My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2025
>
Opening of Quotations/Proposals/Qualifications
>
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 4:25:16 PM
Creation date
2/11/2025 1:57:02 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
2/11/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TRIM COMPONENTS <br />Trim components are required to operate the clean agent cylinder(s). <br />1/2" (15 mm) NPS Female \ <br />Conduit Hub Knurled <br />with 40" (1016 mm) leads Swivel Nut <br />Emergency <br />Release Button <br />Electric Valve Actuator <br />w/ Supervisory Limit Switch' (P/N 20722) <br />The electric valve actuator attaches to the primary cylinder <br />at the valve actuation connection and is utilized to automati- <br />cally open the cylinder valve upon receipt of a signal from the <br />control panel or other source. It operates between 17 and 30 <br />VDC and consumes 500 mA (.5 Amps) at 24 VDC nominal <br />with a maximum supervisory current of 30 mA (0.03 Amps). <br />The electric valve actuator body is steel construction with a <br />brass knurled swivel nut and a stainless steel actuation pin <br />that depresses the valve core when energized. The limit <br />switch contacts are normally closed when the actuator is not <br />installed onto the cylinder valve and open when the actuator <br />is fully installed onto the valve actuation connection at the top <br />of the cylinder valve. <br />Manual Valve Actuator (P/N 17001) <br />An optional manual valve actuator attaches to the top of the <br />electric valve actuator and provides a means to manually <br />open the cylinder valve. The manual valve actuator consists <br />of a brass body, stainless steel actuation pin, and steel safety <br />ring pin. <br />To discharge the primary cylinder manually, the ring pin is re- <br />moved and the emergency release button is depressed forc- <br />ing the pin in the electric valve actuator to depress the valve <br />core of the cylinder valve. All other connected cylinders will <br />be opened pneumatically. <br />MULTI -CYLINDER ARRANGEMENT COMPONENTS <br />Up to 16 cylinders (1 primary and 15 secondary) may be installed in a single arrangement, with a <br />maximum length of 100 ft (30.48 m) of pilot actuation hose or tubing extending from the primary cyl- <br />inder in either direction. Atypical arrangement is shown below. <br />Discharge <br />Variable Size <br />Pilot Actuation <br />Pressure Switch <br />Flex Hose <br />Mid Line Tee <br />(P/N 97428) <br />(P/N Variable) <br />(P/N 18622) <br />Male NPTZ <br />anual <br />Adapter -� <br />Actuator <br />Pneumatic <br />(P/N 18625) <br />17001) <br />Valve Actuator <br />(P/N 17019) <br />1 1/4" (32 mm) +I <br />Manifold <br />Check Valve _ <br />(P/N 18547) <br />Electric <br />Valve Actuator <br />(P/N 20722) <br />Pilot Actuation <br />Adapter <br />(P/N 18624) _ <br />Pilot Actuation <br />Check Valve <br />(P/N 18560) <br />16" Flex Hose <br />(406 mm) <br />(P/N 18648) <br />Discharge Manifold <br />(Provided By Installer) <br />Pilot <br />Male NPT Actuation <br />Adapter End Line Tee <br />(P/N 18625) (P/N 18611) <br />Primary Secondary Secondary Secondary Secondary <br />Cylinder Cylinder Cylinder Cylinder Cylinder <br />Typical Primary and Secondary Cylinder Arrangement <br />Vent Check <br />(P/N 10173) <br />DS1258 Revised: 21-Dec-2023 <br />Page 5 of 10 <br />Effective January 1, 2016, NFPA 2001 requires that the removal of an electric actuator from the agent storage container discharge valve that it <br />controls shall result in an audible and visual indication of system impairment at the system releasing control panel. <br />
The URL can be used to link to this page
Your browser does not support the video tag.