Loading...
HomeMy WebLinkAboutOpening of Bids - Water Treatment Chemicals 2017-2018 - Rowell Chemical Corp0i , 11f tt4 nG CITY OF SOUTH BEND, INDIANA SELLER'S BID FOR SALE OR LEASE OF MATERIALS, BID NAME Water Treatment Chemicals 2017-2018 ` y FOR BIDS DUE March 14, 2017; 9.30 a.m., Local Time Bidder //�� Date: O % (Firm): ROWC:11 CheMje-.S Carp Address: o— C qlxt, SL41k ao1 City/State/Zip: fVnSkaJ;L O ( Telephone Number: Agent of Bidder (if Applicable): When the prospective Contractor is unable to certify to any of the statements below, it shall attach an explanation to this Affidavit. CONTRACTOR'S NON -COLLUSION AND NON -DEBARMENT AFFIDAVIT, CERTIFICATION REGARDING INVESTMENT WITH IRAN, EMPLOYMENT ELIGIBILITY VERIFICATION, NON- DISCRIMINATION COMMITMENT AND CERTIFICATION OF USE OF UNITED STATES STEEL PRODUCTS OR FOUNDRY PRODUCTS (Must be completed for all quotes and bids. Please type or print) STATE OF 1- C ) COUNTY ) SS: The undersigned Contractor, being duly sworn upon his/her/its oath, affirms under the penalties of perjury that: 1. Contractor has not, nor has any other member, representative, or agent of the firm, company, corporation or partnership represented by him, entered into any combination, collusion or agreement with any person relative to the price to be bid by anyone at such letting nor to prevent any person from bidding nor to induce anyone to refrain from bidding, and that this bid is made without reference to any other bid and without any agreement, understanding or combination with any other person in reference to such bidding. Contractor further says that no person or persons, firms, or corporation has, have or will receive directly or indirectly, any rebate, fee, gift, commission or thing of value on account of such sale; and 2. Contractor certifies by submission of this proposal that neither contractor nor any of its principals are presently debarred, suspended, proposed for debarment, declared ineligible, or voluntarily excluded fi•om participation in this transaction by any Federal department or agency; and in Iran. Contractor has not, nor has any successor to, nor an affiliate of, Contractor, engaged in investment activities a. For purposes of this Certification, "Ian" means the government of Iran and any agency or instrumentality of Iran, or as otherwise defined at Ind. Code § 5-22-16.5-5, as amended from time -to - time. b. As provided by Ind. Code § 5-22-16.5-8, as amended from time -to -time, a Contractor is engaged in investment activities in Iran if either: i. Contractor, its successor or its affiliate, provides goods or services of twenty million dollars ($20,000,000) or more in value in the energy sector of Iran; or ii. Contractor, its successor or its affiliate, is a financial institution that extends twenty million dollars ($20,000,000) or more in credit to another person for forty-five (45) days or more, if that person will (i) use the credit to provides goods and services in the energy sector in Iran; and (ii) at the time the financial institution extends credit, is a person identified on list published by the Indiana Department of Administration. 4. Contractor does not knowingly employ or contract with an unauthorized alien, nor retain any employee or contract with a person that the Contractor subsequently learns is an unauthorized alien. Contractor agrees that he/she/it shall enroll in and verify the work eligibility status of all of Contractor's newly hired employees through the E-Verify Program as defined by LC. 22-5-1.7-3. Contractor's documentation of enrollment and participation in the E-Verify Program is included and attached as part of this bid/quote; and 5. Contractor shall require his/her/its subcontractors performing work under this public contract to certify that the subcontractors do not knowingly employ or contract with an unauthorized alien, nor retain any employee or contract with a person that the subcontractor subsequently learns is an unauthorized alien, and that the subcontractor has enrolled in and is participating in the E-Verify Program. The Contractor agrees to maintain this certification throughout the term of the contract with the City of South Bend, and understands that the City may terminate the contract for default if the Contractor fails to cure a breach of this provision no later than thirty (30) days after being notified by the City. 6. Persons, partnerships, corporations, associations, or joint venturers awarded a contract by the City of South Bend through its agencies, boards, or commissions shall not discriminate against any employee or applicant for employment in the performance of a City contract with respect to hire, tenure, terms, conditions, or privileges of employment, or any matter directly or indirectly related to employment because of race, sex, religion, color, national origin, ancestry, age, gender expression, gender identity, sexual orientation or disability that does not affect that person's ability to perform the work. In awarding contracts for the purchase of work, labor, services, supplies, equipment, materials, or any combination of the foregoing including, but not limited to, public works contracts awarded under public bidding laws or other contracts in which public bids are not required by law, the City, its agencies, boards, or commissions may consider the Contractor's good faith efforts to obtain participation by those Contractors certified by the State of Indiana as a Minority Business ("MBE") or as a Women's Business Enterprise ("WBE") as a factor in determining the lowest, responsible, responsive bidder. In no event shall persons or entities seeking the award of a City contract be required to award a subcontract to an MBE/WBE; however, it may not unlawfully discriminate against said WBE/MBE. A finding of a discriminatory practice by the City's MBE/VIBE Utilization Board shall prohibit that person or entity from being awarded a City contract for a period of one (1) year from the date of such determination, and such determination may also be grounds for terminating the contact for which the discriminatory practice or noncompliance pertains. 7. The undersigned contractor agrees that the following nondiscrimination commitment shall be made a part of any contract which it may henceforth enter into with the City of South Bend, Indiana or any of its agencies, boards or commissions. 3 Contractor agrees not to discriminate against or intimidate any employee or applicant for employment in the performance of this contract with privileges of employment, or any matter directly or indirectly related to employment, because of race, religion, color, sex, gender expression, gender identity, sexual orientation, handicap, national origin or ancestry. Breach of this provision may be regarded as material breach of contract. 1, the undersigned bidder or agent as contractor on a public works project, understand my statutory obligations to the use of steel products or foundry products made in the United States (I.C. 5-16-8-1). 1 hereby certify that I and all subcontractors employed by me for this project will use steel products or foundry products on this project if awarded. I understand that violations hereunder may result in forfeiture of contractual payments. 1 hereby affirm under the penalties of perjury that the facts and information contained in the foregoing bid for public works are true and correct. Dated this 1 D1,' day of 20-17 ayUX(( Ch,'mi«.A Contractor/Bidder (Firm) Signature of Contractor/Bidder or Its Agent omasfbrr;s - PCPs;dk F Print d Name and Title Subscribed and sworn to before me this 10"' day of (YCt(CA— , 20 1 My Commission Expires -7118117 Q 2� �7V�dfary Publia�� County of Residence DqRq DAWN M DRASS OFFICIAL Notary P blc, StateoAt Ilinois =+ My Commission Expires July 18, 2017 4 (To be completed only by Contractors/Bidders claiming to be a "local Indiana business" pursuant to I.C. 36-1-12-22) INDIANA LOCAL BUSINESS PREFERENCE CLAIM A "local Indiana business" refers to any of the following: (1) A business whose principal place of business is located in an affected county. (2) A business that pays a majority of its payroll (in dollar volume) to residents of affected counties. (3) A business that employs residents of affected counties as a majority of its employees. (4) A business that makes significant capital investments in the affected counties as defined in rules adopted by the political subdivision. (5) A business that has a substantial positive economic impact on the affected counties as defined by criteria in rules adopted by the political subdivision. An "affected county" refers to St. Joseph County, Indiana, or the following counties located adjacent to St. Joseph County: Elkhart County, Marshall County, Starke County and LaPorte County There are the following price preferences for supplies purchased from a local Indiana business: • 5% for a purchase expected by the purchasing agency to be less than $50,000 • 3% for a purchase expected by the purchasing agency to beat least $50, 000 but less than $100,000, • 1 % for a purchase expected by the purchasing agency to beat least $100, 000. Date: Pursuant to I.C. 36-1-12-22, for Project Joseph County, Indiana. claims a local Indiana business preference (Project # ) located within the City of South Bend, St. The location of the principal place of business is St. Joseph County, Indiana The following county located adjacent to St. Joseph County, Indiana: ❑ The majority of the business's payroll for the 12 months prior to the date of this Bid is to residents of St. Joseph County, Indiana or the adjacent county noted above. ❑ The majority of the business's employees for the 12 months prior to the date of this Bid are residents of St. Joseph County, Indiana, or the adjacent county noted above. If the business is deemed to be the apparent lowest, responsible, responsive bidder, then it shall provide supporting documentation for the 12 month period prior to the date of the Bid of (i) the total payroll amount paid to all employees of the business, and (ii) the total payroll amount paid to employees who are residents of St. Joseph County and the adjacent county noted above. WHEN SUPPLYING SUPPORTING PAYROLL RECORDS, BIDDER SHALL REDACT ALL SOCIAL SECURITY NUMBERS. Dated this day of 20_ Contractor/Bidder(Firm) Signature of Contractor/Bidder or Its Agent Name and Title tip L'l 11 IJ SPECIFICATIONS s CITY OF SOUTH BEND ) 80 BID NAME Water Treatment Chemicals 2017-2018 FOR BIDS DUE March 14, 2017; 9:30 a.m., Local Time BLENDED PHOSPHATE SEQUESTRANT CORROSION INHIBITOR.............................................................................. 10 CHLORINESPECIFICATIONS .............. __..... ......................... .............................................................................. ..................... 2 DRYPOLYMER FLOCCULENT................................................................................................................................................ 17 FERRICCHLORIDE ....... __..................................................................................................................7 FLUORISILICICACID ............. .................................... .... ................................_.......... .... .... .................._.................................... . 8 LIQUIDCALCIUM NITRATE 66%........................................................................................................................................... 18 POTASSIUMPERMANGANATE .... .................................................................... _... .-............................. .................................. 9 SALTSPECIFICATION.- ................................. -................................ .............................................. ............................ ............... 14 SODIUMHYPOCHLORITE 12.5%............... -...... ...................... .___ ...................................................................................... 19 SODIUMPERMANGANATE........................................................... ..................... _........ ....................... 20 SULFURDIOXIDE .................... .... .._..................................... ...................................................................... ___ ......................... 16 FOR ALL CHEMICALS For security purposes vendors shall confirm via fax a copy of the delivery driver's license, truck and trailer information along with the anticipated time of arrival not later than 24 hours Drior to arrival. Failure to do so will be cause for rejection of material, no billable time will be accepted. Water Works facility deliveries are to be made on normal work days between 7: 00 a.m. and 11: 00 a, in. with unloading to be completed before 1: 00 p.m, Waste Water facility deliveries are to be wade between the hours of 6: 00 AMand 4: 00 PMMonday through Friday. No stop -off or fuel surcharges allowed; however, demurrage charges will be allowed after 2 hours per stop, All deliveries are F.O.B. Delivery Point. Awards of this bid will be divisible by product. Awards will be based on the lowest responsive and responsible bidder per unit prices on the attached schedule. All prices quoted are to be effective May 1, 2017 through April 30, 2018 (One Year). Prices are to be film throughout that period without increases. Quantities are estimated and not guaranteed. I. CHLORINE SPECIFICATIONS INCLUDE BOTH 150# AND TON CYLINDERS A. GENERAL 1. Only containers which currently are authorized by regulation for chlorine, which have been inspected and reconditioned as described herein, and which have been tested within the period required by regulations should be filled. It is illegal to ship chlorine containers that have been filled by or without the consent of the owner. 2. Due to the volatile nature of this chemical, the chlorine provider must be able to have one (1) accredited Safety and Handling of Chlorine class per year. 3. Chlorine quotes should be deposit-fi•ee. No cylinder deposit should be included in the quote. Boiling Point -29.29017 (-34.05°C) Critical Density 35.77 lb./cu. ft. Critical Pressure 1118.4 psia (76.1 Atmos.) Critical Temperature 291.20' (144.)C) Critical Volume 0.02796 cu. ft./lb. Latent Heat of Vaporization 123.7 Btu./lb. @13oiling point Liquid Gas Relationship: 1 volume liquid chlorine — wt. at 457.6 volumes of chlorine, 825 @ standard conditions Melting Point -149.76°T (-100.980C) Specific Gravity - Dry Gas 1 2,482 Specific Gravity —Liquid 1.468 0 (° - 4°C) B. CHLORINE 150 POUND CYLINDERS 1. Construction o) All cylinders mast be compatible ivith Chlorine Institute Emergency Kit "A". All kit devices must be useable on any cylinder in chlorine service. The mavimunn neck ring diameter that will accommodate an "A"hood is 4-314 inches. 2. Cylinder Types a) Chlorine cylinders must eonnply with DOT specs, 3A480, 3AA480, 25, 3, 3BN480 or 3E1800. The regulations permit only one opening in chlorine cylinders -at the top for the valve connection. 3. Cylinder Styles a) Cylinders may be of three styles: footring, bumped bottom, at, double botioni. 4. Cylinder Threads a) The threads in new cylinders are NGT threads 314-14NGT(CI). 5. Chlorine Ton Containers a) All ton containers nntst be compatible with Chlorine Institute Emergency Kit "B". 6. Ton Container Types a) Chlorine ton container types nuist comply with DOT spec. 106A500X, DOT or IC'C 106A500. 27, BE27. b) Ton Container Valve and Fuse Plug Opening Threads c) The threads in new ton containers are 314-14NGT (CI). 7. Valve Protection a) The cylinder and ton container valves are protected during shipment and storage by a removable steel valve protective housing or cap. Pressure relief devices shall not be covered by the housing. 8. Cylinder and Ton Container Capacity a) In cases where the capacity of a chlorine container is not known, it can be determined by weighing it empty and again when completely filled with water, and by multiplying the weight of water at 60"F by 1.25, This is the maeimunr allowable weight of chlorine allowed on the cylinder or ton container. C. STAMPING 1. Cylinder Stamping a) When manufactured, cylinders are stamped with DOT specification number, serial mmnber, and oroners and/or builders identifying symbols as well cis inspector's official mark and initial test date [DOT Section 173.34(c)] of 49CFR. 2, Ton Container Stamping a) When manufactured, ton containers are stamped with DOT specification number, material, serial number, inspector's of mark, name, mark or initials of company for whose use the tank is made, (or builder's symbol and serial mmiber), date of test, and water capacity [DOT Section 179.300-18], Tare weights may be stamped by builder. Changes in stamping tnust be made in conhpliarnce with DOT Section 173.31(d) or 49CFR. 3, Retest Stamping a) Retested cylinders [DOT 49 CFR, Section 173,34 (e) (6)) and ton containers [DOT 49 CFR, Section 173.31(d) (7)J must be stamped to show date of retest. For cylinders, the stamp must include the test facility's certification number in a prescribed pattern, Ton containers do not require the lest facility's mmnber on the container. 4. Tare -Weight Stamping a) Il is recommended that all new chlorine cylinder°s and ton containers be stamped with the original tare weight by the container manufacturer. D. VALVES 1. Cylinders a) Chlorine cylinders are to have a single chlorine style Ceodeux D174 valve which is equipped with a fusible metal phig-type relief device. This is a must comply safety requirement. 2. Ton Container Valves a) Chlorine ton containers are to have tivo identical chlorine style Ceodeux D174 valves near the center of one head. This is a must comply safety requirement. When vertically aligned, the valve in the zipper position is used for gas withdrawal, and the lower one for liquid withdrawal The standard ton container valve is identical to the cylinder valve except that it has no fusible metal type relief device, and the valve seat diameter may be larger than on most cylinder valves. There are tow sizes of ton container valves: 314 inch NGT and I inch NGT 3. Valve Outlet Threads a) Outlet threads on cylinder and ton containers are special straight threads (1, 030" - 14NGO-RH-EAT) which conform to eomteelion number CGA 820 and B20C which utilize a yoke -type connection. These threads are to accommodate the outlet cap only and are not to be used for chlorine hose connections. E. PRESSURE RELIEF DEVICES 1. Cylinders a) The relief device on chlorine cylinders is a fusible metal plug in the cylinder valve located below the valve seat. The fusible metal is cast into an Alloy "B"or Alloy "A" holder which is screived into a lapped hole in the valve body. The fusible plugs are designed to inch between 158 degrees F and 165 degrees F. 2. Ton Containers a) Ton contairner valves contain no fusible plugs. The container itself is equipped with six threaded fitsible plugs, three in each head, spaced approximately 120" apart. 3. Ton Container and Cylinder Inspection, Cleaning, and Reconditioning a) In addition to the required period retest, it is recommended that each tort container and cylinder be internally and externally inspected prior to each filling. This includes all appurtenances, such as valves and fusible plugs. Criteriafor such inspection is outlined in "Cylinder and Ton container Procedure for Chlorine Packaging, "Chlorine Institute Pamphlet 17, Sections 3, 4, and 5. F. PERIODIC RETESTING AND RE -INSPECTION 1. Cylinder and Ton Containers to be Tested 4 a) Cylinders (except DOT 3E 1800) and ton containers must be retested at least once in fine years (DOT'Section 173.34e and Section 173.31d). b) Cylinders cannot he filled until they are retested after the fire year anniversary of the month in which it ivas tested Ton containers can be filled until the end of the calendar year during imhich their fire year test is due. c) Retests are also required after any reheat treahnent. In addition, retest any container which shows evidence of weakness at any time, or shoii� a 5 percent or more loss in weight. 2. "rest Procedure a) Cylinders and ton containers are hydrostatically retested by the hydrostatic expansion method [DOT Section 1 73. 34 (a) and Section 173.31 (d)J. If at the time of requalifrcation a container shows a leak or a permanent expansion ro,hich exceeds 10% of the total expansion, it must be condemned. 3. Container Records a) Records must be kept showing results of the test. Each container must have the test date plainly and permanently stanvped into the petal of one head or the chime of each task passing the hydrostatic retest. G. CONDITIONS OF DELIVERY A South Bend Water Works representative shall specify the location for chlorine cylinder and ton container deliveries. 2. Delivery Locations: Location Type of Container Address North Station 2,000 lb. Ton Container 830 North Michigan Street Carriage Hills 150 lb. Cylinder 52290 Shenandoah Drive Erskine 150 lb. Cylinder 4116 South Fellows Street South 1,250 lb. Ton Container 3600 South Main Street Cleveland South 150 lb. Cylinder 4900 Cleveland Road Cleveland North 150 lb, Cylinder 4949 Cleveland Road Waste Water 2,000 lb. Ton Container 3113 Riverside Drive 3. Vendor personnel shall conduct all activities related to the loading and unloading of cylinders. 4. Ton containers will need to be delivered with a cherry picker. 5. Minimum deliveries are two (2) ton containers and twelve cylinders. 6. Supplier must be able to guarantee delivery within five (5) calendar days alter order placement 7. Vendor personnel shall not unload any filled cylinders or ton containers prior to live inspection by South Bend Water Works Personnel. 8. Vendor personnel shall assist South Bend personnel in the visual inspection of each cylinder or ton container for: a) External doniage or defect b) proper installation of ralre protection housing or caps c) Visual inspection of'i,alres andfrisible plugs d) Determination of markings of retest and recertification 9. Motor vehicles used to ship ton containers shall be properly equipped with lift equipment suitable for handling containers to any point where the container is to be loaded upon or unloaded from the vehicle. a) Cylinders containing chlorine shall be securely lashed in an upright positlon, loaded into racks securely attached to the motor vehicle, or packed in boxes or crates of such dimensions as to prerent their overturning. I1, FERRIC CHLORIDE A. GENERAL 1. Normal concentration percent by Weight; 33-35% 2. Specific Gravity: 0.33 B. DELIVERY 1. Full truck deliveries (4500 gallons) to the Ferric feed facility Plant located at; 3113 Riverside Drive, South Bend, IN 46628 IIl. FLUORISILICIC ACID A. GENERAL 1. The Fluorisilicic Acid supplied under these specifications shall be clean and free of visible suspended matter and shall not contain more than 0.020 percent of the "heavy metals", mercury, lead, bismuth and copper expressed as lead (Ph); and shall contain no soluble mineral or organic substances in quantities capable of a deleterious or injurious effect upon the health of those consuming water that has been treated properly with fluorsilicic acid. 2. Product to meet the latest AWWA standard for Fluorisilicic Acid (13703). 3. Price is to be based on a 23% solution. 4. Bidders shall quote price per pound. B. DELIVERY 1. The vendor shall deliver bulk fluoride to the following well locations in the quantities as specified by a representative of the South Bend Water Works. 2. 23% Fluorisilicic Acid delivered in tank truckloads. 3. Deliveries are estimated at thirteen (13) tank trucks with two to four stop -offs per 20,000 lb. load. 4. No stop -off or fuel surcharges allowed however, demurrage charges will be allowed after 2 hours per stop. 5. Suppliers must furnish own unloading hose at least 40 feet in length with proper couplings to hook onto two male N.P.T., and must blow off hose to bulk tank at each stop. 6. City will not accept delivery of more than 10% over the order quantity. 7. Delivery Locations: Location Bulk Tank—T Address North Station 1600 gallons 1 830 North Michigan Street Carriage Hills 0 gallons 52290 Shenandoah Drive Edison 1350 gallons 2708 Rockne Drive Erskine 450 gallons 4116 South Fellows Street South 500 gallons 3600 South Main Street Cleveland South 1100 gallons 4900 Cleveland Road Cleveland North 550 gallons 4949 Cleveland Road Pinhook 1000 gallons 3801 Riverside Drive Olive 1750 gallons 915 South Olive Street IV. POTASSIUM PERMANGANATE A. MATERIAL 1. Free Flowing Grade Potassium Permanganate shall meet the requirements of AWWA Specification 603-98 and shall be manufactured domestically and certified suitable for use in public water supply by appropriate state and federal agencies. B. DELIVERY 1. The potassium permanganate shall be delivered in 55 pound pails made of 24- gauge steel or plastic and shall be equipped with a handle. a) The pails shall reinain the property of the South Bend Water Works. b) The pails shall be unloaded and neatly stacked at the pumping stations. 2. Deliveries will be ordered on an as needed basis with each delivery consisting of approximately 8 to 16 (55 Lb.) pails. 3. Deliveries must be made within 5 days of placement of the order. 4. Vendor shall deliver pails to the following site: a) Water Works North Station — 830 North Michigan Street V. BLENDED PHOSPHATE SEOUESTRANT CORROSION INHIBITOR A. STANDARDS 1. Product shall be a minimum of 85% sodium pyrophosphate. 2. The remaining ingredient(s) shall also be sodium phosphate material(s). Product must already be listed in the latest National Sanitation Foundation (NSF) Standard 60 directory. 3. The percent phosphate as PO4 must be disclosed and by Indiana law, be marked on the outside of the container. B. TECHNICAL ASSISTANCE 1. The successful vendor giving a quote must also provide on -site technical assistance to the Authority for an eight hour day per month for the first six months of product usage. 2. After the first 6 months of on -site technical assistance, the Authority will request further on -site technical assistance on an as needed basis. 3. The vendor shall provide a per visit cost in their quote for the additional site visits. 4. Each visit will be one workday (Monday through Friday only), from 7:00 a.m. to 3:30 p.m. EST. 5. Vendor must submit the name(s) and resume(s) of the technical representative that will perform the on -site assistance with your quote submittal. 6. The technical representative shall be an employee or certified representative of the vendor and have a minimum of three years of experience in the application of blended phosphate sequestering products in municipal water supply and be available Monday through Friday from 7:00 a.m. to 3:30 p.m. EST to answer questions which may arise in applying their product. C. REQUIREMENTS 1. A list of two municipal references within a one hundred mile radius of South Bend using the product for a minimum of one year. 2. Each reference must include the name of the municipality, the superintendent's name, and phone number. 3. A one pint sample must be submitted with bid for analysis. 4. During the contract period, additional sampling and analysis will be made. 5. Contract can be nullified if testing indicates unauthorized changes have been made to product. 6. Samples of product being used by references may also be sampled. 7. Evaluation 10 a) Sample product analysis b) Reference interview and possible sample analysis c) Verification of ingredients. 8. Testing a) The City reserves the right to submit samples of the polyphosphate product to an independent laboratory of the City's choice for chemical, biological, and physical analysis and testing. b) Any product which, in the City's opinion, contains hazardous or deleterious substance or fails to comply with these specifications will be disqualified. c) The cost of this analysis and testing will be incurred by the vendor with the understanding that a maxinun of ten samples per year will be submitted. d) Guaranteed mininnrn ovailable phosphate percentage as PO4 is to be Eighty Percent (80%). 9. Other evaluation: a) List of data that confirms products effect on (a) copper, (b) sequestration b) List of data that confirms company' experience in other cities and technical support. 10. Certified Analysis a) The supplier shall provide a certified chemical analysis of a polyphosphate product sample taken from the production facilityfrom which he proposes to supply the City gfSoufh Bend. b) He shall fiirther cert f, analysis to be representative of the product he proposes to provide the City. 11, Performance Requirements a) When applied at a rate yielding not more than four (4) parts ofpolyphosphate as PO4 to each part of iron and manganese, the product shall be capable of'holding iron and manganese in solution for no fewer than five (5) days at seventy (70) degrees Fahrenheit in the presence of one-half milligram per liter (0.5 mg/1) free chlorine residual and for no less than hmenty four (24) hours at 140 degree F. b) The City reserves the right to run performance tests once a month. c) Any product which, in the City's opinion, does not meet the specfted performance requirements orfails to comply with the specifications will be disqualified. D. COVERAGE 1. These specifications cover blends of phosphate compounds used to stabilize or sequester soluble iron and manganese in potable water. E. PHYSICAL FORM 1. Product shall be a granular form. Powdered material will not be accepted. F. PHYSICAL STANDARDS 1. Phosphate blend shall comply with the following physical requirements: a) Color: White b) Solubility: Completely miscible in inter c) Percent Phosphate as PO4 Minimum Qf'80% d) Physical Form: Granular G. CHEMICAL STANDARDS 1. Phosphate blend shall contain only NSP approved phosphorous ingredients. 2. No amines or other chelating agents shall be used. 3. Blended phosphate product formulation shall be only sodium salts of phosphate compounds. 4. No potassium salts shall be used. 5. Impurities in polyphosphate products shall not exceed the following concentrations: Arsenic as AS 0.001 mg/I Copper as CU 0.2 mg/1 Heavy Metals (total as Ph) 0.001 mg/I Iron FE 0.1 mg/1 Manganese as MN <.05 mg/I Organics as C None Silica as SIO2 1.0 Zinc as ZN 0.01 mg/1 In addition to the above standards, polyphosphate products shall contain no substance, for which the Indiana Pollution Control Board has established a limit in potable water, in a concentration exceeding the limit established for potable water. H. PACKAGING & DELIVERY 1. Product shall be shipped in 50 pound bags and stored locally. 2. Deliveries are to be made within two to three days of notice. 3. Vender will be required to deliver product weekly or as needed to each well field in order to maintain specified stock levels. 4. Weekly delivery receipts will be issued. 12 5. Delivery sites are as follows: Location Address Carriage Hills 52290 Shenandoah Drive Erskine 4116 South Fellows Street South 3600 South Main Street Cleveland South 4900 Cleveland Road Cleveland North 4949 Cleveland Road 13 VI. SOLAR SALT SPECIFICATION A. GENERAL 1. The salt will be used to prepare a saturated brine solution which will be used as a chloride source for the on -site hypochlorite generator. 2. Bids will be all inclusive. 3. Solar salt/Purex manufactured by Morton Salt (or equal) shall be supplied in bulk deliveries and blown into the brine saturator tank using the supplier's truck -mounted blower. 4. The existing brine saturator tank has the capacity to receive 25-ton bulk deliveries. 5. Equipment such as hoses with the 4" quick disconnect shall be provided with salt delivery by the provider. 6. Off-loading truck air pressure shall not exceed 10 p.s.i. for every salt delivery. B. PRODUCT 1. Salt for sodium hypochlorite generation 2. To ensure proper operation of the on -site hypochlorite generator, solar salt shall meet or exceed the following quality parameters: Description Percent Maximum/ Minimum Water Insoluble 0.01% maximum Calcium Nitrate 0.140/, maximum Magnesium Sulfate 0.02% maximum Magnesium Chloride 0.1% maximum Sodium Chloride 99.82% minimum NaCl Wet 93.3% minimum NaCl Dry 96.3% minimum Moisture (as H2O) 3% maximum Lead 0.0007% maximum Cop er 0.0003% maximum Iron (as Fe) 0.002E maximum Fluoride 0.01% 1 maximum 3. Sodium Chloride content shall be determined per the AWWA B200-03 standard or per ASTM Standard Methods. 4. Salt shall be certified to ANSI/NSF Standard 60 when the sodium hypochlorite solution produced by the electrolytic generator will be used for disinfection of drinking water. 5. Salt shall contain no anti -caking or free -flowing additives or conditioners. 14 6. Salt shall be medium, coarse or extra coarse grade with a minimum bulk density of 60 lb/ft3 to avoid use of gravel bed in brine saturator tank. C. PHYSICAL PROPERTIES 1. Purex or Equal a) The pour (loose) bull( density shall be 115-1.25 ghnl (72-78 lbs/fP). b) Production shall be unscreened, receiving a coarse scalping of 10-141nesh. The mean crystal size shall be 290-430 um. c) The mean sznface area of the crystals shall be 65-98 cm. sq/g. d) Sodium Chloride content shall be determined per the AWWA B200-03 standard or per ASTM Standard Methods. e) Morton's Purex or equal shall be certified to ANSI/NSFStandard 60 1,rhen the sodiznn hypochlorue solution produced by the electrolytic generator Will be used for disinfection of drinking ivater. f) Morion's Purex or equal shall contain no anti -caking orfree flowing additives or conditioners. D. DELIVERY LOCATIONS: 1. Edison Filtration Plant, 2708 Rockne Drive, South Bend, IN 2. Olive GAC Building, 915 S. Olive Street, South Bend, IN 15 VII. SULFUR DIOXIDE A. PROPERTIES Boiling Point -10°C Color Colorless Specific Gravity (80°F) 1.363 Critical Temp. 314.82°F Critical Pressure 1141.5 PSIA B. USAGE 1. Estimated annual usage is 100 tons, more or less, to be delivered in 2,000 lb containers of liquid S02 in truckload lots of 10 containers. C. DELIVERY 1. Supplier must be able to guarantee delivery of 10 tons (20,000 lbs) within five (5) calendar days fi•om release of requirement. 2. Material to be delivered F.O.B. 3. No fi•eight surcharges allowed. 4. Billing must be submitted on a CWT unit basis. 5. Delivery Location: Waste Water Treatment Plant located at 3113 Riverside Drive, South Bend, Indiana 46628. 16 V1II. DRY POLYMER FLOCCULENT A. GENERAL 1. The purpose of this specification is to outline minimum acceptable properties of a polymer at the Bureau of Waste Water in the treatment process. 2. Quantity of the polymer stated in this specification is intended as an estimated usage during a 12 month period rather than an absolute quantity. 3. Polymer is considered a performance product and must meet certain standards due to compliance related issues on the NPDES Permit. 4. Any supplier that has not been previously approved must perform bench testing on any polymer bid to prove the product will meet the standards necessary to ensure permit compliance. 5. When samples are required, such samples shall be delivered or shipped at the vendor's expense to the following name and address: Nancy Clay, 3113 Riverside Dr. South Bend, IN 46628, 6. Samples must be clearly labeled with your company's name, address, and (item number). 7. All samples must be representative of the item bid. 8. All samples will become the property of the City of South Bend, and will not be returned. B. PROPERTIES 1. Products will be a high molecular weight cationic polyelectrolyte, supplied as a micro -bead or in granular form. 2. The product must be completely non -dusting, free flowing and completely soluble in water with a very rapid dissolving rate. 3. Typical Properties Bulk Density 50 lbs. per cubic ft. Particle Size 95% less than 1 mm PH of 1% Solution 3.5 —4.5 C. PACKAGING/DELIVERY 1. Packaging to be in 50 — 55 lb polyethylene bags. 2. Must be able to guarantee delivery of 9,000 lbs within 14 calendar days after order placement. 3. Prices must be submitted in cost per pound with fi•eight included. 4. Material to be delivered F.O.B. the Waste Water Treatment plant located at 3113 Riverside Drive, South Bend, IN. 46628. 17 IX. LIQUID CALCIUM NITRATE 66% A. GENERAL 1. The estimated annual usage of Liquid Calcium Nitrate (66%) is 45,000 gallons, more or less. 2. Supplier must be able to guarantee delivery of 4,000 to 5,200 gallons within five (5) calendar days after order placement. B. TYPICAL PROPERTIES Concentrations: Ca(NO3)2 46.34% Ca(NO3)2. 4H20 66.5% Ca 11.2% Mn (ppm) Less than I Specific Gravity: 1.454 g/ml at 20°C pH: 6.00 at 20°C C. DELIVERY 1. Full truck load quantities are to be approximately 3,500 gallons 2. Delivery will be to two separate remote locations. Geyer Ditch GPS location 41.69565,-86.40614, Sage Road GPS location 41,71024,-86.41629. 3. Remote locations are accessed via a combination lock. Delivery requests will include the combination lock if City personnel will not be on -site during deliveries. If City personnel will be on -site the combination will be omitted from the manifest. 4. Prices must be submitted in cost per gallon with freight included. In X. SODIUM HYPOCHLORITE 12.5% A. GENERAL 1. The estimated annual usage of Sodium Hypochlorite is 30,000 gallons, more or less. 2. The City owns multiple 2,550+ gallon tanks for the storage of Sodium Hypochlorite 12.5%. 3. These tanks come equipped with all necessary fittings and outlets, as well as secondary containment for increased safety. 4. Supplier must have necessary hoses and connectors to connect to a 2 inch quick disconnect fitting. 5. Product delivered to a Water Filtration Facility must meet the required ANSI/NSF Standard 60. B. TYPICAL PROPERTIES Concentrations Sodium Hypochlorite 12.5% Specific Gravity 1.1964 PH 12.5 to 13.5 Molecular Weight 74.44 Boiling Point >212°F Freezing Point -11°F C. DELIVERY 1. Supplier must be able to guarantee delivery of 1,800 to 4,500 gallons within seven (7) calendar days after order placement. 2. Full truck load quantities of approximately 1,800 to 4,500 gallons are to be delivered, F.O.B. to: a) Waste Water Treatment Plant, 3113 Riverside Drive, South Bend, IN. 46628. b.) Pinhook Filtration Plant, 2801 Riverside Drive, South Bend, IN 46628, c.) Edison Filtration Plant, 2708 Rockne Drive, South Bend, IN 46615. 3.) Prices must be submitted in cost per gallon with freight included. 19 XI. SODIUM PERMANGANATE A. GENERAL: 1. The bid will be for two separate line items for the same product (20% Liquid Sodium Permanganate) 2. One line item will be for deliveries of 275-gallon totes. 3. The other will be for deliveries between 500 and 550 gallon increments. B. TYPICAL PROPERTIES I . Product shall be bulk 20% (by weight) +/- 0.5% liquid sodium permanganate (NaMnO4). 2. 20% Liquid Sodium Permanganate shall be produced domestically with in the United States. 3. Product shall meet or exceed ANSI/AWWA standard B603-03 or subsequent revisions. 4. Product shall be listed by the NSF as being in full compliance with NSF Standard No. 60 for Drinking Water Treatment Chemicals — Health Effects. C. DELIVERY 1. All deliveries shall be made within 48 hours of the request to the following address: 2801 Riverside Drive, South Bend IN 46628, 2. The product is to be delivered in clean containers/tanks and is free of contamination. Contamination of stock shall render the contractor liable for disposal of contaminated material, cleanup of storage facilities and full replacement of stock at the Supplier's expense. 3. All deliveries shall be made on weekdays (excluding holidays) between the hours 7:00 AM and 11:00 AM 4. The off-loading of the 275-gallon totes containing sodium permanganate from the delivery vehicle to the City's storage location will be performed by pressurizing the container to our point of delivery or by transfer pump. 5. Deliveries must be coordinated with the City. The Identity of the driver must be made known by fax or email 24 hr. prior to delivery. The delivery vehicle operator must call the City contact no less than one hour prior to delivery. 6. The Contractor and shipper shall be responsible for all health, safety, and costs associated with the transportation of the product to the Pinhook WTP. 2801 Riverside Drive 46628. 7. The City reserves the right to reject any delivery which does not conform to these specifications or which has been contaminated. 20 BIDIPROPOSAL CITY OF SOUTH BEND BID NAME Water Treatment Chemicals 2017-2018 FOR BIDS DUE March 14, 2017 ; 9:30 a.m., Local Time Item Estimated Item Quantity/Y Unit Unit Price Extended No ear I Chlorine — 1 Ton Cylinders 150 Ton $ �� a A NO 6; d 2 Chlorine — 150 Lb. Cylinder 150 Cyl. $ o `Ji d No R' d 3 Ferric Chloride 90,000 Gal. $ o nf0 U: 4 Fluorisilicie Acid — 23% 260 Ton $ 5 Potassium Permanganate — 55 Lb. 7,500 Lbs. Q Pails $ j0i N(7 f� 6 Blended Phosphate Sequestrant 22,500 Lbs. $ NO bid I%O 0( 7 Solar Salt 125 Ton $ 00 id IV6 Aza g Sulfur Dioxide — I Ton Cylinders 100 Ton $ O �i A)o; O( 9 Dry Polymer Flocculent — 50 / 55 Bag 40,000 Lbs. $ 00 61 N 61 d Lb, Polyethylene rJ D 10 Liquid Calcium Nitrate 25,000 Gal. $ (llpQjty NO PJ+� 11 Sodium Hypochlorite — 12.5% 30,000 Gal. $ ��j 3 SaO• W 12 Sodium Permanganate 2,200 Gal. Q $ 1VD �Jid Vo g ; 275 Gallon Totes 13 Sodium Permanganate Bulk 2,200 Gal. QQ A0 vl� CVO 61 d 500-500 Gallon Bidder (Firm): Rome CyleiVll� �Or�fah� Address: �� �f G.eek- Cc,", �u1►e aoC Telephone City/State/Zip: 4%ds4ale .J-C Wfr( Number: Printed Name (Signat re) Title; Pre5t 1 e L� 21 BOARD OF PUBLIC WORKS Gary A. Gilot, President Elizabeth A. Maradik, Member Therese J. Doran, Member M. Fritzberg, Member James A. Mueller, Member Attest: Linda M. Martin, Clerk 22 Bid or Proposal Bend Westfield Insurance Company Westfield Insurance® 1 Park Circle, P O Box 5001, Westfield Center, Ohio 44251-5001 Toll Free 500-243-0210 KNOW ALL MEN BY THESE PRESENTS, that we, RoNvell Chemical Corporation as Principal, and the Westfield insurance Company an Ohio Corporation, with its principal office at Westfield Center, Ohio, as Surety, are held and family bound unto South Bend IN as Obligee, in : the penal sure of Threo Thousand Ono Hundred Fifty Dollars and zero cents - $3,150.00 DOLLARS, lawful money of the United States of America, for the payment of which, well and truly to be made, we bind ourselves, our heirs, executors, administrators, successors and assigns, jointly and severally, family by these presents. WHEREAS the said Principal is herewith submitting a bid or proposal for Sodium Hypocblorite NOW THEREFORE, the condition of the above obligation is such, that if the said Principal shall execute a contract and give bond for the faithful performance thereof if required by the contact, or if the Principal or Surety shall pay the Obligee the difference, not exceeding the penal sum hereof, between the amount of the contract entered into in good faith to perform the work to which the bid or proposal relates and the amount bid or proposed by the Principal, then this obligation shall be void; otherwise it shall remain in full force and effect. SIGNED this 10' day of W CtrC1L- 0GAJPI( (-h & i(--J 60QQOAct'6v�,n Principal By: � `71�mas l�rriS p��s�drpnfi BA $046 General POWER NO. 0997432 00 Power Westfield Insurance Co. of Attorney Westfield National Insurance Co. CERTIFIED COPY Ohio Farmers insurance Co. Westfield Center, Ohio Know All Men by These Presents, That WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY, corporations, hereinafter referred to Individually as a "Company" and collectively as 'Companies; duly organized and existing under the laws of the State of Ohio, and having Its principal office in Westfield Center, Medina County, Ohio, do by these presents make, constitute and appoint DANA R. LUDWIG, ANGELA CARTER, ANJA MAKOSKY, JOINTLY OR SEVERALLY of CLEARWATER and State of FL its true and lawful Altorney(s)-In-Fact, with full power and authority hereby conferred In Its name, place and stead, to execute, acknowledge and deliver any and all bonds, recognizances, undertakings, or other instruments or contracts of suretyship- - - - - ------------- - -- - -- -.- - -- -- LIMITATION: THIS POWER OF ATTORNEY CANNOT BE USED TO EXECUTE NOTE GUARANTEE, MORTGAGE DEFICIENCY, MORTGAGE G AI'TRANTEE, OR BANK DEPOSITORY BONDS, and to bind any of the Companies thereby as fully and to the same extent as if such bons were signed by the President, sealed with the corporate seat of the applicable Company and duly attested by Its Secretary, hereby ratifying and confirming all that the said Attorneys) -In -Fact may do In the premises, Said appointment Is made under and by authority of the following resolution adopted by the Board of Directors of each of the WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY: "Be it Resolved, that the President, any Senior Executive, any Secretary or any Fidelity & Surely Operations Executive or other Executive shall be and Is hereby vested with full power and authority to appoint any one or more suitable persons as Attorney($) -In -Fact to represent and act for and on behalf of the Company subject to the following provisions: The Attorney -In -Fact may be given full power and authority for and in the name of and on behalf of the Company, to execute, acknowledge and deliver, any and all bonds, recognizances, contracts, agreements of Indemnity and other conditional or obligatory undertakings and any and all notices and documents canceling or terminating the Company's liability thereunder, and any such Instruments so executed by any such Attorney -In -Fact shall be as binding upon the Company as If signed by the President and sealed and attested by the Corporate Secretary.' 'Be It Further Resolved, that the signature of any such designated person and the seal of the Company heretofore or hereafter affixed to any power of attorney or any certificate relating thereto by facsimile, and any power of attorney or certificate bearing facsimile signatures or facsimile seal shall be valid and binding upon the Company with respect to any bond or undertaking to which it Is attached' (Each adopted at a meeting held on February e, 2000). In Witness Whereof, WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY have caused these presents to be signed by their National Surety Leader and Senior Executive and their corporate seals to be hereto affixed this 07th day of JANUARY A.D., 2015 . Corporate ro^tl"y '� °0Nnt """ WESTFIELD INSURANCE COMPANY Seats ��`e y :ANCS °�PK1•••••^•�'l'SG•;• ;,r•" \NS.... k , WESTFIELD NATIONAL INSURANCE COMPANY Affixed yr; .a. `no; A _ T • e OHI/O� FARMERS INSURANCE COMPANY Eft J+r7'Ta,M..4 jA =�i SEAL im= lea NV s:'° State of Ohio q "p°" " By: Dennis P. Baus, National Surety Leader and County of Medina ss.: Senior Executive On this 07th day of JANUARY A.D., 2015 , before me personally came Dennis P. Baus to me known, who, being by me duly sworn, did depose and say, that he resides In Wooster, Ohio; that he Is National Surety Leader and Senior Executive of WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY, the companies described In and which executed the above Instrument; that he knows the seals of said Companies; that the seals affixed to said Instrument are such corporate seals; that they were so affixed by order of the Boards of Directors of said Companies; and that he signed his name thereto by like order. Notarial R..a•"e.wgy, Scat AP\ A L Affixed State of Ohio County of Medina ss.: David A. Kotnik, Attorney at Law, Notary Ictrbllc My Commission Does Not Expire (Sec. 147,03 Ohio Revised Code) 1, Frank A. Carrino, Secretary of WESTFIELD INSURANCE COMPANY, WESTFIELD NATIONAL INSURANCE COMPANY and OHIO FARMERS INSURANCE COMPANY, do hereby certify that the above and foregoing Is a true and correct copy of a Power of Attorney, executed by said Companies, which Is still In full force and effect; and furthermore, the resolutions of the Boards of Directors, set out in the Power of Attorney are In full force and effect. In Witness Whereof, I have hereunto set my hand and affixed the seals of said Companies at Westfield Center, Ohio, this day of r7T.rMla 2 E SEAL imc w Secretary :?o Ike, 1648. ; Frank A• Carrino, Secretary BPOAC2 (combined) (06.02) �Lr) oo O O �H Q cad O Ir TI � 0 1� ' � z 00 9 R C) f0if � 1� AlJ iC � u F9 u U ¢Qrn 0 NSF International OFFICIAL LISTING NSF International Certifies that the products appearing on this Listing conform to the requirements of NSF/ANSI Standard 60 - Drinking Water Treatment Chemicals - Health Effects This is the Official Listing recorded on December 30, 2015. Rowell Chemical Corporation 15 Salt Creek Lane Suite 205 Hinsdale, IL 60521 630-920-8833 Facility: Willow Springs, IL Chemical/ Trade Designation Sodium Hydroxide Rcc Sodium Hydroxide 10% Rcc Sodium Hydroxide 15% Rcc Sodium Hydroxide 1616 Roc Sodium Hydroxide 18.5% Rcc Sodium Hydroxide 20% Rcc Sodium Hydroxide 25% Rcc Sodium Hydroxide 30% Rcc Sodium Hydroxide 40%, Rcc Sodium Hydroxide 50% Sodium Hypochlorite [CL1 Hypo 100 Hypo 150 Hypo 52 Function Max Use Corrosion & Scale Control 500 mg/L PH Adjustment Corrosion & Scale Control 333 mg/L PH Adjustment Corrosion & Scale Control 312 mg/L PH Adjustment Corrosion &Scale Control 270 mg/L PH Adjustment Corrosion & Scale Control 250 mg/L PH Adjustment Corrosion & Scale Control 200 mg/L PH Adjustment Corrosion & Scale Control 167 mg/L PH Adjustment Corrosion & Scale Control 125 mg/L pH..Ad?ustment. Corrosion & Scale Control 100 mg/L PH Adjustment Algicide 105 mg/L Bactericide Disinfection & oxidation Algicide 84 mg/L SaCteri4lde Disinfection & Oxidation Algicide 200 mg/L Bactericide Disinfection & oxidation (CLI The residual levels of chlorine (hypochlorite ion and hypochlorous acid), chlorine dioxide, chlorate ion, chloramine and disinfection by-products shall be monitored in the finished drinking water to ensure compliance to all applicable regulations. Note: Additions shall not be made to this document without prior evaluation and acceptance by NSF International. 1 of 1 CO248409 789 N. Dixboro Road, Ann Arbor, Michigan 48105-9723 USA i-800-NSF-MARK / 734-769-8010 www.nsforg ROWELL Chemical Corporation 15 Salt Creek Lane Suite 205 Hinsdale, Illinois 60521 6301920-8833 Fax: 6301920-8994 10100 S. Archer Ave. Willow Springs, Illinois 60480 708-839-1707 Fax: 708-839-1725 SODIUM HYPOCHLORITE - HYPO 150 STANDARD GRADE SPECIFICATIONS MINIMUM TYPICAL MAXIMUM SODIUM -HYPOCHLORITE, Weight Percent 12.5 13.40 15:0 AVAILABLE CHLORINE CONCENTRATION Weight Percent 11.9 12.76 14.29 Volume (Trade) Percent 14.27 15.50 17.74 Grams per Liter 142.7 155.0 177.4 EXCESS CAUSTIC SODA Weight percent 0A 0.175 2.0 Grams per Liter 2.1 SPECIFIC GRAVITY at 20° 1.199 1.215 1.242 SOLUTION WEIGHT, POUNDS PER GALLON 10.01 10.13 10.36 INERT INGREDIENTS, Weight Percent Salt (NaQ 11.0 SodiumCarbonate <0.5 12.5 Inorganic salts of copper and iron 1.5 2.0 Other Inorganic salts <0.1 0.1 Standard spec updated 11/18/16; KLK Filename: Hypo 150 - Standard Grade - 2016-1118 gp0 Ng�0 ;; b®C n m 0 rrR's ot� [M ROWELL Chemical Corporation SAFETY DATA SHEET Section 1— Product and Company Identification Product Name: HYPO 150, Bleach, Sodium I Iypochlorite Product Code: IIYPO150, Rowell Chemical Corporation Telephone Numbers: 15 Salt Creek Lane — Suite 205 During normal business hours: (630) 920-8833 Hinsdale, IL 60521 Transportation emergency call Chemtrec: (800) 424-9300 Product Use: Industrial It is a violation of federal law to use this product in a manner inconsistent with its labeling Not recommended for: Household use Section 2 — Hazards Identification GHS Ratings: DANGER Corrosive to metals 1 Skin corrosive 1B Eye corrosive 1 Oxidizing liquid 3 Organ toxin single exposure 3 Aquatic toxicity C2 GHS Hazards EUH031 Contact with acids liberates toxic gas H272 May intensify fire, oxidizer H314 Causes severe skin burns and eye damage H335 May cause respiratory irritation H400+H411 Very toxic to aquatic fife with long lasting effects SDSfor Hypo Printed Corrosive to metals Destruction of dermal tissue Serious eye damage, Irreversible damage May intensify fire, oxidizer Transient target organ effects: Respiratory, Inhalation Acute toxicity and lack of rapid degradability GHS Precautions P234 Only keep in original container P261 Avoid breathing dust/fume/gas/mist/vapors /spray P264 Wash hands thoroughly after handling P271 Use only outdoors or in well -ventilated area P273 Avoid release to the environment P280 Wear protective gloves/protective clothing/eye protection/face protection P310 Immediately call a Poison Control Center or doctor/.physician P321 Specific treatment (See section 4 or First Aid section of the label) P363 Wash contaminated clothing before reuse P391 Collect spillage P301+P330+P331 IF SWALLOWED: Rinse mouth. DO NOT induce vomiting. August 29, 2016 Page 1 of 7 ROW11,111 clivillind I orponlioll P303+P361+P353 IF ON SKIN (or hair): Remove/take off immediately all contaminated clothing. Rinse skin with water/shower P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing P305+P351+P338 IF IN EYES: Rinse continuously with water for several minutes. Remove contact lenses if present and easy to do — continue rinsing P405 Store locked up P406 Store in a corrosion resistant container with a resistant .liner P403+P233 Store in a well ventilated place. Keep container tightly closed P501 Dispose of contents/container to appropriate waste site or reclaim in accordance with local and national regulations Hazardous Components Chemical Name Identifiers 0/4 (weight) Sodium Hy ochlorite 7681-52-9 12.50—15.00% Sodium Hydroxide 1310-73-2 0-5% Inhalation: Remove from further exposure. For those providing assistance, avoid exposure of yourself. Use adequate respiratory protection. If respiratory irritation, dizziness, nausea or unconsciousness occurs, seek immediate medical assistance. If breathing has stopped, a trained individual should attempt to resuscitate while medical assistance is obtained. Call a poison control center or physician for treatmentadvice. Eye Contact: Rinse cautiously with water for at least 15 minutes. Remove contact lenses if present and easy to do. Continue rinsing and contact medical assistance. Skin Contact: Remove all contaminated clothing. Flush skin with water for at least 15 minutes, then wash with soap and water. Contact medical assistance for advice. Ingestion: If victim is conscious, give 1-2 glasses of water or nulls. Do not give anything to an unconscious victim. DO NOT induce vomiting and seek immediate medical assistance. Notes to Physician: Probable mucosal damage may contradict the use of gastric lavage. Corrosive material 5DS for Hypo printed': August 29, 2016 page 2 of 7 r ROWELL Chrmirod Corporalion SAFETY DATA SHEET Section 5 — Fite Fighting Measures Flammable Limits: Flash Point: Not flammable UEL: NA LEL: NA Extinguishing Media: Use extinguishing agent suitable for type of surrounding fire. Unusual Fire or Explosion Hazards: No data available Hazardous Combustion Products: Hydrogen Chloride, Chlorine (if in contact with metals), Oxygen, Sodium Chlorate Advice for Firefighters: If evacuation of personnel is necessary, evacuate to an upwind location. Decontaminate personnel and equipment with water wash -down after fire and smoke exposure. Structural firefighters' protective clothing may only provide limited protection. Wear positive pressure self-contained breathing apparatus (SCBA). Move containers from fire area if you can do it without risk. Use water spray to cool containers exposed to fire. Section 6 — Accidental Release Measures Personal precautions, protective equipment and emergency procedures Personal Precautions: Wear appropriate protective equipment including respiratory protection as conditions warrant. Do not touch or walk through spilled material. Do not touch damaged containers or spilled material unless wearing appr9priate;proteot ive clothing. Emergency Procedures: As an immediate precautionary measure, isolate spill or leak area. Keep out of low areas. Keep unauthorized personnel away. Stay upwind. Ventilate closed spaces before entering. Environmental Precautions: Avoid run off to waterways and sewers. Methods and material for containment and cleaning up Small Spills: Stop leak if you can do it without risk. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers for later disposal. Large Spills: Dike far ahead of liquid spill and prevent entry into waterways, sewers, basements or confined spaces. Neutralize with Sodium Sulfite (1 teaspoon in 2.5 gallons material) or dilute Hydrogen Peroxide (1 cup inl gal of water .then use on spill). May also neutralize using ''/. teaspoon Ascorbic acid for each gallon of liquid. DO NOT use vinegar or acidic solutions on spill, [his wi# produce dangerous gases. SDS for Hypo Printed: August 29, 2016 Page 3 of 7 ROW11a.i. (tt'tttind (aor,tttniliolt SAFETY DATA SHEET Wear all appropriate Personal Protective Equipment (PPE). Wear respiratory protection or ensure adequate ventilation at all times as vapors can accumulate in confined or poorly ventilated areas. Use the product in a manner which minimizes splashes. Keep containers closed when not in use. Storage: Prevent material from freezing. Store at room temperatures, i.e., 40 to 95°F (4 - 35°C). Store away from direct sunlight and heat to slow normal decomposition. Do not handle or store material near heat, sparks, open flames or other sources of ignition. Chemical Name/CAS No. OSHA Exposure ACGIH Exposure Other Exposure Limits Limits Limits STEL 2 mg/Ms Sodium Flypochlorite 7651-52-9 NA NA AII-IA Sodium Hydroxide 1310-73-2 2 to>/m' TWA 2 m /m' Ce lhi NA Engineering Controls: Ensure that eyewashes and safety showers are close to the workstation. Ventdlation Controls: Provide adequate ventilation to control airborne concentrations below the exposure guidelines. Administrative Controls: No Data Available Personal Protection: As prescribed in the OSHA Standard for Personal Protective Equipment (29CFR 1910.132), employers must perform a hazard assessment of die workplace to determine the need for proper PPE for each employee. Eye Protection: Normal industrial eye protection of safety glasses/goggles and faceshield. Sldn Protection: Avoid contact with skin. Wear long sleeved protective clothing. Wash hands before breaks and itmnediatcly after handling product. Respiratory Protection: If airborne concentration limits are exceeded, an approved respirator must be worn. Contaminated Equipment: Decontaminate equipment with a water wash -down. SDS for Hypo Printed: August 29, 2016 Page 4 of 7 r R0117ELL Chemical corporation SAFETY DATA SKEET Section 9 — Physical and Chemical Properties Density: 1.084 -1.226 @ 20°C/68°F Freezing Point:-11°F/-240C for 12.5% NaOCL by wt. Boiling Point: 219°F/1040C for 12.5% NaOCL by wt. Solubility: Complete Evaporation Rate: Not Available Appearance: Clear, yellow liquid Physical State: Liquid pH: Strong Base >12 Odor/Odor Threshold: Chlorine/0.9 mg/m3 Partition Coefficient (n-octanol/water): Not Available Section 10 — Stability and Reactivity Wt. Melting Point:-11°F/-240C for 12.5% NaOCL by wt. Vapor Density: Not Available Vapor Pressure: 12mmHg for 12.5% NaOCL by wt. Flammability: Not Flammable Flash Point: Not Flammable Decomposition Temperamre: Not Available Autoignition Temperature: Not Flammable Explosive Limits: Not Explosive Stability: Solution decomposes slowly. Decomposition rate increases in temperature >40°C/104°F and sunlight. Incompatibilities: Avoid contact with strong acids which releases chlorine gas, Nitrogen compounds, Ammonium salts, Methanol or metals. Hazardous Decomposition Products: Hydrogen chloride, Chlorine, oxides of Chlorine, oxygen, Sodium Chlorate Hazardous Polymerization: Will not occur. Section 11— Toxicological Information Component Toxicity: Compound LD50 LD50 LC50 Other Mode, species, level Mode, species, level Mode, species, level Mode, species, level Sodium oral, mouse, Dermal, rabbit, NA NA Hypoultionte 5.81, / >20 /-,,k Sodium Intraperitoneal, LDLO, oral, rabbit, NA NA Hydroxide mouse, 40 mg/kg 500mg/kg Routes of Entry: Ingestion, Inhalation, Skin, Eyes Target Organs: No Data Found Effects of Overexposure: Causes severe skin bums and eye damage. Harmful if swallowed or absorbed through skin. May cause respiratory irritation, coughing, dizziness, nausea, or unconsciousness. Mucosal damage, vomiting. SDS for Hypo Printed: August 29, 2016 Page 5 of 7 iioWi'll Ghemiral Gorporalioo Product Ecotoxicity: No data available Component Ecotoxicity: Component Ecotoxicity values Sodium Hypochlorite 96 Hr LC50 Pimephales promelas; 0.06 - 0.11 mg/L Pow -through];; 96 Hr LC50 Pimephales promelas; 4.5 - 7.6 mg/L [static]; 96 IIr LC50 Lepomis macrochirus; 0.4 - 0.8 mg/L [static]; 96 Hr LC50 Lepomis macrochius: 0.28 -1 mg/L [flow -through]; 96 IIr LC50 Oncorhynchus myldss: 0.05 - 0.771 mg/L [flow -through]; 96 Hr LC50 Oncorhynchus mykiss: 0.03 - <0.19 mg/L [semi -static]; 96 Hr LG50 Oncorhynchus myk iss: 0.18 - 0.22 mg/L [static] 48 1 e EC50 Daphnia ma na: 0.033 - 0.044 m /L [Static] Sodium Hydroxide 100 ing/1, Daphnia, minnows, lethal; 40 - 240 mg/l, Daphnia magna, toxicity threshold; ,125 - 1000 mg/l, various insect larvae, lethal-, 25 mg/l, 24hr, brook trout, lethal; 70 tng/l, 5hr, fish, crabs, lethal; 90 mg/l, 4.5hr, oysters, lethal, salt water; 180 m /l, 23hr, oysters, lethal, salt water Sax 1986). Section 13 — Disposal Product Disposal: Pesticide wastes may be hazardous. Improper disposal of excess pesticide, spray mixture or rinsate is a violation of Federal law. If these wastes cannot be disposed of by use according to the label instructions, contact your State Pesticide, Environmental Control Agency or the Hazardous Waste Representative at die nearest EPA Regional Office for guidance. Container Disposal: Clean the container according to label instructions before final disposal. The following is for US DOT Highway transportation. Other modes/jurisdictions may have different classifications, US DOT: Hypochlorite Solutions, UNI 791, III, 8, Marine Pollutant SDS for Hypo Printed: August 29, 2016 Page 6 of 7 r � HOWELL Chemical Corporation SAFETY DATA SHEET Section 15 — Regulatory Information This listing is to highlight federal level regulation of the product. Individual States and other nations may have further regulations not fisted below. US DOT List of Marine Pollutants (172.101- Appendix B) 7681-52-9 Sodium hypochlorite US DOT List of Hazardous Substances and Reportable Quantities (172.101 Appendix A) 7681-52-9 Sodium hypochlorite 12.5% 1310-73-2 Sodium Hydroxide 15.0% US DOT List of Severe Marine Pollutants (172.101- Appendix B) - None SARA Section 302 Extremely Hazardous Substances (40 CFR 355): - None Sara Section 302 Threshold Planning Quantity. - None SARA Section 313, Toxic Chemicals (40 CFR 372.65): - None SARA Reportable Quantity. 7681-52-9 Sodium hypochlorite 12.5% 1310-73-2 Sodium Hydroxide 15.0% Toxic Substances Control Act (TSCA): All components are listed or exempt from the Toxic Substances Control Act except those listed below. - None Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1985 (SARA): This product contains a chemical or chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, part 372. Section 16 — Other Information HEALTH HAZARD FIRE HAZARD I. oaol Flashp&li I kai1F I S t IA3.0 Ve, e AWMOq RII p PI A1ne.IW mnn - o wail W. ZA I.m" VIA- AK kit.AElb �� > Ifuak Xnetin...-m l� 1 .'kF.aN MW..........urr i.YiYNItkMnl kh.em�k+........P NIP PtlIwNR..._....._V I. LLssbffiilAnld UIa Ka WIk,........... W O. Sblk SPECIFIC HAZARD INSTABILITY PERSONAL PROTECTION INDEX A R G! JJk c if I OZ aYSTAeiumr E 61- KWItA \ 1 �n PPE Date Prepared: 8/29/2016 Reviewer Revision: 4.0 The information contained herein is offered only as a guide to the handling of this specific material and has been prepared in good faith by Rowell Chemical Corporation. It is not intended to be all-inclusive and the manner and conditions of use and handling may involve other and additional considerations. No warranty of any kind is given or implied and Rowell Cherical Corporation xviR not be liable for any damages, losses, injuries or consequential damages which may result from the use or reliance on any information contained herein. SDS for Hypo Printed: August 29, 2016 Page 7 of 7