Laserfiche WebLink
STEVENSON MILL January 13, 2019 Revised January30, 2019 Page 2 of 9 Residents have complained about vibrations occurring in the building as a result of construction activity next-door. This vibration was most noticeable on the upper floors but the majority of the damage was found on the lower floors. This is where the stresses would have been the greatest. Keller Engineering performed an inspection of the interior of the hallways, a sampling of the apartments and an exterior inspection. Photographs were taken of areas of concern throughout the building. The most obvious damage was found in the drywall on the hallways on the lower levels. Multiple cracks were found in the drywall between the upper corners of doorways and the overhead beams. The cracks tended to follow the seams between drywall panels and typically followed a stair step pattern. It was difficult to focus a camera on the cracks, but here is a sampling. Keller Engineering, Inc. @UOD@OtiiUID 54365 30t11 Street• South Bend, Indiana 46635 • P: (574) 272-3525 • F: (574) 247-6006 www.KellerEngineeringinc.com