Green Tech/Republic Services <br /> • 329 IAC 11-13.5-14(a)(1):All facility floors and the loading bay tunnel must be maintained so as to <br /> prevent standing water within the facility structure.Alt drainage and liquids originating from: (A) <br /> storage, handling, and processing MSW; (B)cleaning floors; or(C)washout water from a MSW <br /> vehicle; must be properly directed to a sanitary sewer, a holding tank constructed and operated in <br /> accordance with any applicable local approvals, or the equivalent of a sanitary sewer or holding <br /> tank. <br /> • Violation Details: At the time of inspection on March 12, 2025, erosion of the tipping floor had <br /> resulted in large depressions which exposed rebar in multiple areas. In addition, a large hole had <br /> developed in the east end of the tipping floor.Water and waste had become trapped in this hole. <br /> • Status Update October 10, 2025:At the time of inspection, the previously documented hole in the <br /> tipping floor and exposed rebar were observed. Mr. Havemann provided receipts for concrete <br /> used to attempt a repair on April 18, 2025, and a photo of the temporary repair to the tipping floor <br /> was provided via text message on October 15, 2025. However,the April 18, 2025, repair was <br /> unsuccessful. A quote to cut out and replace the damaged section of the floor has been obtained, <br /> but the work is not yet contracted.A second attempt to temporarily repair the hole in the tipping <br /> floor has been contracted, but a date for the repair has not been established. <br /> • Status Update January 14, 2026:At the time of inspection,the hole in the tipping floor was being <br /> filled with sand and rock daily to create a workable surface. Mr. Havemann stated that the <br /> company has decided to resurface the entire tipping floor and have the work done by a company <br /> based in DeMotte, IN. However,the project has not been scheduled. <br /> • Required Action:The damaged areas of the tipping floor must be repaired. <br /> • NOTE: it seems like they are working towards resolving the issue, but it hasn't been scheduled <br /> Thanks! <br /> Allison Doctor <br /> cProject Manager <br /> Environmental&Brownfields <br /> ,: Department of Community Investment <br /> {; 215 S Dr.Martin Luther King Jr.Blvd <br /> /f Suite 500 <br /> South Bend,IN 46601 <br /> .. (574)235-9337 <br /> (www.southbendin.gov]www.southbendin.gov <br /> We deliver services that empower everyone to thrive. <br /> Excellence I Accountability I Innovation I Inclusion I Empowerment <br /> From: Michelle Adams<madams@southbendin.gov> <br /> Sent:Thursday,January 29, 2026 8:07 AM <br /> To:Allison Doctor<adoctor@southbendin.gov> <br /> Subject: RE:Scrap Metal Dealers <br /> Good morning Allison, <br /> 2 <br />