My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
620 W Washington Street_AA 2025-0618a
sbend
>
Public
>
Historic Preservation
>
2025
>
July
>
Administrative Approvals
>
620 W Washington Street_AA 2025-0618a
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/25/2025 10:20:13 AM
Creation date
6/25/2025 10:05:57 AM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
620 West Washington Street
HPC Document Type
Certification
HPC Local Landmark
i. South Bend
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SURFACE PREPARATION <br />MAKE SURE SURFACE IS PROPERLY ABRADED, <br />CLEAN, AND DRY BEFORE APPLICATION. SURFACE <br />MUST BE FREE OF DIRT, GREASE, OIL, AND OTHER <br />CONTAMINANTS. CONTAMINANTS COULD LEAD TO <br />SURFACE DEFECTS SUCH AS CRAWLING AND POOR <br />ADHESION. <br />ALL CRACKS SHOULD BE GROUND OUT WITH A <br />VBLADE AND ALL DUST AND DEBRIS REMOVED. IT <br />MAY BE NECESSARY TO USE A WIRE BRUSH TO <br />ENSURE CRACKS AND VOIDS ARE PROPERLY <br />PREPARED. <br />ENSURE THAT THE FLOOR TEMPERATURE IS MORE <br />THAN 5 DEGREES OVER THE LOCAL DEW POINT TO <br />AVOID WATER CONDENSATION. <br />FLOOR MOISTURE SHOULD BE MONITORED WITH A <br />NONDESTRUCTIVE ELECTRONIC MOISTURE METER <br />AS PER ASTM F2659. READING SHOULD BE LOWER <br />THAN 5.5% BY THIS METHOD. <br />PREMIX REQUIREMENTS <br />MENDER X2: <br />PART A: REMOVE LID AND MIX WITH DRILL MIXER <br />FOR 2 MINUTES. BE SURE TO SCRAPE THE BOTTOM <br />OF THE BUCKET TO MIX IN ANYTHING THAT HAS <br />SETTLED OUT. <br />PART B: NOT REQUIRED. <br />MENDER X2NC: <br />PART A: INVERT AND SHAKE VIGOROUSLY FOR <br />ABOUT 1 MINUTE. CHECK THAT THERE ARE NOT <br />SOLIDS ON THE BOTTOM OF THE JUG, CONTINUE <br />SHAKING AND INVERTING UNTIL UNIFORM. <br />PART B: NOT REQUIRED. <br />MIX RATIO: <br />1:1 MIX RATIO BY VOLUME A:B <br />+1 PART SAND BY VOLUME OR MORE IF DESIRED <br />MIX INSTRUCTIONS: <br />CAREFULLY MEASURE 1 PART A AND 1 PART B BY <br />VOLUME AND BLEND TOGETHER FOR 2 MINUTES <br />WITH A DRILL MIXER. MIX IN THE DESIRED AMOUNT <br />OF SAND. EITHER 4030 OR 5030 GRADE SAND WILL <br />WORK. PROCEED TO APPLICATION IMMEDIATELY <br />AFTER MIXING. <br />NOTE THAT LARGER VOLUME MIXES WILL HAVE A <br />SHORTER POT LIFE DUE TO THE HEAT GENERATION <br />OF THE MATERIAL. <br />MIX IN SMALL BATCHES AS NEEDED. DO NOT MIX <br />MORE MATERIAL THAN CAN BE USED IN 510 <br />MINUTES. <br /> APPLICATION <br />1. POUR MIXTURE INTO PRE PREPARED <br /> CRACKS, PITS, AND SPALLS IN THE CONCRETE. <br />2. AFTER 20 MINUTES, CHECK THAT THE MENDER X2 <br /> IS HARD ENOUGH TO GRIND. IF NOT, CHECK IN 10 <br /> MORE MINUTES. TEMPERATURE AND HUMIDITY <br /> CONDITIONS WILL AFFECT THE HARDNESS <br /> DEVELOPMENT. <br />3. GRIND MATERIAL FLUSH WITH THE SURFACE OF <br /> THE CONCRETE. SWEEP AND VACUUM AWAY ANY <br /> LEFTOVER DUST AND DEBRIS. INSPECT REPAIRS <br /> AND PERFORM TOUCH UPS AS NEEDED. <br />4. FOR A GRIND AND CLEAR FLOOR, USE MENDER <br /> X2NC WITH CLEAN CONCRETE DUST <br /> EXAMPLE: FROM FLOOR GRINDER TO MATCH <br /> CONCRETE APPEARANCE. <br />PRODUCT AND APPLICATION SUPPORT <br />REFER TO THE PENNTEK TRAINING MANUAL OR <br />CONTACT TECHNICAL SUPPORT LINE <br />9524910616 FOR FURTHER INFORMATION. <br />Tech Support 952-491-0616 (Call/Text) <br />techsupport@penntekcoating.com <br />7850 Lakeville BLVD, Lakeville, MN 55044 <br />Penntek.com <br />MENDER X2 AND X2-NC <br />T E CHN I C AL D ATA SHEE T <br />Page 2
The URL can be used to link to this page
Your browser does not support the video tag.