Contractor has not, nor has any successor to, nor an affiliate of, Conti -actor, engaged in investment activities in Iran. 0 a. For purposes of this Certification, "Iran" means the government of Iran and any agency or instrumentality of Iran, or as otherwise defined at Ind. Code § 5-22-16.5-5, as amended from time -to -time. b. As provided by Ind. Code § 5-22-16.5-8, as amended from time -to -time, a Contractor is engaged in investment activities in Iran if either: i. Contractor, its successor or its affiliate, provides goods or services of twenty million dollars ($20,000,000) or more in value in the energy sector of Iran; or ii. Contractor, its successor or its affiliate, is a financial institution that extends twenty million dollars ($20,000,000) or more in credit to another person for forty-five (45) days or more, if that person will (i) use the credit to provides goods and services in the energy sector in Iran; and (ii) at the time the financial institution extends credit, is a person identified on list published by the Indiana Department of Administration. 4. Contractor does not knowingly employ or contract with an unauthorized alien, nor retain any employee or contract with a person that the Contractor subsequently learns is an unauthorized alien. Contractor agrees that he/she/it shall enroll in and verify the work eligibility status of all of Contractor's newly hired employees through the E-Verify Program as defined by I.C. 22-5-1.7-3. Contractor's documentation of enrollment and participation in the E-Verify Program is included and attached as part of this bid/quote; and 5. Contractor shall require his/her/its subcontractors performing work under this public contract to certify that the subcontractors do not knowingly employ or contract with an unauthorized alien, nor retain any employee or contract with a person that the subcontractor subsequently learns is an unauthorized alien, and that the subcontractor has enrolled in and is participating in the E-Verify Program. The Contractor agrees to maintain this certification throughout the term of the contract with the City of South Bend, and understands that the City may terminate the contract for default if the Contractor fails to cure a breach of this provision no later than thirty (30) days after being notified by the City. 6. Persons, partnerships, corporations, associations, or joint venturers awarded a contract by the City of South Bend through its agencies, boards, or commissions shall not discriminate against any employee or applicant for employment in the performance of a City contract with respect to hire, tenure, terms, conditions, or privileges of employment, or any matter directly or indirectly related to employment because of race, sex, religion, color, national origin, ancestry, age, gender expression, gender identity, sexual orientation or disability that does not affect that person's ability to perform the work. In awarding contracts for the purchase of work, labor, services, supplies, equipment, materials, or any combination of the foregoing including, but not limited to, public works contracts awarded under public bidding laws or other contracts in which public bids are not required by law, the City, its agencies, boards, or commissions may consider the Contractor's good faith efforts to obtain participation by those Contractors certified by the State of Indiana as a Minority Business ("MBE") or as a Women's Business Enterprise ("WBE") as a factor in determining the lowest, responsible, responsive bidder. In no event shall persons or entities seeking the award of a City contract be required to award a subcontract to an MBE/WBE; however, it may not unlawfully discriminate against said WBE/MBE. A finding of a discriminatory practice by the City's MBEIWBE Utilization Board shall prohibit that person or entity from being awarded a City contract for a period of one (1) year from the date of such determination, and such determination may also be grounds for terminating the contact for which the discriminatory practice or noncompliance pertains. 7. The undersigned contractor agrees that the following nondiscrimination commitment shall be made a part of any contract which it may henceforth enter into with the City of South Bend, Indiana or any of its agencies, boards or commissions. Contractor agrees not to discriminate against or intimidate any employee or applicant for employment in the performance of this contract with privileges of employment, or any matter directly or indirectly related to employment, because of race, religion, color, sex, gender expression, gender identity, sexual orientation, handicap, national origin or ancestry. Breach of this provision may be regarded as material breach of contract. I, the undersigned bidder or agent as contractor on a public works project, understand my statutory obligations to the use of steel products or foundry products made in the United States (I.C. 5-16-5-1). I hereby certify that I and all subcontractors employed by me for this project will use steel products or foundry products made in the United States on this project if awarded. I understand I have an affirmative duty to notify the City in my bid that my proposal does not include the use of steel products or foundry products made in the United States. I understand it is my sole obligation and responsibility to provide a justification to the City, subject to review and approval, why the cost of United States made steel or foundry products is unreasonable. Prior to award and upon submission of bid which does not use steel products or foundry products made in the United States, the City, through its director of public works, shall make a determination if the price of United States made steel or foundry is unreasonable. I understand that violations hereunder may result in forfeiture of contractual payments. In I hereby affirm under the penalties of perjury that the facts and information contained in the foregoing bid for public works are true and correct. Dated this 1 lth day of December, 20 17 Truck Centers Inc. d/b/a Hill Truck Sales Contractor/Bidder (Firm) Signature of nt • o Bidder or Its Agent Rich Stopczynski, Sales Executive Printed Name and Title Subscribed and sworn to before me this day of Oe, 20f_U- My Commission Expires �yIGt Ua U (, AAvU lu= otary Public =PublicALBERQA Notary Seal County of Residence S ju:)Cy) dianaCountyires May 9, 2024 11 (To be completed only by Contractors/Bidders clairtting to be a `local Indiana business " purstlant to I.C. 36-1-12-22) INDIANA LOCAL BUSINESS PREFERENCE CLAIM A "local Indiana business" refers to any of the following: (1) A business whose principal place of business is located in an affected county. (2) A business that pays a majority of its payroll (in dollar voluine) to residents of affected counties. (3) A business that employs residents of affected counties as a majority of its employees. (4) A business that makes significant capital investments in the affected counties as defined in rules adopted by the political subdivision. (5) A business that has a substantial positive economic impact on the affected counties as defined by criteria in rules adopted by the political subdivision. An "affected county" refers to St. Joseph Cozinty, Indiana, or the following counties located adjacent to St. Joseph County: Elkhart County, Marshall County, Starke County and LaPorte County There are the following price preferences for supplies purchased from a local Indiana business: • 5% for a purchase expected by the purchasing agency to be less than $50, 000 • 3% for a purchase expected by the purchasing agency to beat least $50,000 but less than $100, 000. • 1 % for a purchase expected by the purchasing agency to beat least $100, 000. Date: December 11, 2017 Pursuant to I.C. 36-1-12-22, Truck Centers Inc. d/b/a Hill Truck Sales claims a local Indiana business preference for Project _Tandem Axle Dump Truck (Project # __ pec AF ) located within the City of South Bend, St. Joseph County, Indiana. ❑ The location of the principal place of business is �1011 W. Sample St, South Bend, IN 46619 (Address) ❑ St. Joseph County, Indiana ❑ The following county located adjacent to St. Joseph County, Indiana: ❑ The majority of the business's payroll for the 12 months prior to the date of this Bid is to residents of St. Joseph County, Indiana or the adjacent county noted above. ❑ The majority of the business's employees for the 12 months prior to the date of this Bid are residents of St. Joseph County, Indiana, or the adjacent county noted above. If the business is deemed to be the apparent lowest, responsible, responsive bidder, then it shall provide supporting documentation for the 12 month period prior to the date of the Bid of (i) the total payroll amount paid to all employees of the business, and (ii) the total payroll amount paid to employees who are residents of St. Joseph County and the adjacent county noted above. WHEN SUPPLYING SUPPORTING PAYROLL RECORDS, BIDDER SHALL REDACTALL SOCIAL SECURITYNUMBERS. Dated this 1 lth day of December I l , 20 17 Truck Centers, Inc. d/b/a Hill Truck Sales Cont c p Bidder (Firm) ignature otto jqct •/Bidder or Its Agent Rich Stonczvnski. Sales Executive Printed Name and Title Filled in by "fruck Centers lane:'. BID NAME Spec AF — One (1) or More 2017 or Newer Tandem Axle Dump Truck FOR BIDS DUE December 12,2017 at 9:30 a.m. Pursuant to notices given, the undersigned offers bids) to the City of South Bend in accordance with the following attachment(s) which specify the class or item number or description, quantity, unit, unit price. SPEC AF — ONE (1) OR MORE 2017 OR NEWER TANDEM AXLE DUMP TRUCK It is the intent of these specifications to describe a vehicle or piece of equipment for the City of South Bend. The unit shall be bid as a fully equipped complete unit as set out in the attached specifications. No partial or split bids will be accepted. Unit to be bid with and without trade-in if applicable. Vendor to complete bid proposal contained in this bid specification and attach to the submitted bid. These are minimum specifications. Any variation from the specifications must be spelled out on a separate deviation list in order for the bid to be valid. Any items not listed on the deviation sheet will be assumed to be part of the unit. Proprietary products or specific manufacturers may be referenced herein. Such references are only made to demonstrate minimum scope, quality, and style of the equipment desired. Equipment that is bid pursuant to these specifications shall be of equal quality and size, or greater', to those referenced, and are subject to approval by the South Bend Board of Public Works. Vendor shall provide all information requested in specifications to qualify for bid. If information on brochure submitted does not completely cover specifications requested, it shall be typed and attached to brochure. If an alternate is included within these specifications, please be advised that, alternate items placed in the specifications are to determine the best configuration of the item within a budgeted amount and may be included in the award criteria, If the Board elects to award one or more (s), the base bid price and the alternate bid price(s) will be totaled and compared for all bidders offering the final configuration. Award will be made based on the lowest responsible/responsive bid prices submitted for the base bid with selected (s), if applicable. Failure to submit a bid on an alternate may result in the entire bid being non -responsive, depending on the final configuration of the product. Payment will be processed once the unit is inspected and accepted as to meeting the specifications by the Division of Central Services. This will include all manuals and warranty documentation. 9 Prepared for: Board of Public Works City of South Bend IN County City Bldg. South Bend, IN 46601 The following components deviate from listed specifications: Prepared by: Rich Stopczynski Truck Centers, Inc. 1011 WEST SAMPLE STREET SOUTH BEND, IN 46619 Phone:574-289-4065 stopczynski@truckcentersinc.com Page 12 — Cooling: The radiator is designed with a steel reinforced conduit, through which the PTO shaft passes and connects to the crankshaft This allows the engine to be placed lower in the chassis, thereby dropping the hood height, and allowing for maximum visibility for the driver. All other components meet or exceed minimum specifications. Submitted by: Rich Stopcz nski Sales Executive SB121217A - Tandem Diesel Dump bid Page 1 of 1 Bidder must state as accurately as possible an intended delivery date from the date of the bid award. Due to the age of the City's existing fleet, it is imperative that the unit's be delivered as quickly as possible. Stated delivery lead time may be included as an integral part of our bid selection process. FOB Central Services. The unit and all related paperwork is to be delivered to: Central Services Division 1045 West Sample Street South Bend, Indiana 46619 All Certificates of Origin/Title Work shall list the owner as: The City of South Bend 1045 West Sample Street South Bend, Indiana 46619 The Board will award the bid to the lowest responsible and responsive bidder. If the bid is not awarded to the lowest bidder, the factors used to justify the awards will be stated in writing at the request of any bidder. The Board reserves the right to reject any and/or all bids or portions thereof and to waive any irregularities or informalities. SHALL BE AS `> DESCRIPTION SPECIFIED TYPE (Circle One).: Chassis: Conventional cab chassis with a cab to axle dimension of 120". YE / NO Maximum of 199" wheel base, ground clearance minimum of 23" for underbody mounting. Front Axle: 20,000 lb. capacity YES NO Rear Axle: 46,000 lb. capacity, Rockwell SQHP or equal, geared for 65 mph YES NO top speed. Front 20,000 lb. capacity, Heavy duty shock absorbers YES NO Suspension: Rear Hendrickson HN-402-52 or equal rubber suspension and YES NO Suspension: transverse torque rods. Severe service suspension equaling 46,000 lbs. 10 TYPE . DESCRIPTION Tires Ten (10) hub piloted disc type wheels: 315/80R22.5. Front & Wheels: Tire 20 ply radials Good Year G286 or equal. Rear tires 11R22.5 16 ply Good Year G338 or equal, tubeless radials. Engine: Turbo -charged, inline six cylinder electronic controlled diesel engine. Minimum horse power 300, at 860 ft. lbs. of torque, air to air after cooler required, emergency shutdown system for low oil, high coolant temperature. Provisions for front mounted crankshaft P.T.O. including flange for adapting to front mounted pump, fuel/water separator. Air cleaner to be dry type, two stage with provision to pull intake air from under hood. Air cleaner to include restriction indicator. All hoses to be silicone. Severe service material and hose clamps to be constant tension type. 1000 watt engine block heater included. Electronic Fan Clutch with manual over ride switch. Engine and engine electronics warranty to be 5 year/150,000 miles. YES NO YES / NO Transmission: Allison 3,500 RDS, five speed electronic automatic, furnished with OESNO transmission temperature gauge, auxiliary oil filter and oil cooler. Allison P-3 extended service coverage - 5 year unlimited miles shall be included. Transynd transmission fluid included. Fuel Tank: 60 gallon minimum capacity, slim line tank mounted on left side with minimum ground clearance of 23". Tank to be marked "Diesel Fuel". Electrical: 160 amp alternator, 12 volt starter, two (2) maintenance free batteries with total 1,900 CCA batteries. Lighting per D.O.T. specifications. To be L.E.D. type lights. Cab to have wiring and dash control for local installation of roof mounted lights. Halogen lights included. All electrical connections to be water proof. 6 position switch panel with a dedicated power distribution center and circuit breakers integral to trucks electrical system. Unit to have a 20 amp battery feed and ground wire along with 15 amp ignition feed, all three shall run to center of dash with approximately 2' of wire coiled up. 11 YES NO YES NO Frame: 120,000 PSI frame with 15" minimum reinforced YES NO integral frame extension for mounting of snow plow. C channel reinforcement full length of frame including front frame extension. Frame to have section models of 29 and RBM of 3,000,000 minimum. Cooling: Radiator to be severe duty largest capacity available. Radiator must YES NO be located to allow PTO shaft to pass under lower tank. Wheel Seals: Oil type; front and rear. YES / NO Steering: Dual hydraulic power. YES NO Heater & Air Heavy duty factory installed air conditioning unit, heater and YES / NO Conditioning: defroster, in accordance with manufacturer's specifications. Cab: Two -man all steel severe -service cab. Interior cab height, measured DESNO from floor to headliner must be a minimum of 54" to allow our entire staff of drivers the proper work area to perform their duties as expected. Bostrom air suspension high back driver's seat with arm rest, passenger seat to be fixed. Tilt hood. Cab entrance assist handles on each side of cab, 16" x 7" west coast and convex mirrors heated and remotely operated with breakaway mirror brackets, tinted windshield, intermittent windshield wipers and washer, dual sun visors, seat belts for both seats, tilt and telescopic steering column, and heavy duty door hinges. Electric locks and windows. AM/FM CD player. Cab to include hour meter, needle calibrated oil temperature gauge for transmission, water temperature, engine oil, volt meter, air pressure, and fuel gauges included. In addition, dual air horns with snow shields, interior dome light, and hand throttle. Cab to include cab mounted strobe light hooked into the Strobe system. Exhaust: Vertical, must not interfere with CA dimension or YES NO mounting of underbody. Vertical tail pipe guard and elbow included. 12 :.SHALL BE. AS TYPE DESCRIPTION......SPECIFIED (Circle One) Brakes: Anti -lock brake system to include 13 cubic ft. compressor YES I NO and Wabco style air dryer with spin on descant cartridge air dryer or equal, with heater. Dryer to be mounted with clearance for underbody equipment. Front brakes 16.5" x 6" with 20" brake chamber, rear brakes 16.5"x 7" with 30" brake chamber. Automatic slack adjusters, front and rear. Rear axle chambers to be mounted with clearance for paver to contact rear wheels. Dust shields on front and rear. Trailer air brakes with glad hands plus 7 way round pin plug at rear of truck. Truck shall also have electrical brake controller with Bargman T- way flat pin plug. Brake pedal to be mounted on firewall. Parts List: Vendor shall supply a complete list of part numbers of all filters YES NO including hydraulic, belts, and hoses along with fluid types and quantities. Rust Five year minimum, full repair warranty. Cab and chassis YES NO Proofing: to have Ziebart rust proofing and Rhino lining for under Dump bed. Safety: Truck and equipment to conform to all State and Federal YES NO Requirements, as well as O.S.H.A. and D.O.T. Back up Alarm to be included. Colors: Sewer Department — White Cab, Dark Green Dump Bed Dupont (YES / NO #474110B PFGS7 Manuals: Complete set for chassis, engine, electrical, transmission, all add on YES NO equipment. Can also be CD or DVD. Must include access to factory website for trouble shooting and parts lookup. Must include 1 year subscription for factory cab/chassis troubleshooting software. Training: Vendor to include up to eight hours of training for trouble shooting YES NO and parts software and website for Central Services employees. 13 in [,)y VV AJOni,,,,s SMALL RE AS TYPE DESCRIPTION SPECIFIED (Circle One) Specifications for 14'Ryfflp Body The intent of these specifications is to obtain a dumb body which meets the highest standards of the industry with respect to quality and strength of materials, design and workmanship, to the finished product. Bidder MUST be an authorized representative of the manufacturer and able to provide complete warranty service. uin�Mw"' Heavy Duty Note: Body builder must have a pre build conference with the (", YES , NO Dump Body: purchaser to go over layout and placement off all equipment and two such sessions during equipment installation. No equipment shall be installed without approved authorization from purchaser. BODY: These specifications shall describe a heavy-duty dump body, Ice and Snow control equipment to be used by the City of South Bend Water Department to maintain the streets. The equipment will consist of Dump Body, underbody scraper, and a load sense central hydraulics system, cable controlled with electronically controlled spreader. All construction shall meet or exceed industries standards. Welding shall comply with current AWS procedures. Alternate to these specifications shall be noted separately at the end of the proposal. NOTE: To insure a proper working body and one that will meet the city's needs, all placements of bed, bitch, lights, etc, shall be approved by the city before installation. Body shall be heavy duty 168" in length Inside width shall be 86". Note: there shall not be more than a two inch radius between the floor and side wall. The bodv shall be built to fit the Citv's existing leaf boxes. It will be the bidder's responsibility to, make sure body, will accommodate leaf box Sides and tailgate constructed of 3/16" Hardox 450 steel. No exceptions to type or grade. Floor constructed of 1/4" Hardox 450 steel one piece. No exceptions to type or grade. Tailgate shall be 48" in height., Front shall be 3/16" Hardox 450 No exceptions to type or grade. Formed steel long members shall be 14" thickness reinforced w / gussets. Understructure shall be crossmemberless, Lower body rub 14 77W, d iri [,)y VV A,Jm'ies rail shall be 5-1/2" wide 35 degree slope outward for dirt shedding. Grip strut walk bar shall be installed on both sides. Sides shall have vertical post box bracing. Top Rail shall be fully boxed Lower rub rail shall be material shedding. The body shall have a rear spreader apron 12" deep, Apron shall be pin on type and shall be able to interchange with tailgate spreader. There shall be (two per side) gussets to accept 2" x 8" side boards. Cabshield shall be 24" full width and be constructed of 3/16 450 Hardox. Rear Pillar shall have three (4) ovals cut -in by the body manufacturer for light placement. There shall be a fold down ladder located on the dump body mounted on the driver side front corner. Location shall be confirmed at time of installation with purchaser. There shall be a step type insert on the front driver's side on the inside of the body. Paint Body shall be painted to match the South Bend Water Works body color. Bidder shall check on final color with the Fleet Manager as to proper paint code. Final paint shall be a baked on automotive finish, Miscellaneous: 'There shall be installed a body prop, body up light, back up alarm. Body shall have 2 shovel brackets installed on the front of the body. Cab Shield: Cab protector shall be made from 8 gauge steel with 2" x 3" flat steel reinforcement. Y ( NO I ES, Tailgate: Tailgate shall be two formed panels will be single wall constructed YES �,)NO with 1/4"" Hardox 450 and shall be double acting. Tailgate chains shall be encased in chain mesh Two sets of cast banjo plates and chains long enough to hold tailgate in down position. Rear Pillar shall have sloped top. Minimum I" flame cut offset upper tailgate hinge. Minimum 1-1/2" upper tailgate pin. All welds shall be 100% continuous. Minimum 1- 1/4" lower tailgate pin incorporated in lower vertical tailgate brace Minimum 3/8" diameter proof coil spreader chains. Complete tailgate latching assembly reinforced with a 1/4" backing plate for added strength. Upper and lower banjo eyes in each rear corner post. Air operated tailgate latch mechanism. All tailgate pivots are grease zerk lubricated. Telescopic The hoist shall be of telescopic design and have a Trunion (YE NO Hoist: mounting. The hoist shall be double acting The hoist shall be designed to operate up to 2,500 PSI, and shall be self -bleeding. 15 The hoist shall have a V4" wall construction with bronze glands and pistons to assure a smooth and durable bearing surface. The glands shall each be a continuous cast bearing, SAE,660 bronze with a tensile strength of 44,000 PSI. The cylinder bead and piston shall be of a "ductile" continuously cast iron, with a tensile strength of 60,000 PSI. Each cylinder shall be internally seated. The inside seals shall be of a u-cup design made of nitrate packing. The cylinder shall have a Melonized/Q.P. running surface. The Melonized surfaces shall have a predominance of single—phase epsilon nitride. The nitride shall cover the entire cylinder surface. This shall give the cylinder superior wear and corrosion resistance and also shall have superior wear and fatigue properties. The cylinder rod shall be el 045/cl 050 steel with a tensile strength of 80,000 to 1000,000 pounds. The cylinder tubing shall be D.O.M. tubing, drawn over a mandrel, and shall have Tensile strength of 70,000 pounds. The tube shall have a surface harness of 80 Rockwell "B". The cylinder shall dismantle easily and overlap between stages for greater stability, The trunion collar shall be oscillation Each rod or pin eye shall have a grease zerk, The hoist shall have a two year warranty. Hoist shall incorporate a body prop, and body up light. Controls: There shall be two variable speed hydraulic controls mounted in the cab so that it may be operated as a spreader. One control will govern the conveyor speed; the other will control the spinner speed,. There shall also be a control valve located at the rear of the truck to allow an operator to start and stop the conveyor from the rear of the truck. Colors: Water Works - White Cab, Blue Dump Bed C64801,C-14 Alt. #1 ' Sewer Department — White Cab, Turquoise Tropic Green Dump Bed 97561A. Ladder: D-Rings: Tarp Rods: Tarp: A ladder will be provided for access to dump body. Bed shall have 3 D-Rings on each side of bed to mount leaf box, Tarp rods are to be provided on the body. "YES NO YES NO YE NO rm E NO Shall have a pull type tarp equal to what the City is currently using. . . .YE ...... ........ . .... NO LEO on by \IV Mounting of Dump Body Shall have a minimum of three (3) brackets (each side) - 2"x 4" flat iron minimum, at least one at rear, one in center, one at front. Shall be welded at rear and bolted with three (3) 5/8" bolts per bracket (minimum). Hoist cylinder shall be hooked to central hydraulics with 3/4" high pressure hose (two wire minimum). Floor of body to be approximately 54" off ground +/- 2". All welding to be done at factory on box. Other welding to be certified. Two rear hooks shall be supplied and bolted to rear of fi-ame. LED lights. Electrical: All lighting shall be LED, YES NO The wiring junction box is to be located on the right side of the body a minimum of 58" off the floor. The electrical box is to be completely sealed and waterproof All wiring to be continuous (without splices) and run inside of a waterproof harness. All connections are to be made inside waterproof junction boxes or within the structure of the body, Warning lights, strobes, and plow lights each to be run off OEM switches, Also included will be a pair of Track Lite LED Model #80880 or equal plow lights mounted to stainless steel brackets on hood. Plow lights to LED and integral to OEM headlights, Sealed lighting system shall be installed consisting of four (4) nylon tail/brake lights, two (2) on each side, and two (2) Whelen amber nylon alternating strobe flashing lights, one (1) on each side, mounted at top and two backup lights, one per side. The sealed lighting system shall be boxed into the rear corner posts, not to exceed a total box width of 99". All light wiring shall be in sealed tubing. All lights shall be standard 3 pin plug in style. There shall be a set of LED amber strobe lights mounted in weather protected boxes mounted under the cab shield facing forward. There shall be a second set of LED strobes mounted under the cab shield facing on both sides of body. Lights shall be installed in approved manor by the City. There shall also be an underbody plow light that will direct light on the underbody plow and a spreader light positioned at the left rear lower corner of the bed. Rear Pintle Wallace Forge 2044101, 50,000 lb or equal, mounted rear of truck, YES NO Hitch: center of hitch 25 1/2 " from. ground and center of track. 11 . Capacity: 6,000 Ibs. maximum vertical load qYES )NO 50,000 tbs. maximum gross trailer load Drawbar eye dimensions: 2" to 3" ID 1 1/4" to 1 5/8" diameter section. Note: Vendor will check with Central Services on exact location of hitch YE I NO and exact location of all rear mounted lights. WA F: A B d e d Dui VV A J () n e Minimum Specifications For A Close Center Load Hydraulic The hydraulic pump shall be US manufactured axial piston pressure YES NO -S Pump: and flow compensated load sensing type. The pump shall be cast iron construction and rated to 4,00 cubic inches per revolution at maximum stroke, The pump shall have a two inch suction line. The pump shall be rated for up to 3000 rpm and pressure. The pump shall have a 1 1/4" keyed drive shaft and SAE type C mounting flange. The pump, shall be model PAVC 65 Parker load sensing pump or equal. A I " steel ball valve shall be at the outlet of the pump. Hydraulic Pump The hydraulic pump will be a cast iron, variable displacement piston pump with load sensing control. Pump to feature internal bleed down compensator and separate adjustments for stand by and main pressure. Pump shall be Sauer Danfoss FRL series pump or prior approved equal. Pump capacity 90CC. Pump shall have a shutdown circuit. Circuit shall be energized by a tank mounted float to shut off pump flow in the event of a low oil condition, Shutdown system shall have a cab mounted system override switch. Mounting: The hydraulic pump shall be mounted with shaft centerline parallel ( YES) NO to the crankshaft centerline and at a level to create not more than a three degree angle on the drive line. The pump mounting shall be incorporated with a bracket fabricated to mount in the extended rails from the pump. Driveline: The hydraulic pump shall be driven directly off the engine (".'YES crankshaft via a splined driveline to, allow for movement. The ��NO driveline shall include grease fittings on both u-joints. Spicer. model 1310 series or equal. Reservoir: The hydraulic reservoir shall be of the slim line type and Y E NO shall be mounted between the chassis and the dump body, . .... . The mounting of the reservoir shall not extend the cab to axle dimension of the chassis, The hydraulic reservoir shall be 40-gallon capacity and be equipped with the following: Basket type filler breather cap, magnetic drain plug, 2" NPT suction with I 00-mesh screen type filter, separate return port for control drain line, sight temperature gauge externally mounted, internal baffling, heavy duty 1 1/4" ball type shut off valve shall be mounted on the suction side. 18 Hydraulic Lines All hydraulic lines, pipes, hoses, and fittings shall be of & Plumbing: sufficient capacity to accommodate the volume of oil without undue heating or turbulence in the system. A 2" suction line with a minimum SAE rating of 100-R4 must be used between the reservoir and the inlet of the pump. This suction hose shall be secured on both ends via heavy duty banding straps, radiator hose clamps -unacceptable. All of the pressure hoses, including the signal sensing line to the pump must have swivel fittings on BOTH ends and have a minimum SAE rating of 100-R2. Return lines and the case drain line must have a minimum SAE rating of 100-RI. All fittings shall be JIC. Push on clamp fittings are not acceptable. Hydraulic lines shall be routed to minimize interference with equipment and chassis components requiring periodic servicing. Appropriate support brackets, grommets, and tie wraps shall be provided to protect lines from abrasion, cutting and impact damage. Hoses shall not be installed near manifold or exhaust pipes so as to be affected by extreme heat. There shall be no pipe fitting used with any high pressure lines. Any and all hydraulic quick disconnect couplings used for spreader system and snow plow reversing system shall be of the bulkhead mounted style and be rigidly attached without the use of any hose clamp arrangements (loose hose ends are NOT acceptable), Couplers to be mounted to side of dump bed so they do not get covered with material or broken. Dust cap for male ends and dust plug for female ends must be attached to couplers. Maximum distance allowed between support clamps on all hydraulic hoses shall be approximately 24". Electronic The spreader control will utilize PWM technology to Manual control the variable feed and spread widths. The feed rate Spreader knob will accommodate 9 different settings while the Control: spread width knob will also accommodate 9 settings. The control head will have a power switch with an indicator lamp to provide status on the operation of the controller. Unit to be mounted for safe use by driver. Controller shall be Storm Guard Freedorn 2 controller. Spreader control shall have ability to be touch screen with usb data download. TEP wiring harness. Screw on cap and plug set for motor sensor connection. Detailed operators manual, 19 YES )NO YES')NO F i V k,) d au a I-)y W A J ir,,), �u Calibration manual. Wiring diagrams. Spreader Control Harness System: Spreader control and the hydraulic valve shall be connected via TIDE harness system, System will include a diagnostic board with direct reading LED circuit indication. Wiring system will exclude any infusion of direct application of 1000 PSI pressure wash spray. Connectors shall withstand 500 hours of 35C salt spray, The controller will also offer a combination "blast" - "unload" switch, This switch will allow the controller to produce a Blast function with programmable duration and a maintained unloads position for unloading the spreader or offering continuous operation during cleaning. The controller will allow the attachnient of speed pickup to start and stop the material spreading with vehicle motion. Wiring harness for the spreader control shall be full factory assembled with waterproof ends and covered in expanded nylon abrasion sleeve. A separate fuse shall be included into, the controller to protect it in the event of a short circuit deploying the inline fuse included in the installation. Controller shall be mounted in the cab with all hydraulic lines and valves outside: of the operator's compartment. All wiring that leaves the cab, such as valve supply and speed pickup, shall be secured with rubber covered steel clamps and include a watertight strain relief at the cab exit. Control Valve: The control valve shall be US manufactured, The valve is to be YES NO Greisen Model V40/V20 or equal load sensing stackable spool type with 0-ring ports mounted between the frame rails outside the vehicle cab. Hoist section and tool circuitry section to be V40 and all other sections to be V20. Valve sections to be arranged as follows: Hydraulic Valve: The hydraulic valve will be a cast iron, sectional type spool valve. Valve will feature individual section and flow compensation for each section. The valve will be rated for a nominal flow of 30 gpm. The load sensing shuttle network will be accessible without valve disassembly. Sections will be provided for following: 1. Hoist, double acting cylinder with down side work, port relief set as 500 psi. 2. Mid-inlet/transition section. 3. Underbody plow lift, double acting cylinder with down side 20 work port relief set at 500 psi. 4. Underbody plow angle, double acting cylinder with auxiliary cross port relief valve to protect cylinder. 5. Spinner attaclu-nent, dual compensated control. 6. Plow lift, double acting cylinder with down side work port relief set at 500 psi. 7. Valve Controls and Enclosure: The valve assembly shall be mounted in weather -tight enclosure. The valve enclosure shall be fabricated of 12-gauge steel, Enclosure shall be designed to not allow humidity to be trapped inside, Valve to be mounted with all ports coming out of the bottom and holes allowing for hose adaptor fitting. Enclosure will allow for bulkhead style cable to enter the fi,ont, Valve will be boxed in with cover and not the base. The cover shall be held to the enclosure by four heavy rubber latches. All plumbing shall be external, directly out the bottom of the valve enclosure. Specifications for Mounting Underbody Blade Assemblies It is the intent of these specifications to describe an adjustable YES ANC angled underbody scraper assembly. Note: In bidding this item, please include any cab controls or hydraulic modifications necessary. Each truck shall be equipped with a root model F-89 or equal underbody truck scraper. Hanger board shall be not less than 10" x 30 lbs, Structural channel reinforced by 1/2" x 8" plate and by 4" S & C 13.8# Channel the entire length of hinge line. Hinge shaft shall be not less than 2" OD high carbon steel. Moldboard shall be 10' long, I " x 20 " heat treated high carbon steel, offset for USS punched blades. Circles shall be constructed of heavy duty I " thick solid steel. One (1) piece design (no casting) with four (4) independent heavy duty mounting legs of 4" S & C channel 13.8# per foot. Moldboard shall be cushioned by two (2) heavy duty cushion spring shock absorber assemblies. Scrapers shall have dual cylinders. Power reverse with two (2) 4" double acting cylinders with chrome plated rods. Cylinder rods clevis bosses to be 2" OD carbon steel, solid welded to the top and bottom of the hanger board. Scraping angle should not be less than 45 degrees adjustable as desired. All moving parts shall be zerk equipped. Power shall be provided from central hydraulic system, W RU 4'� by W A Moldboard to be actuated by two (2) 4" double acting cylinders mounted horizontally on the scraper by 3/4" thick reinforced steel trunnion brackets. Trunnion bearings shall be 2" OD x 1 1/4" carbon steel. Blade down pressure shall be adjustable and with no less than 1,500 lbs. maximum to be set at 600 PSI. All fittings to be JIC. Push on fittings shall not be accepted. Underbody scrapers shall be furnished with 8" x 3/4 standard carbon flame hardened blades. Moldboard shall have replaceable blade and end bits. Power reverse shall be cab controlled. Underbody grease zerts shall be centrally located. Specifications for Snow Plow Quick Hitch Large General. Snow plow quick hitch shall be heavy duty type to be used for street and/or highway snow plowing by heavy duty trucks. Hitch shall be designed to permit adequate lift and full radius swing of hydraulic controlled power reversing snow plows. Type: Snow plow hitch shall be an automatic snap coupling type, 34" wide, equipped with 3" diameter by 10" stroke hydraulic lift cylinder. Automatic locking shall be accomplished by dual cam actuated spring loaded locking lugs, A lever shall be provided for retraction of looking lugs. Looking lugs shall be I - 7/8" minimum diameter with roller bearings to aid in lifting and lowering plow. Construction; Truck Half. The truck half of the automatic snap coupling hitch shall be 34" wide, 42" high and shall be fabricated from 3/8" thick structural steel, adequately cross membered and securely mounted on the trucks extended ftont frame. Bottom support members shall be securely attached to the main frame of truck chassis at approximately the center of the front axle. Anti -thrust plating shall be incorporated to prevent transverse movement of hitch and rearward thrust against triangulating bottom support members. Stabilizer bars shall be connected between top portion of the hitch and main frame of the truck.All fasteners shall be of the high tensile type. A lift arm and base support for the hydraulic cylinder shall be included. Lift arm to be one solid piece of 3/4" material with one piece 2 1/2" x 3 1/4" long cold rolled round welded on the lift arias 22 1: ii � �ed o r� by VV A , l on es, at lift point. Top brace to be 3/8" x 2" x 2". Bottom brace to be 2" x 3" x 3". Rear vertical brace to be 3/8" x 2 1/2" x 2 1/2"', goo '4 Color: Water Works - White Cab, Blue Dump Bed C6480KH Alt. #1. YES Sewer Department— White Cab, Turquoise Tropic Green Dump Bed 97561 A. Quantity: One (1) or more YES/NO Trade -In: Unit SN464, 2000 Freightliner Dump 'Truck, VIN#IFVXJFBBIYHO10099 Alternate 4 1: Quick Hitch for Front Plow Truck frarne will be extended forward of grill. Bidder will furnish minimum 2"x 4"' x 8" x 48"' long angle across front bumper.. Bottom braces shall be installed from hitch to frame with 3 1/4 bolts, grade 8. Material I " x 4" flat iron minimum. Top braces 2"x 4" flat iron minimum and run to frame. Hose to hook up hitch and cylinder shall be 3/8" and furnished by bidder. Hooked to hydraulics part with 1,000 lbs, PSI port relief minimum. Bumper angle is to be mounted to fi-ame with four (4) pieces of 4" x 8" minimum angle to frame. Hood to have cable stop before resting on plow hitch. Plow lights to be included. Truck frame will be extended forward of grill. Bidder will furnish minimum 2"x 4" x 8" x 48" long angle across front bumper. Bottom braces shall be installed from hitch to frame with 3 3/4" bolts, grade 8. Material I " x 4" flat iron minimum. Top braces 2"x 4" flat iron minimum and run to fi-ame. Hose to hook up hitch and cylinder shall be 3/8" and furnished by bidder. Hooked to hydraulics part with 1,00�0 lbs. PSI port relief minimum. Bumper angle is to be mounted to frame with four (4) pieces of 4" x 8" minimum angle to frame, Hood to have cable stop before resting on plow hitch. Plow lights to be included. Alternates #2: Front Snow Plow s YES/11C Moldboard length ill Height 4311 Width of cut ill 28 deg. 011 35 deg. 91011 42 deg 812" 23 F1He(,'J udi [-,,ay W A,Jo raes Moldboard deflector - Built-in Left hand discharge ear Right hand discharge ear Cutting edge - 2"x 6 with US Highway Blade Punching Lift 1011 Trip Spring 2 Canon Style Rebound Standard Hinge Points, & Size 4-1 Outside Hinge Spread 8511 Size Semicircle Angle 3 1/2" x 3 1/2" x 2 Moldboard Bottom Angle 411 x 4" x 3/4" Top Moldboard Stiffener 3" x 3" x 3/8" Hitch Complete - Hustin Style 34" Quick Hitch Snow Wheels Brand Shoes - 2 with Full Height Adjustment Curb Guards - Left and Right Hand Replaceable Alternate #3: CNG Fuel System- 320 horsepower, with 1,000 ft. lbs, torque minimum Cummins Westport ISL G320 natural gas engine. Emergency shutdown system for low oil pressure, high water temperature. Air filter shall be replaceable paper type with a restriction gauge. Oil filter to be a combination full flow/bypass type. Fuel system to include a low pressure coalescing fuel filter. 1,500 watt block heater, with thermostat, to be included. Engine warranty to be a minimum of 5 years/200,000 miles/1 0,000 hours. Engine troubleshooting manuals/software to be included. Fuel tank capacity 75 DGE. Alternate #4: Stainless, Steel Monroe tailgate spreader Model #MS966 Price Guarantee: The successful bidder shall guarantee the bid price for a minimum of 12 months ftom the bid award date to the City of South Bend, The City reserves the right to purchase up to three (3) additional units at this price. Warranty: Chassis,: 12 months/12,000 miles complete. Body, hoist, underbody - 12 months from date of delivery. Engine and transmission as specified. The unit shall be awarded as a complete dump truck with snow equipment, The successful bidder shall be responsible for all warranty repairs. The successffil bidder shall provide written certification of all extended warranties at the time of delivery. It is, the objective of Equipment Services to keep this equipment available for service on a 24 hour basis, especially during the winter season. Therefore, repairs that may require lengthy travel time and distance may 24 YES/0 0 YE NO F Med iui by V/ A Joi"w affect this bid. It will be at the discretion of Equipment Services as to the location at which the warranty work will be performed. A. Your service man at our shop. E. Your service man at your shop. Note: If the work is to be performed at your shop and your shop is located outside of the City limits,, you will be responsible for pick-up, and delivery of the unit, within eight (8) hours of notification or you will be assessed $ 100.00. Pre -Construction: Vendor will have pre construction meeting at Central Services. Nk, BID NAME Spec AF — One (1) or More 2017 or Newer Tandem Axle Dump Truck FOR IBiDS DUE December 12, 2017 at 9,30 a.m.. Description Year/Make/Mandell Unit Price Complete Unit Sid 2019 Freightliner Model 114SD with equipment by W.A. Janes Truck Bodies & Equipment li $ 151,167.010 Year Make/Model — "Trade In Unit Price 2000 Unit SN464, Freightliner Dump Truck, VIN# l FVXJ B B I YHG10099, (5,000.00) Alternate# Description Cost Total I Quick Hitch for Font Plow $ 4,398.00 $ 4,398.00 2 Front Snow Plow $ 9,478.00 $ 9,478,00 3 LNG Fuel System $ 43,220.00 $ 43,220.00 4 Stainless Steel Monroe Tailgate reader: Model #MS966 $ 3,982.00 $ 3,982.00 Estimated number of days for delivery from award 180-210 days date, Bidder (Firm): Ciity/State/Zips Telephone Number: Truck Centers, Inc. d/b/a Hill Truck Sales 1011 W. Sample St. South Bend, IN 46619 574-289-4065 Fax Number: 574-289-1497 By Signature). µ~ (Printed' Name) 26 (Title) BOARD OF PUBLIC WORKS Gary A. Gilot, President Suzanna M. Fritzberg, Member James A. Mueller, Member Elizabeth A. Maradik, Member Therese J. Dorau, Member Attest: Linda M. Martin, Clerk 27 Document A31 OTM-2010 f 04 V I 01r, re 1 CONTRACTOR: (Nance, legal stakes and address) SURETY: This document has important (Marne, legal slaws and priwipal place ofbushwss) legal consequences. TRUCK CENTERS, INC., Travelers Casualty And Surety Company Of Consultation with an 2280 Formosa Road America attorney is encouraged with Troy, IL 62294 One Tower Square respect to its completion or Hartford, CT 06183 modification. OWNER: Mail Notices To: Any singular reference to Contractor, Surety, Owner, (Nance, legal status and address) Travelers Attn: Surety Claim Dept. or other party shall be C Of South Bend/Board Of Public Works City One Tower Square 2S1 A considered plural where County City Building Room 1316 Hartford, CT 06183 applicable. 227 W� Jefferson Street South Bend, IN 46601 BOND AMOUNT- Ten Percent of the Amount Bid .................. dollars ($ 10% of Amount Bid) PROJECT: 2017 or Newer Tandem Axle, Dump Truck (Maine, location or address, and Project number, if airy) The Contractor and Surety are bound to the Owner in the amount set forth above, for the payment of which the Contractor and Surety bind themselves, their heirs, executors, administrators, successors and assigns, jointly and severally,, as provided herein. The conditions of this Bond are such that if the Owner accepts the bid of the Contractor within the time specified in the bid documents, or within such time period as may be agreed to by the Owner and Contractor, and the Contractor either (1) enters into a contract with the Owner in accordance with the terms of such bid, and gives such bond or bonds as may be specified in the bidding or Contract Documents, with a surety admitted in the jurisdiction of the Project and otherwise acceptable to the Owner, for the faithful performance of such Contract and for the prompt payment of labor and material furnished in the prosecution thereof, or (2) pays to the Owner the difference, not to exceed the amount of this Bond, between the amount specified in said bid and such larger arnount for which the Owner may in good faith contract with another party to perform the work covered by said bid, then this obligation shall be null and void, otherwise to remain in full force and effect. The Surety hereby waives any notice of an agreement between the Owner and Contractor to extend the time in which the Owner may accept the bid. Waiver of notice by the Surety shall not apply to any extension exceeding sixty (60) days in the aggregate beyond the time for acceptance of bids specified in the bid documents, and the Owner and Contractor shall obtain the Surety's consent for an extension beyond sixty (60) days. If this Bond is issued in connection with a subcontractor's bid to a Contractor, the term Contractor in this Bond shall be deemed to be Subcontractor and the term Owner shall be deemed to be Contractor. When this Bond has been furnished to comply with a statutory or other legal requirement in the location of the Project, any provision in this Bond conflicting with said statutory or legal requirement shall be deemed deleted berefrom and provisions conforming to such statutory or other legal requirement shall be deemed incorporated herein. When so furnished, the intent is that this Bond shall be construed as a statutory bond and not as a common law bond. Signed and sealed this 12th day of December, 2017. (witnelss) d- Witness) Donna Robson, Wince TRUCK CENTERS, INC. (Principal) (Seal) lr-' r av-c N Travelers Casualtv AV Company Of America (Su lt Ar) (Seat) (Title) Andrew P. Thorne, Attorney -In -Fact Init. AIA Document A3 10TM— 2010, Copyright 01963, 1970 and 2010 by The American Institute of Architects. All rights reserved. WARNING: This AIA DOCU ni ent is protected by U.S. Copyright Law and International Treaties, Llnauthmized reproduction or distribution of this AIA Document. or any portion of it, may result in severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. Purchasers are permitted to reproduce Len (10) copies of this document when completed. To report copyright violations of AIA Contract Documents, e-mail The Annerican Institute of Architects' legal counsel, copyrighLOala.org, 061110 State of Missouri County of St. Louis On 12/12/2017, before me, a Notary Public in and for said County and State, residing therein, duly commissioned and sworn, personally appeared Andrew P. Thome known to me to be Attorney -in -Fact of TAMITME. the corporation described in and that executed the within and foregoing instrument, and known to me to be the person who executed the said instrument in behalf of said corporation, and he duly acknowledged to me that such corporation executed the same. IN WITNESS WHEREOF, I have hereunto set my hand and affixed my official seal, the day and year stated in this certificate above. Donna Robson, Notary Public DONNA ROBSON Notary PuNic — Notary Seal st,ite of missouri, St. Chm-les COLOW commission it 171,67942 My Commission Expires: My Commission Expires June 21, 2021 TRAVELERS i POWER OF ATTORNEY Travelers Casualty and Surety Company of America Travelers Casualty and Surety Company St. Paul Fire and Marine Insurance Company Attorney -In -Fact No, 231637 KNOW ALL MEN BY THESE PRESENTS: That Travelers Casualty and Surety Company of America, Travelers Casualty and Surety Company, and St. Paul Fire and Marine Insurance Company are corporations duly organized under the laws of the State of Connecticut (herein collectively called the "Companies"), and that the Companies do hereby make, constitute and appoint Andrew P Thorne, of the City of Chesterfield, State of Missouri, their true and lawful Attorney -in -Fact to sign, execute, seal and acknowledge any and all bonds, recognizances, conditional undertakings and other writings obligatory in the nature thereof on behalf of the Companies in their business of guaranteeing the fidelity of persons, guaranteeing the performance of contracts and executing or guaranteeing bonds and undertakings required or permitted in any actions or proceedings allowed by law. IN WITNESS WHEREOF, the Companies have caused this instrument to be signed and their corporate seals to be hereto affixed, this 3rd day of February, 2017. Travelers Casualty and Surety Company of America Travelers Casualty and Surety Company St. Paul Fire and Marine Insurance Company State of Connecticut City of Hartford ss. Robert L. Raney, Senior Vice President On this the 3rd day of February, 2017, before me personally appeared Robert L. Raney, who acknowledged himself to be the Senior Vice President of Travelers Casualty and Surety Company of America, Travelers Casualty and Surety Company, and St, Paul Fire and Marine Insurance Company, and that he, as such, being authorized so to do, executed the foregoing instrument for the purposes therein contained by signing on behalf of the corporations by himself as a duly authorized officer. In Witness Whereof, I hereunto set my hand and official seal. My Commission expires the 30th day of June, 2021 0�„TE7 * AUEUO * Mar'ie C. Tetreault, Notary Public This Power of Attorney is granted under and by the authority of the following resolutions adopted by the Boards of Directors of Travelers Casualty and Surety Company of America, Travelers Casualty and Surety Company, and St. Paul Fire and Marine Insurance Company, which resolutions are now in full force and effect, reading as follows: RESOLVED, that the Chairman, the President, any Vice Chairman, any Executive Vice President, any Senior Vice President, any Vice President, any Second Vice President, the Treasurer, any Assistant Treasurer, the Corporate Secretary or any Assistant Secretary may appoint Attorneys -in -Fact and Agents to act for and on behalf of the Company and may give such appointee such authority as his or her certificate of authority may prescribe to sign with the Company's name and seal with the Company's seal bonds, recognizances, contracts of indemnity, and other writings obligatory in the nature of a bond, recognizance, or conditional undertaking, and any of said officers or the Board of Directors at any time may remove any such appointee and revoke the power given him or her; and it is FURTHER RESOLVED, that the Chairman, the President, any Vice Chairman, any Executive Vice President, any Senior Vice President or any Vice President may delegate all or any part of the foregoing authority to one or more officers or employees of this Company, provided that each such delegation is in writing and a copy thereof is filed in the office of the Secretary; and it is FURTHER RESOLVED, that any bond, recognizance, contract of indemnity, or writing obligatory in the nature of a bond, recognizance, or conditional undertaking shall be valid and binding upon the Company when (a) signed by the President, any Vice Chairman, any Executive Vice President, any Senior Vice President or any Vice President, any Second Vice President, the Treasurer, any Assistant Treasurer, the Corporate Secretary or any Assistant Secretary and duly attested and sealed with the Company's seal by a Secretary or Assistant Secretary; or (b) duly executed (under seal, if required) by one or more Attorneys -in -Fact and Agents pursuant to the power prescribed in his or her certificate or their certificates of authority or by one or more Company officers pursuant to a written delegation of authority; and it is FURTHER RESOLVED, that the signature of each of the following officers: President, any Executive Vice President, any Senior Vice President, any Vice President, any Assistant Vice President, any Secretary, any Assistant Secretary, and the seal of the Company may be affixed by facsimile to any Power of Attorney or to any certificate relating thereto appointing Resident Vice Presidents, Resident Assistant Secretaries or Attorneys -in -Fact for purposes only of executing and attesting bonds and undertakings and other writings obligatory in the nature thereof, and any such Power of Attorney or certificate bearing such facsimile signature or facsimile seal shall be valid and binding upon the Company and any such power so executed and certified by such facsimile signature and facsimile seal shall be valid and binding on the Company in the future with respect to any bond or understanding to which it is attached. I, Kevin E. Hughes, the undersigned, Assistant Secretary of Travelers Casualty and Surety Company of America, Travelers Casualty and Surety Company, and St. Paul Fire and Marine Insurance Company, do hereby certify that the above and foregoing is a true and correct copy of the Power of Attorney executed by said Companies, which will remain in full force and effect through December 31, 2018. Kevin E. Hughes, Assistant Secretary 12 December 2017 Dated this day of Ge D To verify the authenticity of this Power of Attorney, call I-800-421-3880 to contact us. Please refer to the Attorney -In -Fact number, the above -named individual and the details of the bond to which the power is attached. Prepared for: Prepared by: Board of Public Works Rich Stopczynski City of South Bend IN Truck Centers, Inc. County City Bldg. 10111 W, Sampde St. South (Bend, IN 46601 South Bernd, IN 46619 Phone: 574-289-4065 rstopczynski@truckcenterslnc.com Description 114SD CONVENTIONAL CHASSIS 2019 MODEL YEAR SPECIFIED SET BACK AXLE - TRUCK TRAILER TOWING PROVISION AT END OF FRAME FOR TRUCK LHI PRIMARY STEERING LOCATION / TRUCK/TRAILER CONFIGURATION DOMICILED, USA (EXCLUDING CALIFORNIA AND CARB OPT -IN STATES) UTILITY/REPAIR/MAINTENANCE SERVICE GOVERNMENT BUSINESS SEGMENT DIRT/SAND/ROCK COMMODITY TERRAIN/DUTY: 100% (ALL) OF THE TIME, IN TRANSIT, IS SPENT ON PAVED ROADS MAXIMUM 8% EXPECTED GRADE ROUGH, MAINTAINED, CONCRETE OR ASPHALT PAVEMENT- MOST SEVERE IN -TRANSIT (BETWEEN SITES) ROAD SURFACE FREIGHTLINER SID VOCATIONAL WARRANTY EXPECTED FRONT AXLE RATING: 20,000 lbs. EXPECTED REAR AXLE RATING: 46,000 lbs. GROSS VEHICLE WEIGHT RATING: 66,000 lb& i i / / / SNOWPLOW, SALT SPREADER AND BELLY PLOW BODY WITH HIGH GROUND CLEARANCE EXPECTED TRUCK BODY LENGTH: 14.O ft, EXPECTED TRUCK BODY WIDTH: 96.0 in WA JONES TRUCK EQUIPMENT SB121217A - Tandem Diesel Dump bid Page 1 of 13 Prepared for, Board of Public Works City of South Bend IN! County City Bldg South Bend, IN 46601 Prepared by: Rich Stopczynski Truck Centers, Inc. 1011 W. Sample St. South (Bend, IN 46619 Phone: 574-289-4065 rstopozynskii@tru:ckcentersinc.com Description / r EQUIPMENT TRAILER SINGLE (1) TRAILER CUMMINS L9 300 HP @ 2000 RPM, 2200 GOV RPM, 860 LBIFT TORQUE o@ 1300 RPM r / / / 65 MPH ROAD SPEED (LIMIT CRUISE CONTROL SPEED LIMIT SAME AS ROAD SPEED LIMIT 2016 ONBOARD IDIAGNOSTICSI2010 EPA/CARBIFINAL GHG17 CONFIGURATION STANDARD OIL PAN ENGINE MOUNTED OIL CHECK AND FILL SIDE OF HOOD AIR INTAKE WITH FIREALL MOUNTED DONALDSON AIR CLEANER WITH SAFETY ELEMENT AND INSIDEIOUTSIDE AIR WITH SNOW DOOR DR 12V 160 AMP 36-St BRUSHLESS QUADRAMOUNT PAD ALTERNATOR WITH REMOTE BATTERY VOLT SENSE (2) ALLIANCE MODEL 1231, GROUP 31,12 VOLT MAINiTENANCE FREE 2250 CCA THREADED STUD BATTERIES BATTERY BOX WITH ALUMINUM COVER MOUNTED SHORT SIDE TO RAIL STANDARD BATTERY JUMPERS LH BATTERY BOX MOUNTED AS FAR AFT AS POSSIBLE, NO GREATER THAN 60 INCHES BACK OF CAB WIRE GROUND RETURN FOR BATTERY CABLES WITH ADDITIONAL FRAME GROUND RETURN NON -POLISHED BATTERY BOX COVER CUMMINS TURBOCHARGED 18.7 CFM AIR COMPRESSOR WITH INTERNAL SAFETY VALVE ELECTRONIC ENGINE INTEGRAL SHUTDOWN PROTECTION SYSTEM RAISED RH OUTBOARD UNDER STEP MOUNTED HORIZONTAL AFTEIRTREATMENT SYSTEM ASSEMBLY WITH RH B-PILLAR MOUNTED VERTICAL TAILPIPE SB121217A - Tandem Diesel Dump bid Page 2 of 13 Prepared for: Board of Public Works City of South Bend IN County City Bldg, South Bend, IN 46601 Description ENGINE AFTERTREATMENT DEVICE, AUTOMATIC OVER THE ROAD REGENERATION AND DASH MOUNTED REGENERATION REQUEST SWITCH 10 FOOT 00 INCH (120 INCH+OI-5.9 INCH) EXHAUST SYSTEM HEIGHT RH CURVED VERTICAL TAILPIPE B-PILLAR RAISED UNDER STEP MOUNTED AFTERTREATMENT SYSTEM 6 GALLON DIESEL EXHAUST FLUID TANK 100 PERCENT DIESEL EXHAUST FLUID FILL DIESEL EXHAUST FLUID PUMP MOUNTED AFT OF DIESEL EXHAUST FLUID TANK LH MEDIUM DUTY STANDARD DIESEL EXHAUST FLUID TANK LOCATION STANDARD DIESEL EXHAUST FLUID TANK CAP STAINLESS STEEL AFTERTREATMENT DEVICEIMUFFLERITAILPIPE SHIELD HORTON DRIVEMASTER ADVANTAGE ONIOFF FAN DRIVE AUTOMATIC FAN CONTROL WITH DASH SWITCH AND INDICATOR LIGHT, NON ENGINE MOUNTED CUMMINS SPIN ON FUEL FILTER COMBINATION FULL FLOW/BYPASS OIL FILTER 1300 SQUARE INCH ALUMINUM RADIATOR ANTIFREEZE TO -34F, OAT (NITRITE AND SILICATE FREE) EXTENDED LIFE COOLANT GATES BLUE STRIPE COOLANT HOSES OR EQUIVALENT CONSTANT TENSION HOSE CLAMPS FOR COOLANT HOSES RADIATOR DRAIN VALVE 1350 ADAPTER FLANGE FOR FRONT PTO PROVISION PHILLIPS-TEMRO 1000 WATT/115 VOLT BLOCK HEATER CHROME ENGINE HEATER RECEPTACLE MOUNTED UNDER LH DOOR ELECTRIC GRID AIR INTAKE WARMER DELCO 12V 38MT HD STARTER WITH INTEGRATED MAGNETIC SWITCH Prepared by: Rich Stopczynski Truck Centers, Inc. 1011 W. Sample St. South Bend, IN 46619 Phone: 574-289-4065 rstopczynski@truckcentersinc.com SB121217A - Tandem Diesel Dump bid Page 3 of 13 Prepared for: Board of Public Works City of South Bend IN County City Bldg. South Bend, IN 46601 Description ALLISON 3500 RIDS AUTOMATIC TRANSMISSION WITH PTO PROVISION VEHICLE INTERFACE WIRING CONNECTOR WITH PDM AND BLUNT CUTS, INSIDE CAB ELECTRONIC TR'ANSMISSIlON CUSTOMER ACCESS CONNECTOR FIREWALL MOUNTED MAGNETIIC PLUGS, ENGIINE DRAIN, TRANSMISSION DRAIN, AXLE(S) FALL AND DRAIN PUSH BUTTON ELECTRONIC SHIFT CONTROL, DASH MOUNTED TRANSMISSION PROGNOSTICS - ENABLED 2013 WATER TO OIL TRANSMISSION COOLER, IN RADIATOR END TANK TRANSMISSION OIL CHECK AND FILL WITH ELECTRONIC OIL LEVEL CHECK SYNTHETIC TRANSMISSION FLUID (TES-295 COMPLIANT) DETROIT DA-F-20.0-5 20,000# FIL1 71.0 KPI/3.74 DROP SINGLE FRONT AXLE MERITOR 16.5X6 Q+ CAST SPIDER CAM FRONT BRAKES, DOUBLE ANCHOR, FABRICATED SHOES NON -ASBESTOS FRONT (BRAKE LINING CONMET CAST IRON FRONT BRAKE DRUMS FRONT BRAKE DUST SHIELD'S FRONT OIL SEALS VENTED FRONT HUB CAIPS WITH WINDOW, CENTER AND SIDE PLUGS - OIL STANDARD SPINDLE NUTS FOR ALL AXLES HALDEX AUTOMATIC FRONT SLACK ADJUSTERS STANDARD KING PIN BUSHINGS TRW THP-0 POWER STEERING WITH RCH45 AUXILIARY GEAR POWER STEERING PUMP 4 QUART POWER STEERING RESERVOIR OIL/AI,R POWER STEERING COOLER ORGANIC SAE 80/90 FRONT AXLE ILUBE Prepared) by: Rich Stopozynski Truck Centers, Inc. 1011 W. Sample St. South. Bend, IN 46619 Phone: 574-289-4065 rstopczynski@truckcentersinic.com SB121217A - Tandem Diesel Dump bM Page 4 of 13 Prepared for Board of Public Works City of South Bend IN County City Bldg, South Bend, IN 46601 Description 20,000# FLAT LEAF FRONT SUSPENSION GRAPHITE BRONZE BUSHINGS WITH SEALS - FRONT SUSPENSION FRONT SHOCK ABSORBERS RT-46-160 46,000# R-SERIES TANDEM REAR AXLE, 6.14 (REAR AXLE RATIO IRON REAR AXLE CARRIER WITH STANDARD AXLE HOUSING MXL 17T MIERITOR EXTENDED LURE MAIN DRIVELINE WITH HALF ROUND YOKES MXL 17T MEIRITOR EXTENDED LU'BE INTERAXLE DRIVELINE WITH HALF ROUND YOKES (1) INTERAXLE LOCK VALVE FOR TANDEM OR TRIDEM DRIVE AXLES BLINKING LAMP WITH EACH INTERAXLE LOCK SWITCH, INTERAXLE UNLOCK DEFAULT WITH IGNITION OFF MERITOR 16.5X Q+ CAST SPIDER CAM REAR BRAKES, DOUBLE ANCHOR, FABRICATED SHOES NON -ASBESTOS REAR BRAKE LINING ASPHALT SPREADER CLEARANCE REAR BRAKE GEOMETRY CONMET CAST IRON REAR BRAKE DRUMS REAR BRAKE DUST SHIELDS REAR OIL SEALS BENDIX EVER SURE LONGSTROKE 2-DRIVE AXLES SPRING PARKING CHAMBERS HALDEX AUTOMATIC REAR SLACK ADJUSTERS ORGANIC SAE 80/90 REAR AXLE LURE STANDARD REAR AXLE BREATHER(S) HENIDRICKSON HN462 @a 46,000# REAR SUSPENSION HENDRICKSON HIN 400/460 - 9.56 INCH RIDE HEIGHT STANDARD AXLE SEATS IN AXLE CLAMP GROUP 52 INCH AXLE SPACING Prepared by: Rich Stopczynski Truck Centers., Inc. 1011 W. Sample St. South Bend, IN 46619 Phone: 574-289-4065 rstopczynski c@truckcentersinc.com SB121217A - Tandem Diesel Dump bid Page 5 of 13 Prepared for: Board of Public Works City of South Bend IN County City Bldg, South Bend, IN 46601 Prepared by: Rich Stopozynski Truck Centers, Inc. 1011 W. Sample St. South Bend, IN 46619 Phone: 574-2894065 rstopczynski@truckoentersino.com Description HENDRICKSON HN, HAULMAAX AND UILTIMAAX SERIES STEEL BEAMS WITH BAR PIN FORE/AFT AND TRANSVERSE CONTROL RODS REAR SHOCK ABSORBERS - TWO AXLES (TANDEM) 1/111004#01r I WABCO 4S14M ABS WITHOUT TRACTION CONTROL REINFORCED NYLON, FABRIC BRAID AND WIRE BRAID CHASSIS AIR LINES FIBER BRAID PARKING BRAKE HOSE STANDARD BRAKE SYSTEM VALVES STANDARD AIR SYSTEM PRESSURE PROTECTION SYSTEM STD, U.S. FRONT BRAKE VALVE RELAY VALVE WITH 5-8 PSI CRACK PRESSURE, NO REAR PROPORTIONING VALVE WABCO SS-1200 PLUS AIR DRYER WITH INTEGRAL AIR GOVERNOR AND HEATER WABCO OIL COALESCING FILTER FOR AIR DRYER AIR DRYER MOUNTED OUTBOARD ON RH RAIL STEEL AIR TANKS MOUNTED FOR MAX GROUND CLEARANCE PULL CABLE ON WET TANK, PETCOCK DRAIN VALVES ON ALL OTHER AIR TANKS YEMEN AIR CONNECTIONS TO END OF FRAME WITH GLAD HANDS FOR TRUCK AND DUST COVERS PRIMARY RECEPTACLE CENTER PIN WIRED TO BACKUP LIGHT CIRCUIT WITH STOP SIGNAL PREWI RE PACKAGE SAE J560 7-WAY PRIMARY TRAILER CABLE RECEPTACLE MOUNTED END OF FRAME UPGRADED CHASSIS MULTIPLEXING UNIT SUPPLEMENTAL J560 7-WAY RECEPTACLE LOCATED WITH PRIMARY RECEPTACLE 11111110/11/so 4800MM (189 INCH) WHEELBASE 7/16X3-9/16X11-1/8 INCH STEEL FRAME (11.1 11MMX282.6MM/0.437Xl 1.13 INCH) 120K PSI 1/4 INCH (6.35MM) C-CHANNEL INNER FRAME REINFORCEMENT (31,0 SECTION MODULUS AND 3,715,000 RBM RATINGS) SB121217A - Tandem Diesel Dump, bid Page 6 of 13 Prepared for: Board of Public Works City of South Bend IN County City Bldg. South Bend, IN 46601 Prepared by: Rich Stopczynski Truck Centers, Inc. 1011 W. Sample St. South Bend, IN 46619 Phone: 574-289-4065 rstopczynskitruckcentersinc.com Description 1600MIW (63 INCH) REAR FRAME OVERHANG 24 INCH INTEGRAL FRONT FRAME EXTENSION WITH 0.25 INCH INSERT CALCULATED EFFECTIVE BACK OF CAB TO REAR SUSPENSION CIL (CA) : 120.45 in SQUARE END OF FRAME FRONT CLOSING CROSSMEMBER STANDARD WEIGHT ENGINE CROSSMEMBER STANDARD MIDSHIP #1 CROSSMEMBER(S) REARMOST CROSSMEMBER MOUNTED WITH LAST CROSSMEMBER 13 INCHES FROM END OF FRAME HEAVY DUTY SUSPENSION CROSSMEMBER 14 INCH PAINTED STEEL SEVERE DUTY BUMPER BUMPER MOUNTING FOR SINGLE LICENSE PLATE HUCK-'SPIN ROUND COLLAR CHASSIS FASTENERS SUSPENSION'S ONLY 60 GALLON1227 LITER RECTANGULAR ALUMINUM FUEL TANK - LHI RECTANGULAR FUEL TANK PLAIN ALUMINUM FUEL TANK WITH PAINTED BANDS FUEL TANK FORWARD - RAISED MOUNTING PLAIN STEP (FINISH FUEL TANK CAP DETROIT FUELMATER SEPARATOR WITH WATER IN FUEL SENSOR, HAND PRIMER AND 12 VOLT PREHEATER EQUIFILO INBOARD FUEL SYSTEM HIGH TEMPERATURE REINFORCED NYLON FUEL LINE INSULATION FOR FUEL LINES i MICHELIN XZU-S2 315180R22.5 20 PLY RADIAL FRONT TIRES MICHELIN X WORKS XDY 11 R22.5 16 PLY RADIAL REAR TIRES SB'121217A - Tandem Diesel Dump bid Page 7 of 13 Prepared for: Board of Public Works City of South Bend IN County City Bldg. South Bend, IN 46601 Description CONIMET PRESET PLUS PREMIUM IRON FRONT HUBS CONMET PRESET PLUS PREMIUM IRON REAR HUBS ACCURIDE 29039 22.5X9.00 10-HUB PILOT 5.25 INSET 5-HAND STEEL DISC FRONT WHEELS ACCURIDE 28828 22.5X8.25 10-HUB PILOT 2- HAND HD STEEL DISC REAR WHEELS 114 INCH BBC FLAT ROOF ALUMINUM CONVENTIONAL CAB AIR CAB MOUNTING NIONREMOVABLE BUGSCREEN MOUNTED BEHIND GRILLE SHORT FENDER WITH MUDFLAP BOLT -ON MOLDED FLEXIBLE FENDER EXTENSIONS LH AND RH GRAB HANDLES BRIGHT FINISH RADIATOR SHEILLIHOOD BEZEL STATIONARY BLACK GRILLE WITH BRIGHT ACCENTS CHROME HOOD MOUNTED AIR INTAKE GRILLE FIBERGLASS HOOD DUAL 14 INCH ROUND POLISHED AIR HORNS DUAL ELECTRIC HORNS DUAL HORN SHIELDS DOOR LOCKS AND IGNITION SWITCH KEYED THE SAME HALOGEN COMPOSITE HEADLAMPS WITH BRIGHT BEZELS LIED AERODYNAMIC MARKER LIGHTS INTEGRAL STOPtTAIUBACKUP LIGHTS WITH 7 EXTRA FEET OF WIRE MOUNTED AT END OF FRAME STANDARD FRONT TURN SIGNAL LAMPS DUAL WEST COAST BRIGHT FINISH HEATED MIRRORS WITH LHAND RH REMOTE DOOR MOUNTED MIRRORS 102 INCH EQUIPMENT WIDTH Prepared by. Ruch Stopczynski Truck Centers, Inc. 1011 W. Sample St. South Bend, IN 46619 Phone: 574-289-4065 rstopczynski@truckoentersinc.com truckoentersinc.com SB121217A - Tandem Diesel Dump bid Page 8 of 13 Prepared for, Board of Public Works City of South Bend IN County City Bldg, South Bend, IN 46601 Description LH AND RH 8 INCH BRIGHT FINISH CONVEX. MIRRORS MOUNTED UNDER PRIMARY MIRRORS STANDARD SIDEIREAR REFLECTORS FIXED CAB MOUNTED STEPS LH AND RH FOR CAB ENTRY, BELLY PLOW BODY WITH HIGH GROUND CLEARANCE 63X14 INCH TINTED REAR WINDOW TINTED DOOR GLASS LH AND RH WITH TINTED NON -OPERATING WING WINDOWS RH AND LH ELECTRIC (POWERED WINDOWS, PASSENGER SWITCHES ON' D,OOR(S) TINTED WINDSHIELD 2 GALLON WINDSHIELD WASHER RESERVOIR WITHOUT FLUID LEVEL INDICATOR, FRAME MOUNTED OPAL GRAY VINYL INTERIOR MOLDED PLASTIC DOOR PANEL WITHOUT VINYL INSERT WITH ALUMINUM IKICKPLATE LOWER DOOR MOLDED PLASTIC DOOR (PANEL WITHOUT VINYL INSERT WITH ALUMINUM KICKPLATE LOWER DOOR BLACK (MATS WITH SINGLE INSULATION DASH MOUNTED ASH TRAY FORWARD ROOF MOUNTED CONSOLE WITH UPPER STORAGE COMPARTMENTS WITHOUT NETTING IN DASH STORAGE BIN (2) CUP HOLDERS LH AND RH DASH GRAY/CHARCOAL FLAT DASH SMART SWITCH EXPANSION MODULE HEATER, DEFROSTER AND AIR CONDITIONER. STANDARD HVAC DUCTING WITH SNOW SHIELD FOR FRESH AIR INTAKE MAIN HVAC CONTROLS WITH RECIRCULATION SWITCH STANDARD HEATER PLUMBING DENSO HEAVY DUTY AIR CONDITIONER COMPRESSOR BINARY CONTROL, R-134A STANDARD INSULATION Prepared by: Rich Stopczynski Truck Centers, Inc. 1011 W. Sample St. South Bend, IN 46619 Phone: 574-289-4065 rstopozynski@truckcenterslnc.com S13121217A -Tandem Diesel Dump bid Page 9 of 13 Preparedfor: Board' of Public Works City of South Bend IN County City (Bldg. South Bend, IN 46601 Prepared by: Rich Stopczynski Truck Centers, Inc. 1011 W. Sample St.. South Bend, IN 46619 Phone: 574-289-4065 rstopczynski@truckcentersinc.com Description SOLID-STATE CIRCUIT PROTECTION AND FUSES 12V NEGATIVE GROUND ELECTRICAL SYSTEM DOME (DOOR ACTIVATED LH AND RH, DUAL READING LIGHTS, FORWARD CAB ROOF LH AND RHI ELECTRIC DOOR LOCKS (1) 12 VOLT (POWER SUPPLY IN DASH PREMIUM HIGH BACK AIR SUSPENSION DRIVER SEAT WITH 3 CHAMBER AIIR LUMBAR, INTEGRATED CUSHION EXTENSION, FORWARD AND REAR CUSHION TIILT, ADJUSTABLE SHOCK ABSORBER BASIC HIGH BACK NON SUSPENSION PASSENGER SEAT DUAL DRIVER SEAT ARMRESTS, NO PASSENGER SEAT ARMRESTS LH AND RH INTEGRAL DOOR PANEL ARMRESTS VINYL WITH VINYL INSERT DRIVER SEAT VINYL WITH VINYL INSERT PASSENGER SEAT BLACK SEAT BELTS ADJUSTABLE TILT AND TELESCOPING STEERING COLUMN 4-SPOKE 18 INCH (450MM) STEERING WHEEL DRIVER AND PASSENGER INTERIOR SUN VISORS MINN GRAY DRIVER INSTRUMENT PANEL GRAY CENTER INSTRUMENT PANEL BLACK GAUGE BEZELS LOW AIR PRESSURE INDICATOR LIGHT AND AUDIBLE ALARM 2 INCH PRIMARY AND SECONDARY AIR PRESSURE GAUGES INTAKE MOUNTED AIR RESTRICTION INDICATOR WITHOUT GRADUATIONS 97 DB BACKUP ALARM MOUNTED INBOARD OF RAIL ELECTRONIC CRUISE CONTROL WITH SWITCHES IN LH SWITCH PANEL KEY OPERATED IGNITION SWITCH AND INTEGRAL START POSITION; 4 POSITION OFF/RUN/START/ACCESSORY ICU3S, 132X48 DISPLAY WITH DIAGNOSTICS, 28 LED WARNING LAMPS AND DATA LINKED 513121217A - Tandem Diesel Dump bid Page 10 of 13 Prepared for: Board of Public Works City of South Bend IN County City Bldg. South Bend, IN 46601 Description HEAVY DUTY ONBOARD DIAGNOSTICS INTERFACE CONNECTOR LOCATED BELOW LH DASH 2 INCH ELECTRIC FUEL GAUGE PROGRAMMABLE RPM CONTROL - ELECTRONIC ENGINE ELECTRICAL ENGINE COOLANT TEMPERATURE GAUGE 2 INCH TRANSMISSION OIL TEMPERATURE GAUGE ENGINE AND TRIP HOUR METERS INTEGRAL WITHIN DRIVER DISPLAY ELECTRIC ENGINE OIL PRESSURE GAUGE OVERHEAD INSTRUMENT PANEL AMIFMIWB WORLD TUNER RADIO WITH CD PLAYER, BLUETOOTH, IPOD INTERFACE, USB AND AUXILIARY INPUTS, J1939 DASH MOUNTED RADIO (2) RADIO SPEAKERS IN CAB AMIFM ANTENNA MOUNTED ON FORWARD LH ROOF POWER AND GROUND STUDS INIUNDER DASH ELECTRONIC MPH SPEEDOMETER WITH SECONDARY KPH SCALE, WITHOUT ODOMETER STANDARD VEHICLE SPEED SENSOR ELECTRONIC 3000 RPM TACHOMETER NO VEHICLE PERFORMANCE MONITOR NO DETROIT CONNECT SERVICES SELECTED NO ZONAR SERVICES SELECTED IGNITION SWITCH CONTROLLED ENGINE STOP (6) IGN CONTROLLED EXTRA SWITCHES WITH IND LIGHTS WIRED TO POWER DIST BOX WITH RELAYS PROVIDING 20 AMPS PER CIRCUIT TO JUNCTION BLOCK AND 1 CIRCUIT AT 30 AMPS PRE -TRIP LAMP INSPECTION, ALL OUTPUTS FLASH, WITH SMART SWITCH BW TRACTOR PROTECTION VALVE TRAILER HAND CONTROL BRAKE VALVE DIGITAL VOLTAGE DISPLAY INTEGRAL WITH DRIVER DISPLAY SINGLE ELECTRIC WINDSHIELD WIPER MOTOR WITH DELAY Prepared by: Rich Stopczynski Truck Centers, Inc. 1011 W. Sample St. South Bend, IN 46619 Phone: 574-289-4065 rtopczynski@truckcentersinc.com SB121217A-Tandem Diesel Dump bid Pagel 1 of 13 Prepared for: Board of Public Works City of South Bend IN County City Bldg, South Bernd„ IN 46601 Description MARKER LIGHT SWITCH INTEGRAL WITH HIEADUGHT SWITCH AND DUAL CONNECTORS AND SWITCH FOR CUSTOMER FURNISHED SNOW PLOW LIGHTS, LOW BEAMS OFF WITH HIGH BEAMS TWO VALVE PARKING BRAKE SYSTEM WITH DASH VALVE CONTROL AUTON'EUTRAL AND WARNING INDICATOR SELF CANCELING TURN SIGNAL SWITCH WITH DIMMER, WASHERIWIPER AND HAZARD IN HANDLE Prepared by: Rich S topczynski Truck Centers, Inc. 1011 W. Sample St. South Bend, IN E46619 Phone: 574-269-4065 rstopczynski@truckcentersinc.com (INTEGRAL ELECTRONIC TURN SIGNAL FLASHER WITH HAZARD LAMPS OVERRIDING STOP LAMPS PAIINT: ONE SOLID COLOR / r CAB COLOR A: L0006EB WHITE ELITE BC BLACK, HIGH SOLIDS POLYURETHANE CHASSIS PAINT POWDER WHITE (N0006EA) FRONT WHEELS POWDER WHITE (N0006EA) REAR WHEELS STANDARD BLACK IBUMPER PAINT STANDARD E COAT/UNDERCOATING U.S. FMVSS CERTIFICATION CiUMMINS L9 ENGINE WARRANTY: 5 YEARS / 150,000 MILES / 100% PARTS AND LABOR CUMMINS AFTERTREATMENT WARRANTY: 5 YEARS / 150,000 MILES 1100% PARTS AND LABOR ALLISON TRANSMISSION WARRANTY: 5 YEARS/UNLIMITED MILES / 100% PARTS AND LABOR SB121217A - Tandem Diesel Dump bid Page 12 of 13 Prepared for: Board of Public Works City of South Bend IN County City Bldg. South Bend, IN 46601 20A FEED AND GROUND, 15A iGNITION FEED DASH CENTER WITH 2'WIRE HARNESS ZiEBART RUSTPROOFING WITH WARRANTY MANUALS FOR ALL EQUIPMENT 1 YEAR SUBSCRIPTION - TROUBLESHOOTING SOFTWARE ACCESS TO PARTS AND SERVICE ONLINE Prepared by: Rich Stopozynski Truck Centers, inc. 1011 W. Sample St. South Bend, IN 46619 Phone: 574-289-4065 rstopczynski@truir,koentersinc.com SB1211217A - Tandem Diesel Dump bid Page 13 of 13