Laserfiche WebLink
f Annual Production <br />Description <br />Output <br />%Delta <br />Annual Global Horizontal Irradiance <br />1,400.6 <br />POA Irradiance <br />1,552.5 <br />10.8% <br />Irradiance <br />Shaded Irradiance <br />1,490.4 <br />-4.0%I <br />(kWh/mz) <br />f #¢dunce after Re <br />1,448.5 <br />-2.8% <br />Irradiance after Soiling <br />1,372.4 <br />-5.3% <br />Total Collector Irradiance <br />1,372.5 <br />0.0% <br />Nameplate <br />708,036.4 <br />Output at Irradiance Levels <br />702,929.0 <br />-0.7% <br />Output at Cell Temperature Derate <br />688,507.7 <br />-2.1 % <br />Energy <br />Output After Mismatch <br />644,112.1 <br />-6.4% <br />(kWh) <br />Optimal DC Output <br />642,122.0 <br />-0.3% <br />Constrained DC Output <br />639,632.9 <br />-0.4% <br />Inverter Output <br />630,002.2 <br />-1.5% <br />Energy to Grid <br />626,852.2 <br />-0.5% <br />Temperature Metrics <br />Avg. Operating Ambient Temp <br />13.5 °C <br />Avg. Operating Cell Temp <br />20.2 °C <br />Simulation Metrics <br />Operating Hours <br />4620 <br />Solved Hours <br />46201 <br />e Components <br />Component Name <br />Count <br />Inverters XGI 1500 200/200-480 <br />X00.0 kW) <br />(Solectria Solar) <br />Strings 10 AWG (Copper) <br />(0,147.4 <br />ft) <br />Module Crossroads Solar, CRS 144- <br />944 (514.5 <br />545 (545W) <br />kW) <br />• Condition Set <br />Description <br />Condition Set 1 <br />Weather Dataset <br />TMY, SOUTH BEND <br />MICHIANA RGNL AP, NSRDB (tmy3, 1) <br />Solar Angle Location <br />Meteo Lat/Lng <br />Transposition Model <br />Perez Model <br />Temperature Model <br />Sandia Model <br />Rack Type <br />a <br />b <br />Temperature Delta <br />Fixed Tilt <br />-3.56 <br />-0.075 <br />3°C <br />Temperature Model <br />Parameters <br />Flush Mount <br />-2.81 <br />-0.0455 <br />0°C <br />East-West <br />-3.56 <br />-0.075 <br />3°C <br />Carport <br />-3.56 <br />-0.075 <br />3°C <br />J F M <br />A M <br />J J <br />A S O N D <br />Soiling (%) <br />19 15 9 <br />3 3 <br />3 3 <br />3 3 3 3 15 <br />Irradiation Variance <br />5% <br />Cell Temperature <br />Spread <br />4° C <br />Module Binning Range <br />-2.5%to 2.5% <br />AC System Derate <br />0.50% <br />Maximum Angle <br />Trackers <br />60' <br />Module <br />Module <br />Characterizations <br />CRS 144-545 <br />(Crossroads Solar) <br />Device <br />Component <br />Characterizations <br />XGI 1500 200/200-480 <br />(Solectria Solar) <br />jL Wiring Zones <br />Description Combiner Poles String Size <br />Wiring Zone 18-25 <br />I.H. Field Segments <br />Intrarow <br />Description <br />Racking Orientation Tilt Azimuth <br />Spacing <br />Field <br />Fixed Portrait Module: Module: <br />16.5 ft <br />Segment 1 <br />Tilt (Vertical) 20° 180° <br />Backtracking <br />Enabled <br />Uploaded <br />By Characterization <br />Spec Sheet <br />HelioScope Characterization, PAN <br />Uploaded Characterization <br />By <br />i <br />HelioScope Spec Sheet <br />Stringing Strategy <br />Along Racking <br />Frame <br />Frames Modules Power <br />Size <br />514.5 <br />2x1 472 944 kW <br />