RE: Professional Services Agreement — City of South Bend Data Center Space to Co -
Locate Server, Storage and Network Cabinets
Dear Mr. Carlton:
The Board of Public Works, at its meeting held on November 8, 2016, approved the above
referenced agreement in the amount of $705.00/month, plus a one-time charge of $2,020.00.
Enclosed please find the original of the agreement for your signature. Please sign and return
the original agreement to our office and retain a copy for your records.
If you have any further questions regarding this matter, please call this office at (574) 235-
9251.
Sincerely,
Linda M. Martin, Clerk
Enclosure
c: Michael Sniadecki, Information Technologies
GARY A. GILOT SUZANNA M. FRITZBERG ELIZABETH A. MARADIK JAMES A. MUELLER THERESE J. DORAu
SCHEDULE [A]
to
MASTER SERVICES AGREEMENT
between
Data Realty Northern Indiana, LLC.
("DRNI")
and
City of South Bend
("Customer")
1. Reference to Agreements. This Exhibit is executed pursuant to the Master
Services Agreement dated October 2016 ("Agreement"), executed by the undersigned, and
shall be deemed to be a part thereof.
2. Description of Services. DRNI will provide Data Center Services to Customer. The
following details the services ("Services") to be provided under this Schedule:
a) Data Center Space The data center space will be used by Customer to co -locate
server, storage, and network cabinets.
The data center space has the following characteristics:
i. Security — Security is provided using biometric hand scanners for
authorized access. CCTV - state of the art video surveillance is installed
at each entrance, around the external facility, and in all data and core
infrastructure rooms. Security desk performs 24x7 monitoring. There is
a secure fenced area around generators and cooling towers. Security
Systems are powered by a redundant UPS infrastructure.
ii. Cooling — The facility has two (2) chilled water systems with an initial
redundant mechanical load capacity of 250 Tons and an overall capacity
of 750 Tons for initial building. Chiller Plant is an N+1 design with a
single pathway and will provide process cooling for the space. These
systems shall maintain proper temperature and humidity levels for
appropriate equipment operation using a closed -loop high -efficiency
chiller system. Chillers are magnetic bearing / oil free, with evaporative
condensers. The chilled water systems are designed to operate twenty-
four (24) hours per day, three -hundred sixty-five (365) days per year.
The systems are designed to allow for individual unit maintenance
and/or replacement without affecting the overall cooling of the space.
iii. The average temperature and humidity will be maintained at levels in
accordance with published ASHRAE TC9.9 Data Center Standards. If
ASHRAE standards change Data Realty will maintain compliance with
current standards.
DRNI Co -Location Schedule Page 1 of Revised August 26, 2016
IV. Fire Suppression — The data center space is protected by an inert gas
fire protection system. Installation of FM-200 within raised floor area,
pre -action within Mechanical, Electrical & Plumbing areas.
V. Monitoring — DRNI shall provide continuous monitoring of all critical
support equipment via both electronic and human means. Sensors will
be installed to monitor ambient temperature, humidity and to provide
leak detection, and the data center will be staffed 24x7x365.
vi. UPS — Designed as a Distributed Catcher system transferring load at the
PDU level. Each UPS output distribution panel serves individual branch
circuit panel boards to furnish "A" and "B" redundant branch circuit UPS
power capabilities to each Customer cabinet. The power circuits are
arranged so that one (1) circuit is providing conditioned power to
Customer's cabinet from UPS-1 and the other circuit is providing
conditioned power from UPS-2. Customer must install equipment
which allows for dual power supplies. It is the Customer's responsibility
to connect appropriately. Custom power delivery systems can be
designed on a per Customer basis.
vii. Telecommunications — DRNI provides a carrier neutral facility with
diverse entry points, dual meet -me -rooms and copper or fiber cross
connected as requested by Customer. Multiple fiber carriers are
available. Selection and configuration of network services is
responsibility of Customer. DRNI can provide contact information for
several carriers who provide Internet and/or private bandwidth services
at the DRNI data center. Customer is responsible for selection and
configuration of all external network services which may be required
including any required equipment, software, or implementation
services. Fiber hand-offs use Single Mode Fiber.
viii. Generators — Two 1500kW generators equipped with dedicated sub-
base fuel tanks, fully redundant starting and charging systems, and fuel
monitoring and scrubbing systems are located on site. Fuel storage is
maintained to provide a minimum 48-hour run time, with contracted
refill schedules with redundant carriers. The generators will be load
tested regularly.
ix. HVAC — DRNI utilizes eight (8) 40 ton CRAH Units installed within each
CRAH gallery for cooling supported by a water -based system fed from a
redundant chiller system. CRAH units are provided with dual electrical
sources with integral automatic transfer switches. Ambient air is
utilized in the cooling process to lower cooling costs and increase
efficiency. DRNI will maintain cooling capacity with a minimum of (N
+1) redundancy on all systems. One (1) redundant CRAH for every three
(3) required for capacity. UPS rooms are each supported by (2)
dedicated and redundant 6-ton CRAH Units with independent water
feeds
DRNI Co -Location Schedule Page 2 of Revised August 26,2016
b) Power - Power distribution is provided via a distributed redundant A-B-C
scenario. Redundant electrical systems to support mechanical loads are also
installed, including separate galleries for transformer placement.
Power is fed, and monitored for quality from above cabinet redundant power
bus ways. All power will be delivered in an N+1 fashion.
c) Cross -Connections: DRNI will provide [TBD] cross -connections to Customer for
[$50) each per month. Where carrier services allow, and as requested by
Customer the cross -connects will be arranged so that one is feeding into the
Customer's chosen carrier's primary cabling infrastructure and the other into the
carrier's secondary cabling infrastructure. It is the Customer's responsibility to
ensure that its network equipment allows for dual network connections and is
configured appropriately.
If additional cross -connects are required, they may be purchased at $50 monthly
per physical connection. DRNI will schedule and supervise the installation of
copper or fiber cross -connects as requested in writing by Customer, and invoice
Customer for the cost of cross -connect installation as described in (3) and (4)
below.
d) Blanking Panels: Not later than 30 days after Customer relocation DRNI will
install cold aisle blanking panels on all open rack space in Customer cabinet(s).
DRNI will supply the blank panels.
e) Remote Hands: DRNI's on -site technical staff can provide maintenance,
installation, and assistance with equipment located within the Customer's
collocation environment. Remote Hands is a technical service designed to
support Customers on -site at DRNI who require assistance installing or trouble
shooting equipment. Our technical staff is available on -site 24x7x365 to provide
services such as:
• Rebooting or power cycling equipment.
• Pushing a button, toggling a switch or setting an externally accessible dip -
switch.
• Relaying status of equipment status indicators or typing commands on pre -
installed consoles.
• Plugging in a console port for remote management by Customer.
• Moving or securing cables.
• Installing or removing equipment (e.g. router/switch, externally accessible
components, etc.)
• Swapping of media
• Replacing or verifying connectivity integrity of DRNI provided cross -connects.
• Adding, removing, or verifying a demarcation label.
• Basic troubleshooting of Customer equipment.
DRNI Co -Location Schedule Page 3 of 5 Revised August 26, 2016
• Taking digital pictures of equipment or co -location space.
• Labeling equipment and cable connections.
• Assisting Customer with physically installing, relocating, or movement of
equipment.
• Installing or swapping pre -configured equipment or components.
• Installing cross -connects from Customer equipment to cabinet patch panels.
• Moving or securing cables or Customer -side cross -connects.
• Assist with critical data backup and/or restore tasks
Other customized services can and will be available and detailed in a separate
agreement.
3. Monthly Service Fees. Cost of Services are stated below:
Item Name
Item Description71ncluded
hly
ge
Redundant Power (kW)
Amount of kW allocatedlb
Allocated to Cabinet(s)
power and cool installe0
For Equipment &
equipment in one (1) ca
Cooling
Redundant Single PhasePower
Circuits
x 30a circuits; Up to 4.8
ed
available in cabinet.
Data Center Space
One (1) 48U cabinets.
1
Included
Included
Cabling connections into the
Cross Connections
Customer's chosen carrier as
13
$35
$455
described in 2(c) above
Remote Hands
As described in 2(e) above
1 hour free
$75 / hr.
above 1
TBD
per month
hours
Total Estimated
Monthly Recurring Cost
$705
Redundant power allocated above is based on customer estimate of power required to
energize and cool installed equipment. If more power is actually required MRC will be based
on the actual number of kW required to energize and cool installed equipment,
rounded up to the nearest integer, at the stated rate per kW.
DRNI Co -Location Schedule Page 4 of 5 Revised August 26, 2016
4. One-time Set up Fees. Cost of Services are stated below:
Item Name
Item Description
Cost per Unit
One Time
Char e
Setup Colocation &]new
Design, set up and placement of [1)
Transition Services
cabinet on Row 1, C17
$1,500
$1,500
Installation of initial cross connections
Cross Connects
will be invoiced directly from Metronet
$350
$0
or Martell. Otherwise $350 each.
Redundant Cabinet
[2] Supplied by DRNI
$260
$520
PDU's
Relocation Project
Management
As requested b Customer
q y C
$160 /hour
TBD
Total One Time Charges
$2,020
Set Up Fees. The one time fees will be invoiced upon execution of the contracts. Other
one time fees, if any, will be due and invoiced as services are completed or equipment
delivered to the Customer.
Initial Term. 36 months; The term begins December 1, 2016. On each yearly
anniversary of the Commencement Date, the Monthly Recurring Cost will increase by an
amount equal to two percent (2%) per annum over the then current Monthly Recurring
Cost.
By signing below, the parties agree to the terms and conditions set forth in this Schedule with
the effective date being the last date signed.
City of South Bend (Customer)
APPROVED
By:
Data Realty Northern Indiana (DRNI)
A
Name: Richard F. Carlton
Title: President
DRNI Co -Location Schedule Page 5 of 5 Revised August 26, 2016
INTER -OFFICE MEMORANDUM
Information Technologies Department
227 W Jefferson Blvd (574) 245-6000
TO: Board of Public Works, Linda Martin
CC: Dan O'Connor, Michael Schmidt, George King, John Murphy,
Shawn Delahanty
FROM: Michael E. Sniadecki
SUBJECT: Data Realty -Data Center
DATE: 10/27/16
Members of the Board,
Please see the attached Master Services Agreement between Data Realty & COSB for
you to review and approve. COSB had been migrating servers and storage (data) into
virtual environment in the Cloud over the past year. We are now at the point that we can
setup our upgraded core network environment and move majority of our remaining HW
(servers, storage, network devices & others) from our CCB 1211 floor server room, if not
also from other locations into the Data Center at Data Realty. The Office of Innovation
and Technology team has reviewed the quote and gave favorable recommendation. We
will be moving into this Data Center that will provide protection and redundancy in every
area necessary for uptime availability of 100% such as:
• Security
• HVAC/Cooling
• Fire Suppression
• Monitoring
• Power/UPS/Generators
• Telecommunications
• Others
There is an agreement in place between Data Realty and COSB where COSB gets the
actual rack space free in exchange for Data Realty using some of COSB's conduits. The
monthly recurring cost for this full rack is $705 with a one -charge of $2020. This a
average monthly saving of $900 compared to a regular client would be paying.
This Data Center Co -location will become COSB's primary server room. If it is unable to
be put into the virtual environment in the Cloud, it will be hosted in this Data Center. The
current CCB 1211 floor server room will become a much needed office space for the
Office of Innovation & Technology Dept.
Thank you,
Michael E. Sniadecki
BOARD OF PUBLIC WORKS
AGENDA ITEM REVIEW REQUEST FORM
Date
Name
10/27/16
Michael Sniadecki Department Innovation & Tech
BPW Date 11/08/16 Phone Extension 6004
Required Prior to Submittal to Board
Legal ® Attorney Name Michael Schmidt
Controller ® Controller review is required for all Contracts $5,000.00 or more and
greater than one year in length per the City Purchasing Policy
Purchasing
Check the Appropriate Item Type — Required for All Submissions
® Agreement ❑ Contract ❑ Proposal ❑ Addendum
® Professional Services I -I Resolution
Bid Opening ❑ Bid Award ❑ Req. to Advertise ❑ Title Sheet
Quote Opening ❑ Quote Award
Change Order No. ❑ C/O & PCA No. ❑ PCA
Ease/Encroach. ❑ Traffic Control
Other:
Company or Vendor Name A-8+ 0,NT-
New Vendor ❑ Yes ® No ❑ If Yes, Approved by Purchasing
MBE/WBE Contractor ❑ MBE ❑ WBE
MBEM/BE Contractor Requested ❑ No ❑ Yes Name of Company
Project Name Data Realty -Data Center (Hosting Facility)
Project Number n/a
Funding Source IT Operating & Professional Services
404-0672-415-36-04 (IT Operating) & 404-0672-415-31-06
Account No. Professional Fee
Amount $ 705.00 (MRC) — IT Operating & $ 2,020.00 (One Time Charge) -
Professional Services
Terms of Contract Statement of Work
Purpose/Description Data Center -COSB will be using Data Center space to co -locate
other locations.
❑ Required Contractor's Certification Form Attached (Non -
Collusion. Non -Discrimination. Non-Deharment F-VPrifv Iran Pt!
Amount of " Increase
❑ Decrease
Previous Amount $
Current Percent of Change:
New Amount
Total Percent of Change:
Copy
Original
®
❑
❑
❑
❑
❑
For Change Orders On
Dispersal After Approval
Michael Sniadecki