Laserfiche WebLink
DIMENSIONS AND WEIGHTS FOR SPECIAL CLASSES <br />OF PUSH -ON DUCTILE IRON PIPE <br />P:PE <br />SZE <br />3 <br />NOMINAL <br />THICKNE THICKNESS OD- <br />1 52 0.28 3.96 <br />WT. OF <br />BARREL <br />PER FT. t <br />9.9 <br />TVTON' <br />WT. OF <br />7 <br />JOINT <br />AVG. WT. <br />WT. PER PER FT.t <br />185 <br />10.3 <br />3 <br />54rO, <br />0.34 3.96 <br />11.8 <br />7 <br />220 <br />12.2 <br />3 <br />5640 <br />3.96 <br />13.7 <br />7 <br />255 <br />14.1 <br />4 <br />51 <br />0.26 4.80 <br />11.3 <br />9 <br />210 <br />11.8 <br />4 <br />520.29 <br />4.80 <br />12.6 <br />9 <br />23S <br />13.1 <br />4 <br />530.32 <br />4.80 <br />13.8 <br />9 <br />255 <br />14.3 <br />4 <br />540.35 <br />4.60 <br />15 <br />9 <br />280 <br />15.5 <br />4 <br />550.38 <br />4.80 <br />16.1 <br />9 <br />300 <br />16.7 <br />4 <br />56 <br />1 0.41 4.80 <br />1 17.3 <br />9 <br />320 <br />17.8 <br />6 <br />50 <br />1 0.25 6.90 <br />1 16 <br />11 <br />300 <br />16.6 <br />6 <br />51 <br />1 0.28 6.90 <br />17.8 <br />11 <br />330 <br />18.4 <br />6 <br />52 <br />0.31 6.90 <br />19.6 <br />11 <br />365 <br />20.2 <br />6 <br />53 <br />0.34 6.90 <br />21.4 <br />11 <br />395 <br />22.0 <br />6 <br />54 <br />0.37 6.90 <br />23.2 <br />11 <br />430 <br />23.8 <br />6 <br />55 <br />0.40 6.90 <br />25 <br />11 <br />460 <br />2S.6 <br />6 <br />56 <br />0.43 6.90 <br />26.7 <br />11 <br />490 <br />27.3 <br />8 <br />50 <br />0.27 9.05 <br />22.8 <br />17 <br />425 <br />23.7 <br />8 <br />51 <br />0.30 9.05 <br />25.2 <br />17 <br />470 <br />26.1 <br />8 <br />52 <br />0.33 9.05 <br />1 27.7 <br />17 <br />515 <br />28.6 <br />8 <br />53 <br />0.36 9.05 <br />1 30.1 <br />17 <br />560 <br />31.0 <br />8 <br />54 <br />0.39 9.05 <br />32.5 <br />17 <br />600 <br />33.4 <br />8 <br />55 <br />0.42 9.05 <br />34.8 <br />17 <br />645 <br />35.7 <br />8 <br />56 <br />0.45 9.05 <br />37.2 <br />17 <br />685 <br />38.1 <br />10 <br />50 <br />0.29 11.10 <br />30.1 <br />24 <br />565 <br />31.4 <br />10 <br />51 <br />0.32 11.10 <br />33.2 <br />24 <br />1 620 <br />34.5 <br />10 <br />52 <br />0.35 11.10 <br />36.2 <br />24 <br />675 <br />37.5 <br />10 <br />53 <br />0.38 11.10 <br />39.2 <br />24 <br />730 <br />40.5 <br />10 1 <br />54 1 <br />0.41 11.10 1 <br />42.1 <br />24 <br />780 <br />43.4 <br />10 <br />55 <br />0.44 11.10 <br />45.1 <br />24 <br />835 <br />46.4 <br />10 <br />56 <br />0.47 11.10 <br />48 <br />24 <br />890 <br />49.3 <br />12 <br />50 <br />0.31 13,20 <br />38.4 <br />29 <br />720 <br />40.0 <br />12 <br />51 <br />0.34 13.20 <br />42 <br />29 <br />785 <br />43.6 <br />12 <br />52 <br />0.37 13.20 <br />45.6 <br />29 <br />850 <br />47.2 <br />12 <br />53 <br />0.40 13.20 <br />49.2 <br />29 <br />915 <br />50.8 <br />12 <br />54 <br />0.43 13.20 <br />52.8 <br />29 1 <br />980 <br />54A <br />12 <br />55 <br />0.46 13.20 <br />56.3 <br />29 1 <br />1040 <br />57.9 <br />12 <br />56 <br />0.49 113.201 <br />59.9 1 <br />29 1 <br />1105 <br />61.5 <br />STANDARD DIMENSIONS AND WEIGHTS OF <br />3" THROUGH 12" PUSH -ON JOINT DUCTILE IRON PIPE <br />PIPE <br />512E <br />IN. <br />PRESSURE <br />CLASS <br />PSI <br />NOMINAL <br />THICKNESS <br />IN. <br />OD' <br />IN. <br />WT. OF <br />BARREL <br />PER FT. <br />' I.S. <br />TYTON' <br />WT. OF <br />BELL LB. <br />JOINT <br />WT, PER <br />LGTH.* <br />LB. <br />AVG. WT. <br />PER FT3 <br />LB. <br />* Including bell; calculated weight of pipe rounded off to the nearest 5 lb. <br />t Including bell; average weight per foot, based on calculated weight of pipe <br />before rounding. <br />* Tolerances of OD of spigot end: 3 -12 in. = +0.06 in. & -0.06 in. <br />`* Fastite'e Joint <br />STANDARDS APPLICABLE TO DUCTILE IRON PIPE AND FITTINGS <br />THICKNESS DESIGN OF DUCTILE IRON PIPE <br />ANSI/AWWA C150/A21.50 <br />DUCTILE IRON PIPE FOR WATER AND OTHER LIQUIDS <br />AN51/AWWA C151/A21.51, FEDERAL WWP421D, GRADE C <br />DUCTILE IRON PIPE FOR GRAVITY FLOW SERVICE <br />AN51/ASTM A746 <br />DUCTILE IRON FITTINGS FORWATERAND OTHER LIQUIDS. (3 in. through 36 in.) <br />:ANSI/AWWA C110/A21.10 <br />DUCTILE IRON COMPACT FITTINGS (3 in. through 24 in.) <br />ANSI/AWWA C153/A21.53 <br />FLANGED FITTINGS <br />ANSI/AWWA ClIO/A21.10, ANSI B16.1 <br />DUCTILE IRON PIPE WITH THREADED FLANGES <br />ANSI/AWWA C115/21.15 <br />COATINGS AND LININGS <br />Asphaltic <br />ANSI/AWWA C151/A21.51, ANSI/AWWA C710/A21.10, ANSI/AWWA C153/A21.53 <br />Cement Lining <br />ANSI/AWWA C104/A21.4 <br />Various Epoxy Linings and Coatings <br />MANUFACTURER'S STANDARD <br />Exterior Polyethylene Encasement <br />ANSI/AWWA C105/A21.5 <br />JOINTS - PIPE AND FITTINGS <br />Push -On and Mechanical Rubber -Gasket Joints <br />ANSI/AWWA C111/A21.11, FEDERAL WWP421D <br />Flanged <br />ANSI/AWWA C115/A21.15, ANSI 616.1 <br />_Grooved and Shouldered <br />ANSI/AWWA C606 <br />PIPE TMREAD5 <br />ANSI B2.1 <br />INSTALLATION <br />ANSI/AWWA C600 <br />TytonO and Tyton Joint® are registered trademarks of US Pipe and Foundry. <br />isPOCKET ENGINEER <br />Available for iOS + Android ® ® a <br />or online at pe.mmanexom CONNECT WITH US ON 91 <br />NEW JERSEY <br />OHIO <br />UTAH <br />CANADA <br />185 Sitgreaves St. <br />2266 S. 6th St. <br />1401 E. 2000 South <br />Suite 1, 55.Frid Street, <br />MCWANE <br />DUCTILE <br />Phillipsburg, NJ 08865 <br />908-454-1161 <br />Coshocton, OH 43812 <br />740-622-6651 <br />Provo, UT 84606 <br />801-373-6910 <br />CANADA <br />PIPE <br />Hamilton, Ontario, Canada <br />L8P4M3 <br />mcwaneductile.com <br />canadapipe.com <br />