My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
830 North Michigan Street_AA 2026-0715
sbend
>
Public
>
Historic Preservation
>
2026
>
August
>
Administrative Approvals
>
830 North Michigan Street_AA 2026-0715
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2026 8:33:35 AM
Creation date
7/21/2026 8:33:12 AM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
830 North MIchigan Street
HPC Document Type
Certification
HPC Local Landmark
i. South Bend
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
July 2, 2026 <br />Mr. Rolf Seh <br />City of South Bend, Division of Engineering - Department of Public Works <br />215 South Dr. Martin Luther King Jr. Boulevard, Suite 400 <br />South Bend, Indiana 46601 <br />Re: North Pumping Station Suction Well Assessment <br />830 North Michigan Street <br /> South Bend, Indiana 46601 <br />Project No. 202602038 <br />Dear Mr. Seh: <br />At your request, Mr. Benjamin J. Hinman, PE, of American Structurepoint, Inc., performed an <br />investigation at the above-referenced property on June 23, 2026, and has prepared this summary <br />report. The purpose of the investigation was to assess the brick suction well behind the North <br />Pumping Station and determine if the structure has reached the end of its useful life. Weather <br />conditions were mostly sunny and approximately 77 degrees Fahrenheit during the investigation. <br />BACKGROUND <br />The North Pumping Station was constructed in 1912. It is presumed that the suction well was <br />constructed at the same time. <br />We understand that the subject suction well is no longer used, however, due to its location within <br />the historical Leeper Park, a structural assessment is required to determine whether the structure <br />should be razed. The brick suction well was superseded by active wells 1B, 2A, 3A, and 5A, <br />which were installed between 2001 and 2019, and were also located on the grounds of Leeper <br />Park near the pumping station. <br />During this investigation it was requested that the interior of the suction well be opened for <br />viewing, but employees of the north pumping station no longer had keys to open the well. The <br />well was therefore inspected solely from the outside. <br />OBSERVATIONS <br />For reference purposes in this report, the subject suction well is located east of the North Pumping <br />Station. The following observations were made regarding the subject property:
The URL can be used to link to this page
Your browser does not support the video tag.