My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
25-20 Resolution to Approve the Issuance of Scrap Metal / Junk Dealers / Recycling Operation Licenses
sbend
>
Public
>
Common Council
>
Legislation
>
Upcoming Bills
>
2025
>
04-14-2025
>
25-20 Resolution to Approve the Issuance of Scrap Metal / Junk Dealers / Recycling Operation Licenses
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2025 1:24:34 PM
Creation date
4/1/2025 1:23:56 PM
Metadata
Fields
Template:
City Council - City Clerk
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
STATUS CODE DESCRIPTION <br /> RESOLVED 906.2-General requirements Portable fire extinguishers shall be selected, installed and maintained in <br /> accordance with this section and NFPA 10. Exceptions: 1.The travel distance to <br /> reach an extinguisher shall not apply to the spectator seating portions of Group <br /> A-S occupancies.2. Thirty-day inspections shall not be required and maintenance <br /> shall be allowed to be once every three years for dry-chemical or halogenated <br /> agent portable fire extinguishers that are supervised by a listed and approved <br /> electronic monitoring device, provided that all of the following conditions are <br /> met:2 1. Electronic monitoring shall confirm that extinguishers are properly <br /> positioned, properly charged and unobstructed.2.2.Loss of power or circuit <br /> continuity to the electronic monitoring device shall initiate a trouble signal.2.3. <br /> The extinguishers shall be installed inside of a building or cabinet in a <br /> noncorrosive environment.2.4.Electronic monitoring devices and supervisory <br /> circuits shall be tested every three years when extinguisher maintenance is <br /> performed.2.5.A written log of required hydrostatic test dates for extinguishers <br /> shall be maintained by the owner to verify that hydrostatic tests are conducted at <br /> the frequency required by NFPA 10.3. In Group 1-3,portable fire extinguishers <br /> shall be permitted to be located at staff locations. <br /> Inspector: -Comments:Get fire extinguishers tagged up to date tl;;•c•.ighout <br /> building <br /> Location:Not Provided <br /> Resolution Comments:None <br /> Resolution Date:01./21/2025 <br /> NUT IN$AKVION MIT <br /> 01/21/2026 <br /> CONTACT SI/NATUI <br /> Daltongn Won:01/roved 25 @ 13:4 <br /> Signed on:01/21/2025 @ 13:49 <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.