SUBMITTAL INFORMATION <br />Corporation Stops - (F1000-x-NL style) <br />AWWA/CC TAPER THREAD INLET BY PACK JOINT FOR COPPER OR PLASTIC TUBING (CTS) OUTLET <br />Solid one piece tee -head and key <br />AWWA/CC Taper Thread <br />Inlet <br />Body Outlet Threads Beveled EPDM rubber gasket <br />provides hydraulic seal <br />-..."v. <br />Length <br />Anti -friction washer <br />Integral clamp contains <br />machined grooves for <br />axial restraint <br />Pack Joint Nut <br />— Outlet — <br />Stainless steel screw <br />activates clamp <br />VALVE SIZE <br />INLET SIZE <br />OUTLET <br />SIZE <br />VALVE <br />LENGTH <br />BODY OUTLET <br />THREADS <br />APPROX. <br />WT. LBS <br />PART <br />NUMBER <br />✓ SUBMITTED <br />ITEM(S) <br />1/2" <br />1/2" <br />1/2" <br />2-15/16" <br />1/2" Flare Copper <br />.5 <br />F1000-1-NL <br />5/8" <br />5/8" <br />5/8" <br />3-7/16" <br />5/8" Flare Copper <br />1.0 <br />F1000-2-NL <br />5/8" <br />5/8" <br />3/4" <br />3-1/2" <br />3/4" Flare Copper <br />1.4 <br />F1000-23-NL <br />3/4" <br />3/4" <br />3/4" <br />3-3/4" <br />3/4" Flare Copper <br />1.7 <br />F1000-3-NIL <br />3/4" <br />3/4" <br />1" <br />3-7/8" <br />V Flare Copper <br />1.9 <br />F1000-34-NL <br />1" <br />1" <br />1" <br />4-9/16" <br />1" Flare Copper <br />2.7 <br />F1000-4-NL <br />1" <br />1" <br />1-1/4" <br />4-5/8" <br />1 1-1/4" Flare Copper <br />3.2 <br />F1000-45-NL <br />Note: Ford recommends using insert stiffeners with plastic pipe or tubing. <br />FEATURES <br />• All brass that comes in contact with potable water conforms to AWWA Standard C800 <br />(ASTM B584, UNS C89833) <br />• The product has the letters "NIL" cast into the main body for lead-free identification <br />• Certified to NSF/ANSI Standard 61 and NSF/ANSI Standard 372 where applicable <br />• Brass components that do not come in contact with potable water conform to AWWA <br />Standard C800 (ASTM B62 and ASTM B584, UNS C83600, 85-5-5-5) <br />• Body design provides larger, more rugged wrench flats for proper installation. <br />• Meets 100 PSI working pressure requirement of AWWA Standard C800. <br />The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, <br />including specifications, are subject to change without notice. Please verify that your product information is current. <br />The Ford Meter Box Company, Inc. Submitted By: <br />I I I P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 <br />Phone:260-563-3171 / Fax:800-826-3487 <br />Overseas Fax: 260-563-0167 <br />www.fordmeterbox.com 05/15/17 <br />