Laserfiche WebLink
PAD1OO-SIM <br />SINGLE INPUT MODULE <br />Features <br />• One (1) Class B monitoring input <br />• SLC Class A, Class X & Class B <br />Mounts in a standard 4" or double gang box <br />• Wiring terminals accessible when mounted in box <br />• All wiring terminals accept 22 to 12 AWG <br />• NOTE: This addressable module does not support 2-wire <br />smoke detectors. <br />Specifications <br />Operating Voltage: 24.OV <br />+ Max SLC Standby Current: 240pA <br />Max SLC Alarm Current: 240pA <br />Max Wiring Resistance of IDC: 100 0 <br />Max Wiring Capacitance of IDC: 1 pF <br />@ EOL Resistor: 5.1 K 0 <br />LISTED Operating Temperature Range: 32 to 120°F (0 to 49°C) <br />Operating Humidity Range: 0 to 93% (non -condensing) <br />P/N 97662 Max no. of Module Per Loop: 127 units <br />Dimensions: 4.17" x 4.17" x 1.14" (106 mm x 106 mm 29 mm) <br />Mounting Options: Standard 4" Square or Double Gang Box <br />Shipping Weight: 0.6 Ibs <br />Description <br />The PAD100-SIM uses one (1) SLC loop addresses when monitoring one (1) Class B circuit. The <br />module mounts on either a 4" square or double gang box. The module is capable of monitoring one <br />(1) Class B circuit. The PAD100-SIM includes one red LED to indicate the module's status. In normal <br />condition, the LED flashes when the device is being polled by the control panel. When the input is <br />activated, the LED will flash at a fast rate. <br />Application <br />The PAD100-SIM is compatible with JFS-IP series addressable fire alarm control panels. The <br />PAD100-SIM is an interface module used to monitor dry contact devices such as sprinkler waterflow, <br />valve tamper switches, or conventional pull stations. The module is capable of monitoring one Class <br />B circuit. <br />Setting the Address <br />Each addressable SLC device must be assigned an address. The address is set using the DIP switch <br />located on the PAD 1OO-SIM. <br />Before connecting a device to the SLC loop, take the following precautions to prevent potential dam- <br />age to the panel or device: <br />1. Power to the device is removed. <br />2. Field wiring is correctly installed. <br />3. Field wiring has no open or short circuits. <br />DS1330 Revised: 15-Dec-2017 <br />© 2017 Janus Fire Systems. All rights reserved (5/2017) Janus Fire Systems® is a registered trademark of Janus Fire Systems. <br />