My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1316 East Wayne Street_AA 2024-0903
sbend
>
Public
>
Historic Preservation
>
2024
>
September
>
Administrative Approvals
>
1316 East Wayne Street_AA 2024-0903
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/4/2024 1:15:46 PM
Creation date
9/4/2024 1:17:12 PM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
1316 East Wayne Street South
HPC Document Type
Certification
HPC Local Historic District
viii. East Wayne Street
Text box
ID:
1
Creator:
Created:
9/4/2024 1:17 PM
Modified:
9/4/2024 1:15 PM
Text:
https://knowledge-center.solaredge.com/sites/kc/files/application_note_power_control_configuration.pdf
ID:
2
Creator:
Created:
9/4/2024 1:17 PM
Modified:
9/4/2024 1:15 PM
Text:
https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-inverter-lra-application-note-nam.pdf
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />© SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. <br />All other trademarks mentioned herein are trademarks of their respective owners. Date: February 19, 2024 DS-000229-NAM. Subject to change without notice. <br />SolarEdge Home Hub Inverter <br />Single Phase, for North America <br />SE3800H-US / SE5700H-US / SE7600H-US / SE10000H-US / SE11400H-US <br />Model Number(1)(2) SE3800H-US SE5700H-US SE7600H-US SE10000H-US SE11400H-US Units <br />OUTPUT – AC ON GRID <br />Rated AC Power 3800 @ 240V <br />3300 @ 208V <br />5760 @ 240V <br />5000 @ 208V 7600 10000 11,400 @ 240V <br />10,000 @ 208V W <br />Maximum AC Power Output 3800 @ 240V <br />3300 @ 208V <br />5760 @ 240V <br />5000 @ 208V 7600 10000 11,400 @ 240V <br />10,000 @ 208V W <br />AC Output Voltage (Nominal) 208 / 240 Vac <br />AC Output Voltage (Range) 183 – 264 Vac <br />AC Frequency Range (min - nom - max) 59.3 – 60 – 60.5(3) Hz <br />Maximum Continuous Output Current 16 24 32 42 48 A <br />GFDI Threshold 1 A <br />Total Harmonic Distortion (THD) < 3 % <br />Power Factor 1, adjustable -0.85 to 0.85 <br />Utility Monitoring, Islanding Protection, Country Configurable <br />Thresholds Yes <br />Charge Battery from AC (if allowed) Yes <br />Typical Nighttime Power Consumption < 2.5 W <br />OUTPUT – AC STAND-ALONE (BACKUP)(4)(5) <br />Rated AC Power in Stand-alone Operation 11,400(6) W <br />Maximum Stand-alone Capacity 11,400 W <br />AC L-L Output Voltage Range in Stand-alone Operation 211 – 264 Vac <br />AC L-N Output Voltage Range in Stand-alone Operation 105 – 132 Vac <br />AC Frequency Range in Stand-alone (min - nom - max) 55 – 60 – 65 Hz <br />Maximum Continuous Output Current in Stand-alone Operation 48 A <br />GFDI 1 A <br />THD < 5 % <br />OUTPUT – SOLAREDGE HOME EV CHARGER AC <br />Rated AC Power 9600 W <br />AC Output Voltage Range 211 – 264 Vac <br />On-Grid AC Frequency Range (min - nom - max) 59.3 – 60 – 60.5 Hz <br />Maximum Continuous Output Current @240V <br />(grid, PV and battery) 40 Aac <br />INPUT – DC (PV AND BATTERY) <br />Transformer-less, Ungrounded Yes <br />Max Input Voltage 480 Vdc <br />Nom DC Input Voltage 380 Vdc <br />Reverse-Polarity Protection Yes <br />Ground-Fault Isolation Detection 600kΩ Sensitivity <br />INPUT – DC (PV) <br />Maximum DC Power @ 240V 11,400 11,520 15,200 20,000 22,800 W <br />Maximum DC Power @ 208V 6600 10,000 - - 20,000 W <br />Maximum Input Current(7) @ 240V 20 30.5 40 53 60 Adc <br />Maximum Input Current(7) @ 208V 17.5 27 - - 53 Adc <br />Maximum Input Short Circuit Current 45 Adc <br />Maximum Inverter Efficiency 99.2 % <br />CEC Weighted Efficiency 98.5 99 99 @ 240V <br />98.5 @ 208V % <br />2-pole Disconnection Yes <br />(1) These specifications apply to inverters with part numbers SExxxxH-USMNUxxx5 and SExxxxH-USMNFxxx5 and connection unit model number DCD-1PH-US-PxH-F-x. <br />(2) Inverters with part number SExxxxH-USMNFxxx5 are intended for upgrade installations only, as part of the “Re-Energize” program. Use on non-upgrade installations will revoke the product warranty. <br />(3) For other regional settings please refer to the SolarEdge Inverters, Power Control Options Application Note. <br />(4) Not designed for non-grid connected applications and requires AC for commissioning. Stand-alone (backup) functionality is only supported for the 240V grid. <br />(5) For LRA (Locked Rotor Amperage) values please refer to the LRA for NAM Application Note. <br />(6) For models SE7600H-US and below, the rated AC stand-alone power is configurable between 7600W or 11,400W from CPU version 4.20.xx. <br />(7) A higher current source may be used. The inverter will limit its input current to the values stated.
The URL can be used to link to this page
Your browser does not support the video tag.