Laserfiche WebLink
PAD100-DIM <br />DUAL INPUT MODULE <br />Features <br />• Single module with dual contact monitoring inputs <br />• Two (2) Class B or one (1) Class A monitoring inputs <br />SLC Class A, Class X & Class B <br />• Mounts in a standard 4" or double gang box <br />• Wiring terminals accessible when mounted in box <br />• All wiring terminals accept 22 to 12 AWG <br />NOTE: This addressable module does not support 2-wire <br />smoke detectors. <br />Specifications <br />0 Operating Voltage: 24.OV <br />Max SLC Standby Current: 240pA <br />Max SLC Alarm Current: 240pA <br />Max Wiring Resistance of IDC: 100 0 <br />uO�� Max Wiring Capacitance of IDC: 1 pF <br />EOL Resistor: 5.1 K 0 <br />Operating Temperature Range: 32 to 120OF (0 to 49°C) <br />P/N 97663 Operating Humidity Range: 0 to 93% (non -condensing) <br />Max no. of Module Per Loop: 127 units <br />Dimensions: 4.17" x 4.17" x 1.14" (106 mm x 106 mm 29 mm) <br />Mounting Options: Standard 4" Square or Double Gang Box <br />Description Shipping Weight: 0.6 Ibs <br />The PAD100-DIM uses one (1) SLC loop address when monitoring two (2) Class B circuits or one (1) <br />Class A circuit. The module mounts on either a 4" square or double gang box. The module is capable <br />of monitoring two (2) separate class B circuits making it ideal for monitoring sprinkler waterflow and <br />valve tamper switches when they are located in the same proximity. The PAD100-DIM includes one <br />red LED to indicate the module's status. In normal condition, the LED flashes when the device is be- <br />ing polled by the control panel. When an input is activated, the LED will flash at a fast rate. <br />Application <br />The PAD100-DIM is compatible with JFS-IP series addressable fire alarm control panels. The <br />PAD100-DIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, <br />valve tamper switches, or conventional pull stations. The module is capable of monitoring two sepa- <br />rate Class B or one Class A circuits. <br />Setting the Address <br />Each addressable SLC device must be assigned an address. The address is set using the DIP switch <br />located on the PAD100-DIM. When the PAD100- DIM is used to monitor two individual Class B cir- <br />cuits a single device address is assigned, each input is then identified as a sub -point of the module <br />address. For example, if the address number is assigned as "8", the first input will be "8.1" and the <br />second input will be "8.2". <br />Before connecting a device to the SLC loop, take the following precautions to prevent potential dam- <br />age to the panel or device: <br />1. Power to the device is removed. <br />2. Field wiring is correctly installed. <br />3. Field wiring has no open or short circuits. <br />DS1336 Revised: 30-Aug-2018 <br />© 2017 Janus Fire Systems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademark of Janus Fire Systems. <br />