Laserfiche WebLink
PAD100-NAC <br />NOTIFICATION APPLIANCE CIRCUIT <br />Features <br />Monitored output module that provides an additional <br />supervised output <br />Can be used as either a NAC or Releasing Output <br />• NAC can be wired Class A or Class B <br />• Monitors presence of 24 VDC Aux Power <br />• SLC Class A, Class X, & Class B <br />- <br />Mounts in a standard 4" or double gang box <br />Wiring terminals accessible when mounted in box <br />All wiring terminals accept 22 to 12 AWG <br />Specifications <br />Operating Voltage: 24.OV <br />Max SLC Standby Current: 200pA <br />Max SLC Alarm Current: 200pA <br />@ Aux Power Required: 16-33 VDC <br />LISTED Output Ratings: 24 VDC, 2A <br />EOL Resistor: 5.1 K 0 <br />P/N 97659 EOL Resistor Diode: EOLR 3005012 (P/N 18712) for <br />Releasing Applications (Must Be Ordered Separately) <br />Operating Temperature Range 32 to 120°F (0 to 49°C) <br />Operating Humidity Range: 0 to 93% (non -condensing) <br />Max no. of Module Per Loop: 127 units <br />Dimensions: 4.17" x 4.17" x 1.14" (106 mm x 106 mm 29 mm) <br />Mounting Options: Standard 4" Square or Double Gang Box <br />Description Shipping Weight: 0.6 Ibs <br />The PAD 100-NAC module uses one (1) address on an SLC Loop. The module provides a program- <br />mable source of power to supervise and control one (1) Class B or Class A Notification Appliance or <br />one (1) Class B Releasing Circuit. The module requires and supervises a 24 VDC auxiliary power <br />connection. The PAD100-NAC includes one red LED to indicate the module's status. In normal condi- <br />tion, the LED flashes when the device is being polled by the control panel. <br />Application <br />The PAD100-NAC is compatible with JFS-IP series addressable fire alarm control panels. The <br />PAD100-NAC is a monitored Notification Appliance Circuit that wires to the SLC loop to provide an <br />additional notification circuit. When used with an addressable releasing panel, the PAD100-NAC can <br />provide an additional releasing circuit. <br />Setting the Address <br />Each addressable SLC device must be assigned an address. The address is set using the DIP switch- <br />es on the PAD100-NAC module. <br />Before connecting a device to the SLC loop, take the following precautions to prevent potential dam- <br />age to the panel or device: <br />1. Power to the device is removed. <br />2. Field wiring is correctly installed. <br />3. Field wiring has no open or short circuits. <br />DS1333 Revised: 23-Jul-2020 <br />© 2017 Janus Fire Systems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademark of Janus Fire Systems. <br />