805 Arch AvenueAddress:01 - Lead HazardsUnit: <br />Room 10 - HallwayLocation:0Approx. Wall SF: 0Ceiling/Floor SF:9 - <br />Spec Quantity Units Unit Price Total PriceSpec # <br />Trade: 9 Environmental Rehab <br />LBPSCPI 9.00 SFSCRAPE AND PAINT - INTERIOR ________________ <br />After establishing any required floor containment with <br />polyethylene sheeting, mist defective paint area with water to <br />the point of saturation. <br />Repair substrate as necessary to ensure proper adhesion and <br />performance and aggressively scrape all loose paint with a <br />scraper. Feather edges with a wet, 100-grit, sponge sanding <br />block. Detergent wash, rinse, allow to dry, and HEPA vacuum <br />all visible chips. Prime, caulk seams and top coat with premium <br />acrylic latex per manufacturer's instructions. <br />Components contain deteriorated lead-based paint. <br />Containment Required per 24 CFR 35.1345. <br />Door Casing - To Room 12 <br />Trade: 219 Lead Abatement <br />LBPD05 4.00 EAINT-DOOR - HISTORIC ________________ <br />Remove, package, dispose of door components as listed, <br />replace with like door components. Install all necessary door <br />hardware. Door finish to be similar to that of existing door. All <br />work to be completed following lead safe work practices and <br />applicable lead abatement regulations. <br />Door Casing and Jamb - To Rooms 11, 14, Closet <br />Door Jamb - To Room 13 <br />Location Total:____________ <br />Page 12 of 27