Laserfiche WebLink
ASTM D6694 <br />PHYSICAL PROPERTIES ASTM Test Result Requirement <br />Tensile Strength @ 73°F D2370 275 psi 150 min <br />Elongation at Break @ 73°F D2370 196% 100 min <br />Tensile Strength @ 0°F D2370 176 psi 150 min <br />Elongation at Break @ 0°F D2370 113% 100 min <br />Tear Resistance (Die C) D624 24 lbf/inch 20 min <br />Permeance – 20 mils DFT @ 73°F / 50% RH E96 – B 6.4 Perms 2.5 min <br />Wet Adhesion <br />Spray Polyurethane Foam C794 / D903 Pass 2.0 min <br />A4271 Acrylic BleedTrap Base Coat C794 / D903 Pass 2.0min <br />EPDM C794 / D903 Pass 2.0min <br />PVC C794 / D903 Pass 2.0min <br /> CRRC Rapid <br />SOLAR PERFORMANCE ASTM Test Initial Rating (Lab-Aged) <br />Solar Reflectance C1549 0.87 0.81 <br />Thermal Emittance C1371 0.89 0.88 <br />CEMENTS AND COATINGS FOR ROOFING SYSTEMS <br />CLASSIFIED BY UNDERWRITERS LABORATORIES INC. <br />AS TO AN EXTERNAL FIRE EXPOSURE ONLY 60PO <br />DESCRIPTION GacoFlex S42 Series coatings are high adhesion, solvent-free, single-component waterproof elastomeric moisture-curing silicone coatings. <br />USAGE <br />GacoFlex S42 Series may be used as a maintenance coating system over pre-existing elastomeric roof coatings, metal roofs, APP*, SBS*, BUR*, and <br />weathered single ply membranes (EPDM, PVC, Hypalon®, and TPO/CPA) on a roofing substrate where the membrane surface is in sound condition, but requires a renewal of the membrane surface due to the normal effect of aging and use. <br />A roof coated with GacoFlex S42 Series is ideal for use as part of a rainwater catchment system (NSF certification in process). <br />GacoFlex S42 Series Coatings are suitable liquid applied silicone coatings used in sprayed-in-place polyurethane foam roofing systems. <br />GacoFlex S42 Series Coatings may also be used over concrete and other coatings. GacoFlex S42 may also be used over some asphaltic substrates, <br />such as modified bitumen, when properly applied over an approved base coat, such as with GacoFlex A4271 BleedTrap™ Base Coat; please contact <br />Firestone Building Products for specific recommendations. <br />When properly applied, the coating system helps provide a seamless weather-tight seal that protects the substrate from degradation caused by <br />ultraviolet light, water and other normal weathering hazards. <br />* Please note that a base coat of BleedTrap is required for SBS substrates and recommended for APP and BUR prior to coating with GacoFlex S42. Not to be used over gravel surfaced BUR’s. <br />COLORS S4200 White, S4222 Gray**, S4248 Tan**; S4229 Dark Gray** (custom colors available as special orders only). **colors not to be used over asphalt systems. <br />APPLIED PRODUCT DATA <br />WEATHERABILITY Excellent durability, color stability and chalk resistance. <br />TOXICITY Not for use in contact with edible substances or for long-term storage of potable water. <br />CHEMICAL RESISTANCE Excellent solvent and chemical resistance. <br />PACKAGED PRODUCT DATA <br />THEORETICAL COVERAGE <br />1.25 gallons per 100 sq. ft. to yield approximately 18 dry mils. On granulated and other rough surfaces, apply one coat at the rate of 1.75 gallons per <br />100 square feet. NOTE: Application rate is job specific and losses due to overspray, surface profile, and wind may occur. Additional material may be <br />required to achieve dry film thickness. <br />SOLIDS Weight: 96% (ASTM D1644) / Volume: 95% (ASTMD2697) <br />VOC <50 g/l (<0.417 lb/gal) <br />FLASH POINT ASTM D3278 178°F (81°C) <br />STORAGE STABILITY Two years from date of manufacture when stored in sealed containers between 0°F - 80°F (-17°C - 26°C). <br />APPLICATION <br />MIXING Mix before application to ensure uniform color and consistency. <br />THINNING Thinning is not recommended under normal conditions. <br />ASPHALT ROOFING <br />SEALER <br />To help inhibit bleed-through on asphaltic and bitumen-containing substrates, first apply 1 coat of GacoFlex A4271 BleedTrap Base Coat for Asphalt <br />Roofing at a rate of 100 sq. ft. per gallon to yield 6 dry mils. <br />PRIMER When GacoFlex E5320 2-Part Epoxy Primer/Filler is necessary, such as on some single ply membranes, priming should be done in accordance with label directions. An anti-corrosive metal primer may be used on ferrous metal roofs to help prevent corrosion. <br />APPLICATION <br />Apply by brush or ¾” nap woven roller as received. For spray application, use as received; consult Gaco Western’s Silicone Spray Guide SG-Silicone for more <br />information. For cold weather application, keep material stored above 65°F (18°C). Do not apply if rain is expected within 1 hour. For application in temperatures below freezing or above 120°F (49°C), contact Firestone Building Products. On smooth surfaces, apply one coat at the rate of 1.25 gallons per 100 square feet to <br />achieve approximately 18 dry mils. On granulated and other rough surfaces, apply one coat at the rate of 1.75 gallons per 100 square feet. Coat all surfaces including <br />expansion joint covers and flashings. Extra material is required at all edges and penetrations. NOTE: Application rate is job-specific and losses due to overspray, surface profile and wind may occur. Additional material may be required to achieve 18 dry mils. <br />DRY TIME Final coat should be allowed to cure 24 to 48 hours, depending on temperature and humidity, before suitable for light foot traffic. <br />MKGF0 818 © 2018 Firestone Building Products Company, LLC <br />GacoFlex S42 Series <br />gaco.com | 800 456 4226Gaco is a Firestone Building Products brand. <br />CLEAN UP Clean application tools and equipment with GacoFlex™ Silicone Solvent. Recirculate through lines and gun until residual coating is removed. DO NOT USE WATER OR RECLAIMED SOLVENTS. <br />For specific Safety and Health information please refer to Safety Data Sheet. <br />High Adhesion 100% Silicone Coating <br />Solar Reflectance Index (SRI) E1980 110 101