Pass 1030.7-Emergency escape and rescue openings <br /> Required emergency escape and rescue openings shall be <br /> maintained in accordance with the code in effect at the time <br /> of construction,and the following:Required emergency <br /> escape and rescue openings shall be operational from the <br /> inside of the room without the use of keys or tools.Bars. <br /> grilles.grates or similar devices are allowed to be placed over <br /> emergency escape and rescue openings provided the <br /> minimum net clear opening size complies with the code that <br /> was in effect at the time of construction and such devices <br /> shall be releasable or removable from the inside without the <br /> use of a key.tool or force greater than that which is required <br /> for normal operation of the emergency escape and rescue <br /> opening. <br /> Pass 1030.8*-Testing&maintenance <br /> All two-way communication systems for areas of refuge shall <br /> be inspected and tested on a yearly basis to verify that all <br /> components are operational.When necessary.the tests shall <br /> be conducted in the presence of the fire code official. <br /> Pass 1030.9-Floor identification signs <br /> %) The floor identification signs required by Sections 1022.9 and <br /> 110423 shall be maintained in an approved manner. <br /> Pass 1104.18-Exit access travel distance <br /> Exits shall be located so that the maximum length of exit <br /> access travel.measured from the most remote point to an <br /> approved exit along the natural and unobstructed path of <br /> egress travel,does not exceed the distances given in Table <br /> 1104.17.2. <br /> Pass 1104.19-Common path of egress travel <br /> The common path of egress travel shall not exceed the <br /> distances given in Table 1104.17.2. <br /> Pass 1104.23-Stairway floor number signs <br /> Existing stairs shall be marked in accordance with Section <br /> 1022.9 <br /> Pass 1104.3-Exit sign illumination <br /> Exit signs shall be internally or externally illuminated.The <br /> face of an exit sign illuminated from an external source shall <br /> have an intensity of not less than S footcandles(54 lux). <br /> Internally illuminated signs shall provide equivalent <br /> luminance and be listed for the purpose.Exception:Approved <br /> self-luminous signs that provide evenly illuminated letters <br /> shall have a minimum luminance of 0.06 foot-lamberts(0.21 <br /> cdlm2). <br /> Pass 1104.4-Power source <br /> Where emergency illumination is required in Section 1104.5. <br /> exit signs shall be visible under emergency illumination <br /> conditions.Exception:Approved signs that provide <br /> continuous illumination independent of external power <br /> sources are not required to be connected to an emergency <br /> electrical system. <br /> GENERATED ON 3/17/26, 10:39 AM : OF 10 <br />