My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2025
>
Opening of Quotations/Proposals/Qualifications
>
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 4:25:16 PM
Creation date
2/11/2025 1:57:02 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
2/11/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
us <br />classified by <br />Underwriters Laboratories, Inc. <br />to UL 1479 and CANIULC-S115 <br />System No. W-L-5027 <br />ANSI/UL1479 (ASTM E814) CAN/ULC S115 <br />F Rating — 2 Hr <br />T Rating —1/2 Hr <br />L Rating At Ambient — Less Than 1 CFM/sq ft <br />L Rating At 400 F — Less Than 1 CFM/sq ft <br />F Rating — 2 Hr <br />FT Rating —112 Hr <br />FH Rating — 2 Hr <br />FTH Rating —1/2 Hr <br />L Rating At Ambient — Less Than 1 CFM/sq ft <br />L Rating At 400 F — Less Than 1 CFM/sq ft <br />SECTION A -A <br />1. Wall Assembly — The fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the <br />individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following <br />construction features: <br />A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) <br />lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. <br />B. Gypsum Board* — Two layers of 5/8 in. (16 mm) thick gypsum wallboard, as specified in the individual Wall and Partition Design. Max diam <br />of opening is 6 in. (152 mm). <br />2. Metallic Sleeve — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 (or thinner) steel pipe cast into wall assembly with joint compound and <br />installed flush with wall surfaces. <br />Reproduced by HILTI,.Inc. Courtesy of <br />Underwriters Laboratories, Inc. <br />Hilt! Firestop Systems January27, 2015 <br />rl— <br />N <br />O <br />to <br />1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.