WDi Project Number 240318 26-Nov-24 Public Works Service Center Re -roofing <br />C. Store liquid materials in their original undamaged containers in a clean, dry, protected location; away from direct <br />sunlight; within the temperature range noted on the product data sheet. <br />D. Handle and store roofing materials and equipment in a manner to avoid permanent deflection of deck. <br />1.7 PROJECT CONDITIONS <br />A. Weather Limitations: Proceed with installation only when existing and forecasted weather conditions permit roofing <br />system to be installed according to manufacturer's written instructions and warranty requirements. <br />B. Daily Protection: Coordinate installation of roofing so insulation and other components of roofing system not <br />permanently exposed are not subjected to precipitation or left uncovered at the end of the workday or when rain is <br />forecast. <br />1. Provide tie -offs at and of each days work to cover exposed roofing and insulation with a course of roofing <br />sheet securely in place with joints and edges sealed. <br />2. Complete terminations and base flashings and provide temporary seals to prevent water from entering <br />completed sections of roofing. <br />3. Remove temporary plugs from roof drains at end of each day. <br />4. Remove and discard temporary seals before beginning work on adjoining roofing. <br />1.8 WARRANTY <br />A. Provide Manufacturer's 20 year warranty covering membrane, roof insulation, and system accessories. Comply <br />with all warranty procedures required by Manufacturer, including notifications, scheduling, and inspections. <br />1. Limit ofLiability: No dollar limitation(NDL) <br />B. Scope of Coverage: Repair leaks in the roofing system caused by <br />1. Ordinary wear and tear <br />2. Normal exposure to the elements <br />3. Manufacturing defects in materials <br />4. Defective workmanship used to install these materials <br />5. Damage due to winds up to 55 mph <br />PART 2 • GENERAL <br />2.1 MANUFACTURERS <br />A. Acceptable Manufacturers: Membrane <br />1. Elevate Building Products, Nashville, TN www.holcimelevate.com <br />2. GAF Materials Corp.Parsippany-Tray Hills, NJ www.gaf.cem <br />3. Johns Manville Corporation, Denver CO www.jm.com <br />4. Sika Roofing, Canton, MA www.usa.sika.com <br />5. Other approved by Architect prior to Bidding. See Section 016200. <br />B. Acceptable Manufacturers: Cover Board: <br />1. GP Gypsum Corporation. www.ao.cem <br />C. Source Limitations: Obtain components for roofing system from same manufacturer as membrane roofing or <br />manufacturer approved by membrane roofing manufacturer. <br />2.2 MATERIALS <br />A. Rigid Insulation <br />1. Type: ASTM C1289, Type II, rigid polyisocyanurate faced both sides with glass fiber mat facings <br />2. Thermal Resistance: As indicated by Drawings <br />3. Provide board tapered to 114 inch per foot <br />4. Maximum board size: 4 x 4 feet <br />B. Cover Board: <br />1. Type: ASTM C1177V177M or ASTM C1278IC1278M; 48 inches wide x thickness indicated, maximum <br />practical length, square cut ends and edges <br />2. Mold resistance: 10, tested to ASTM D3273. <br />C. Roof Membrane: <br />1. Type: ASTM D4434, reinforced plasticized polyvinyl chloride (PVC), ultraviolet resistant. <br />Polyvinyl Chloride Roofing 5 of 7 Section 07 5419 <br />