HomeMy WebLinkAboutSB-0215 1991 ATEC Soil Sampling & Testing Report - Lot 5ATEC Environmental
ConSUltants
Solid Hazardous Waste Site AssessmentsDivision of ATEC Associates Inc Remedial Design Construction
5150 East 65th Street
Underground Tank Management
Indianapolis Indiana 46220-4671 Asbestos Surveys Analysis849-4990 FAX 849-4278
Hydrogeolugic Investigations Monitoring
Analytical Testing/Chemistry
August 13 1991 Industrial Hygiene/Hazard Communication
Environmental Audits Permitting
Eoploratory Drilling Munitcring WellsMrK.C Pocius
Department of Economic Development
Suite 1200
County City Building
South Bend IN 46601
Re Summary Report
Soils Sampling and Testing
Lot Murdocks
Studebaker Corridor
South Bend Indiana
ATEC Project Number 21-17237
Dear Mr Pocius
ATEC Environmental Consultants ATEC has completed hand auger soil sampling
program at the above-referenced property The purpose of the soil sample collection and
analysis was to determine if contamination may be present in the subsurface soils at this site
due to drum storage area and one underground storage tank UT The objective was
accomplished by advancing total of seven hand auger borings This summary report
provides description of the work performed and makes recommendations based on the
analytical findings
Work Performed
Four borings were advanced at locations surrounding the drum storage area which are
designated are HA-I HA-2 HA-3 and HA-4 These samples were located adjacent to the
drum storage areas Sample depth intervals for each sample were to 12 inches These soil
samples were submitted for VOCs testing in the laboratory
Three borings were advanced near the UST Soil samples were collected from each
boring at depth between 10 and lift This sample depth interval allowed samples to be
Subsidiary v/American Testing and Engineering Ccrpcrutiun Consulting Envirvnmenta/ Geotechnical and
Offices in Majvr US Cities Since 1958 Materials Engineers
collected below the bottom depth of the UST As reported to ATEC by Mr Calvin
Murdock the dimensions of the UST are ft in length and ft in diameter comprising
1000 gallon tank Soil samples were submitted for Total Petroleum Hydrocarbons TPH
testing in the laboratory
All samples were collected preserved and transported to ATECs laboratory in Indianapolis
Indiana for analysis following all proper chain-of-custody procedures total of seven
soil samples were collected at specific locations at the project site Four samples were
tested for VOCs and three samples were tested for TPH Test results for samples HA
1HA-2 HA-3 and HA-4 showed concentrations of carbon disulfide Samples HA-2 and HA-
showed concentrations of petroleum constituents present Sample HA-4 showed 111-
Trichloroethane TCA detected however below quantitation limits The table below
provides summary of the analytical results for samples collected at this project site
complete copy of the analytical report is attached to this report
Soil Sample Test Results
Volatile Organic Compounds
Lot Murdocks
Studebaker Corridor
Parameters HA HA HA HA4 HA HA HA
Carbon disulfide 10 180 NT NT NT
111-TCA ND ND ND NT NT NT
Benzene ND ND NT NT NT
Toluene ND 10 14 NT NT NT
Ethylbenzene ND ND NT NT NT
Total Xylenes ND ND NT NT NT
TPH NT NT NT NT ND ND ND
All reported values in parts per billion ppb
111-TCA 111-Trichioroethane
TPH Total Petroleum Hydrocarbons
ND Not detected
NT Not tested
The client should note that methylene chloride were reported as being detected in samples
Methylene chloride is used as laboratory extraction solvent for various organic analyses
Although the extraction and preparation processes are all performed by trained personnel
in separate rooms under vented fumehood some vapors escape and are released into the
laboratory atmosphere The release of these vapors into the laboratory atmosphere is
basically random process dependent upon daily usage and the care and diligence of
laboratory personnel involved in handling the solvents Once these compounds are released
into the atmosphere they can contaminate any sample once it is removed from the sample
container and exposed to the atmosphere Given the extreme sensitivity of the analytical
instrumentation these compounds are often detected in low levels in environmental samples
The U.S EPA1 recognizes concentrations of these contaminants up to five times the
quantitation limit as laboratory artifacts
Upon review of the analytical data there were no UST borings with TPH results reported
above quantitation limits However several VOC parameters were detected in boring
locations near the drum storage areas
Conclusions and Recommendations
Based on these soil test results there was no obvious evidence found to show the UST has
caused gross contamination as result of past use However soil samples near the drum
storage area show low concentrations of certain volatile organics Concerning this matter
ATEC recommends that second round of soil samples be collected and tested for VOCs
The purpose of the second round of samples is to determine the possible extent of the VOC
constituents in the soils surrounding these areas
ATEC recommends that this UST be properly closed to include removal according to
Indiana Department of Environmental Management IDEM protocol
Verbal statement made by the U.S EPA to ATEC at pre-bid conference September 1988
Our professional services have been performed our findings obtained and our
recommendations prepared in accordance with customaiy principles and practices in the
fields of environmental science and engineering This warranty is in lieu of all other
warranties either express or implied This company is not responsible for the independent
conclusions opinions or recommendations made by others based on the field exploration
and laboratory test data presented in this report
We trust this submittal is responsive to your needs If you have any questions or comments
regarding this report or if we can be of any further service to you in the future please do
not hesitate to contact us
Very truly yours
ATEC Associates Inc
urtis Gilham
Staff Environmental Scientist II
Matthew Stokes C.H.M.M
Senior Project Manager
MCS/ca