HomeMy WebLinkAboutSB-0215 1995 Grauvogel Letter re ACM at 814 - 818 Lafayette/fW\
Grauvogel Associates
October 1995 \\\1_._r11
\j
City of South Bend
Community and Economic Development
1200 County-City Building
South Bend IN 46601
Attention Mr John Stark
Subject Asbestos-Containing Materials Survey
814/18 South Lafayette Street
Dear John
We have completed our survey sampling and analysis for suspected asbestos-containing
materials for this structure.We organized these materials into 10 homogeneous areas of like
materials based on the type of material its use and its probable date of installation There are
three categories of suspected asbestos-containing friable materials ACM surfacing SM
which includes plaster and acoustical sprays thermal systems insulation TSI which includes
pipe and vessel insulation and miscellaneous material MM which includes floor tile ceiling
tile drywall and linoleum The results of the sampling and analysis are summarized in the
attached table
The remaining suspect materials floor tile and roofing are EPA Category regulated ACM
RACM non-friable materials These were assumed to contain asbestos to save analysis costs
These materials can remain in or on the building when it is demolished but must be reported to
IDEM and EPA in the required notifications
As shown in the tables there were no friable asbestos-containing materials identified in the
building in addition to the floor tile and roofing assumed to contain asbestos Thus no asbestos
abatement will be necessary prior to demolition of the building
We will proceed with preparation of the IDEM notification for these Category materials to
which you will have to add the demolition contractors name the intended start date and check
for $50.00 The completed form should be mailed to
Cashier
Department of Environmental Management
Office of Air Management
100 North Senate Avenue
P0 Box 6015
Indianapolis IN 46206-6015
17660 Fall Creek Drive Granger Indiana 46530 219 277-4770
814/18 South Lafayette ACM
95049 10/5/95
Page2of4
Thank you for this opportunity to serve you Please direct further questions to the undersigned at
your convenience
Sincerely
Grauvogel Associates
PE CIH CSP
Attachments Form and Form 814/18 South Lafayette Street
Laboratory Report SciLab
sbend/acmfrt 100595 .doc
814/18 South Lafayette ACM
95049 10/5/95
Page of
Form Revl/94
Project South Bend Redevelopment
Building 814/18 South Lafayette Street
HOMOGENEOUS AREA LOG
Friable Class Size
HA Homogeneous Area HA ACM Non-friable SM/TSI/
F/NF MM SF/LF
01 ceiling wall plaster base coat SM 5650 SF
02 drywall ceiling behind plaster/untaped MM 3000 SF
03 fissured ceiling tile MM 280 SF
04 pinhole ceiling tile MM 150 SF
05 linoleum NF MM 120 SF
06 ceiling wall plaster finish coat SM 5650 SF
07 chipboard ceiling non-suspect material NF MM N/A
08 new drywall untaped MM 100 SF
09 floor tile NF MM 400 SF
10 roofing felt NF MM 3000 SF
ACM Asbestos-containing building material as defined by OSHA
Assumed to contain asbestos not sampled OSHA PACM
No Sampled and found negative for asbestos content
Yes ACM either Assumed or Inown
Known sampled and found to be ACM or non-ACM
Friable material as defined by OSHA
NF Non-friable material
MM Miscellaneous material as defined by AFIERA
TSI Thermal system insulation as defined by AHERA
SM Surfacing material as defined by AHERA
SF Square feet
LF Linear feet
814/18 South Lafayette ACM
95049 10/5/95
Page4of4
Form Rev 1/94
Project South Bend Redevelopment
Building 14/18 South Lafayette Street
SAMPLE LOG
Bldg Project Sample
Sample Location
________95049 01 01 plaster SW corner ceiling base coat
________
95049 06 02 plaster SW corner ceiling finish coat
________95049 02 03 ceiling drywall SW corner
95049 01 04 plaster wall center base coat
________95049 06 05 plaster wall center finish coat
_________
95049 01 06 plaster center ceiling at offices base coat
________95049 06 07 plaster center ceiling at offices finish coat
________95049 03 08 main office ceiling tile
________95049 04 09 office hallway ceiling tile
95049 01 10 plaster wall center base coat
________95049 06 11 plaster wall center finish coat
________95049 08 12 drywall at top of basement stairs
OCT 95 E845 SCIL 9333SCIENTIFItLABORATORIESINC
Sonthiake Boulevard 42 Weet 24th Street
Richmond VIrginia 23236 New York New York 10010
Phone 804/3794084 Phone 212/741-2053
Fax 804/319.1087 Fax 212/741-2056
Conpany Ad4res
_____
Project ntormatlcn Analypis Turnarosmd Time Air Filter
Typc 6-She 12he 24hr 48he 72he 5day Other Information
Name
______IIIrEM/W _____________________ Q.45um
Nwnbort _______ ________ ______________SOtun
Maragan
Site City/State _________________ _______________________
Reaulta to L0 Samples Ys No
Invoice to .i4
max -rq ..1
Written capon
COMMENTS
_______________
Sample lD Sample Locati4ai Start Stop Total Uteea/AIR Date
____________________
Titrie Time Mitt Voiw Coliroted
o--t1 -sti-___
_____________9jj _____________ ______________z-o4 ____________ ____________or Pail _____
Cj.ttstt rC CU _____-04 -g tt
0...________________.-
to Ogto-e ii4
OCT 95 95 9845 SCIL4B P.3
Evioumenl1 Lab Sviees
SCIENTIFIC LABORATORIES INC
477 Southlalce Blvd Richmond IVirginia 23236 804/379-1084 FAX 804/379-1087
PLM Buik Asbestos Report
Orauvogel Associates Date 1eceived 9t29/95 SeiLab Job NO 09951333
Attn Laiiy Grauvogel Date Ixamined 10/595 P.O 95049
l766OlallQeekDrive
IN 46530 RE 84/18 South Lafayette
Client No HGA Lab No Asbestos Present Total Asbestos
049-01-01 09951333-01 No NAD
Location Ceiling Plaster-SW
Description Beige lIon3ogeneos Bulk Material
Asbestos Types
Other Material Cellulose 10 Non-fibrous 90
049-06-02 09951333-02 No NAD
Location Ceiling Plaster-SW
Description Beige flomogeneois Bulk Material
Asbestos Types
Other Material Cellulose Non-fibrous 95
049-02-03 09951333-03 No NAD
Location Ceiling Drywall
Description Beige Homogeneo9s Bulk Material
Asbestos Types
Other Material Cellulose 20 Non-fibrous 80
049-02-04 09951333-04 No NAD
Location Wall Plaster-S
Description Beige Homogeneots Bulk Material
Asbestos Types
Other Material Cellulose Non-fibrous 98
049-06-05 09951333-05 No NAL
Location Wall Plaster-S
Description White Hornogcncots Bulk Material
Asbestos Types
Other Material Cellulose 10 won-fibrous 90
OCT 05 95 u846 5CILB P.4
cI
SCIENTIFICj LABORATORIES INC
477 SouthIake Oivd Richmond VirginIa 23236 804/379-1084 FAX 804/379-1087
PLM BuUc Asbestos Report
Granvogel Associates Date Received 9/29/95 SciLab Job No 09951333
Attn Lazry Grauvogel Date Examined 10/595 P.O 95049
17660Fa1lCreekDriv
Granger IN 46530 RE 8j4/18 South Lafayette
Client No HGA Lab No Asbestos Present Total Asbestos
049-01-06 0995 j3334 No NAD
Location Ceiling Plaster-N Cnrer
Description Beige Homogeneoqa Bulk Material
Asbestos Types
Other Material Cellulose on-fibrous 98
049-06-07 09951333-07 No NAD
Location Ceiling Plaster-N Center
Description White Homogeneois Bulk Material
Asbestos Types
Other Material Non-fibrous 100
049-03-08 09951333-08 No NAD
Location 2x4 Ceiling Ti1c-Fisured
Description Tan Hoxnogcneous Bulk Material
Asbestos Types
Other Material Cellulose 95 Jlon-flbrous
049-04-09 09951333-09 No NM
Location 2x4 Ceiling T1le-Pinio1e
Description Tan Homogeneous Bulk Material
Asbestos Types
Other Material Cellulose 95 Nonfibrous
049-01-10 09951333-10 No NAD
Location Wall Plaster-N Cenlr
Description Off White/Tan Hoziogeneous Bulk Material
Asbestos Types
Other Material Cellulose 15 4on-fibrous 85
OCT 95 9946 SCILB P.S
Envkounental Lab Services
SCIEN1IFICLAB0RATORIES INC
477 Southlake Blvd Richmond VIrginia 23236 804/379-1084 FAX 804/379-1087
PLM Bulk Asbestos Report
Grauvogel Associates Date Received 9/29195 SciLab Job No 09951333
Attn Larry Grauvogel Dale Examined 10/5/95 P.O 95049
17660 Fafl Creek Drive
Granger IN 46530 RE 84/18 South Lafayette St
Client No HGA Lab No Asbestos Present Total Asbestos
049-06-11 09951333-11.1 No NAD
Location Wall P1asterN Ccntffr
Description White Homogeneois Scratch Coat
Asbestos Types
Other MaterIal Non-fibrous 100
049-06-11 09951333-11.2 No NAD
Location Wall Plaster-N Centr
Description Beige Homogeneous Bulk Matciial
Asbestos Types
Other Material Cellulose Non-fibrous 97
049-08-12 09951333-12 No NAD
Location New Drywal1-Basericnt Stairs
Description Off White Homogeieous Bulk Material
Asbestos Types
Other Material Cellulose 20 on-fibrous 80
Reporting Notes
Mtelyzod by Ocorgie 1fl
7AD1NSD tee aebeetci 1A endl Bulk beetot Analysis per 40 CPR 763 Subpect Appendix
end EL.P Anslycis Protocols l98I/198A Mew Yoic eamplea Mete PLM to not coneletendy cobble lit detecting
eubeato lit floor oveeinge and aimilor non-friable orgenicpliy bound tenSle TEf ii currently the on1y method that
can be uecd to determine if thie material eon be considore5 or treated at n-cab containing in New York State
also see EPA Advisory for floor tUc FR 59 146 35970 8/1/94 Netionel Institute of Stundurde end Technology
Accreditation requirements mandate that thie report moot not be reprodocod except in full with the approval of the
laboratory This report rolateo ONLY to the items touted
MRS Signatosy