Laserfiche WebLink
ROOF PLAN NOTES <br />KEY NOTE <br />1 <br />ROOF DRAIN AND OVERFLOW DRAIN. <br />2 <br />SOLAR PANELS (ALTERNATE BID ITEM). REFER TO SHEET <br />A-160A <br />3 <br />ROOF LADDER W/ PARAPET PLATFORM <br />4 <br />30" X 30" ROOF HATCH <br />5 <br />5" X 5" BOX GUTTER AND DOWNSPOUT <br />6 <br />TRELLIS STRUCTURE. <br />8 <br />MECHANICAL EQUIPMENT <br />9 <br />METAL COPING <br />10 <br />ROOF WALKWAY PADS <br />11 <br />30" X 30" ROOF HATCH WITH SAFETY RAILING. <br />12 <br />COLUMNS TO PROTRUDE THROUGH ROOF. WRAP ROOF <br />MEMBRANE UP FACE OF COLUMN MINIMUM 8.11 <br />13 <br />STAIR AND RAILING <br />GENERAL ROOF PLAN NOTES <br />A. TAPERED INSULATION SHALL BE INSTALLED TO ACHIEVE POSITIVE DRAINAGE WITH A <br />MINIMUM RESULTANT SLOPE OF 1/4" PER FOOT EXCEPT FOR ROOF CRICKETS AT THE <br />ROOF DRAINS. <br />B. LOW SLOPE ROOF AREAS SHALL HAVE A MINIMUM OF 4" RIGID INSULATION OVER <br />METAL DECK ROOF DECK. SADDLES, CRICKETS, AND SLOPE PORTIONS OF FLAT ROOF <br />DECK SHALL BE FORMED BY TAPERED INSULATION. AREAS WHERE TAPERED <br />INSULATION IS ANTICIPATED HAVE BEEN INDICATED, BUT SHALL NOT BE CONSIDERED <br />ALL INCLUSIVE. IT IS CONTRACTOR'S RESPONSIBILITY TO PROVIDE SLOPED SURFACES <br />TO ACHIEVE PROPER DRAINAGE. <br />C. ROOF PENETRATIONS AND EQUIPMENT SHOWN SHALL NOT BE CONSIDERED ALL <br />INCLUSIVE. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL <br />DOCUMENTS TO CONFIRM PENETRATIONS AND EQUIPMENT LOCATIONS. FLASH ALL <br />ROOF PENETRATIONS IN ACCORDANCE WITH ROOFING MANUFACTURER'S <br />RECOMMENDATIONS. PROVIDE CRICKETS TO ALLOW FOR PROPER DRAINAGE <br />AROUND UNITS. <br />D. ROOF WALKWAY PADS OR BLOCKS SHALL BE INSTALLED IN ACCORDANCE WITH <br />ROOFING MANUFACTURER'S RECOMMENDATIONS WHERE INDICATED AND AROUND <br />ENTIRE PERIMETER OF ROOFTOP EQUIPMENT. <br />ARCHITECTURE <br />�+ <br />INTERIORS <br />O <br />PROJECT <br />MANAGEMENT <br />J <br />PLANNING <br />U25 <br />N. Pine Street <br />Indianapolis, IN 46202 <br />www.meticulousda.com <br />W <br />info@meticulousda.com <br />v. 317.926.1820 <br />2 <br />f. 317.926.1815 <br />CIVIL ENGINEER: <br />,V()VS0 <br />ENGINEERING <br />STRUCTURAL ENGINEER, MEP & <br />LANDSCAPE ARCHITECT <br />7474 Noel Road <br />Indianapolis, IN 46278 <br />v. (317) 251-1738 <br />f. (317) 251-1923 <br />Blvd.mqimr 2211 E. Jefferson WDLZ South Bend, IN 46615 <br />ARCHITECTURE -ENGINEERING -PLANNING p• 574.236.4400 <br />EURVPYINC . CONSTRUCTION SPRVICPE <br />Z <br />w <br />U <br />O <br />0 <br />REVISIONS <br />re <br />1`E__ <br />w <br />U <br />J <br />G <br />00 <br />Q � <br />z <br />N m <br />N <br />Ln 4-J <br />r-I � <br />O <br />V) <br />No. Description Date <br />CERTIFIED BY: <br />rNOTFOR <br />CONSTRUCTION <br />ISSUE DATE: <br />08.04.2023 <br />DRAWN: CHECKED: <br />LH/VD/AR VD/JM <br />PROJECT NO.: P22-0125 <br />REVISION NO.: <br />ROOF PLAN - <br />a <br />l.ROOF PLAN -ALTERNATE. ©\ <br />A-160A 1/8" = 1'-0" IF <br />ALTERNATE NO. 7 <br />0 <br />m <br />lV <br />O <br />lV <br />