Laserfiche WebLink
TEST REPORT FOR CASCADE ENGINEERING <br />Date: Nov-14-2022 <br />Report No.: 104730379GRR-001 <br />P.O.: 16646 <br />DURABILITY DURING PULLING TEST C: <br />Date Tested: Jun-29-2021— Oct-12-2022 <br />Location Tested: Cascade Engineering <br />Grand Rapids, MI <br />DESCRIPTION OF SAMPLES: <br />Part Description: <br />Condition of Samples: <br />Seven (7) Samples <br />New <br />TESTING SAMPLES: <br />96 Gallon - Sterling <br />64 Gallon - Icon <br />96 Gallon - Icon <br />35 Gallon - Icon <br />96 Gallon - Automated <br />32 Gallon - Sterling <br />64 Gallon - Sterling <br />TEST PROCEDURE: ANSI Z 245.30-2018 CONTAINERS STANDARD DIMENSIONS <br />Test Method: Pull cart by handles off of curb fully loaded. <br />Pull cart by handles up curb unloaded. <br />Curb Height: 14 cm (5 1/2") <br />Curb Radii: 26 mm (1") <br />Temperature in Test Area: 73°F ± 9°F <br />Number of Cycles: 520 <br />ACCEPTANCE CRITERIA: <br />Handles, wheels, axles, their attachments to the container, and the container itself must <br />remain functional. <br />RESULTS: <br />SAMPLE ID <br />PULL CART ON/OFF CURB BY HANDLES <br />CYCLES <br />LOAD (LBS) <br />RESULTS <br />96 Gallon - Sterling <br />520 <br />336.5 <br />Pass <br />96 Gallon - Icon <br />520 <br />336.5 <br />Pass <br />96 Gallon - Automated <br />520 <br />337.5 <br />Pass <br />64 Gallon - Sterling <br />520 <br />251 <br />Pass <br />64 Gallon - Icon <br />520 <br />251 <br />Pass <br />35 Gallon - Icon <br />520 <br />133 <br />Pass <br />32 Gallon -Sterling <br />520 <br />115 <br />Pass <br />The submitted samples meets the acceptance level criteria. <br />Version (18-Apr-2017) Page 7 of 11 GFT-OP-10b <br />