Laserfiche WebLink
Path \ File Name: C:\Users\jcbals\OneDrive\Z_PROJECTS\Catalyst-Two_Documentation-2024\- JADz_Drawings_Working\CatalystII-Documentation2024_X101Plot Date: July 15, 2024ABCDEFGHH.2JK <br />9 <br />8 <br />7 <br />6 <br />5 <br />4 <br />3 <br />2 <br />1 <br />LMNPQR <br />ABCDEFGHH.2JKLMNPQR <br />9 <br />8 <br />7 <br />6 <br />5 <br />4 <br />3 <br />2 <br />1 THESE DRAWINGS AND THE INFORMATION THEY CONTAIN ARE THE SOLEPROPERTY OF JOSEPH A. DZIERLA & ASSOCIATES, INC. AND MAY NOT BEREVISED, REPRODUCED, OR DISTRIBUTED IN ANY MANNER WITHOUT THEEXPRESS CONSENT OF JOSEPH A. DZIERLA & ASSOCIATES, INC.© COPYRIGHT 2024 | ALL RIGHTS RESERVEDProject Number:319 SOUTH MAIN STREET, SUITE 300SOUTH BEND, INDIANA 46601PHONE: 574-234-8619FAX: 844-272-0063EMAIL: dzierla@outlook.comISSUE DATE <br />REVISIONSCATALYST TWO:EXISTING DOCUMENTATION1165 FRANKLIN STREETSOUTH BEND, INDIANA 46601EXISTING DOCUMENTATION <br />15 JULY 2024 <br />XX-XXX-X <br />CATALYST TWO: EXISTING DOCUMENTATION 2024BUILDING EXISTING PLANx1.1 <br />1. THESE EXISTING BUILDING DOCUMENTS ARE CREATED BASED UPON <br />INFORMATION OBTAINED THROUGH SITE OBSERVATIONS, FIELD MEASUREMENTS, <br />AND AVAILABLE GIS DATA. <br />2. THE ARCHITECT HAS MADE A REASONABLE EFFORT TO ENSURE THE ACCURACY <br />OF THESE EXISTING BUILDING DOCUMENTS, BUT MINOR INACCURACIES MAY <br />EXIST DUE TO THE NATURE OF DOCUMENTING EXISTING CONSTRUCTED <br />BUILDINGS. <br />3. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR(S) TO FIELD VERIFY ANY <br />AND ALL CRITICAL DIMENSIONS REQUIRED FOR PERFORMING NEW WORK. <br />4. CONTRACTOR(S) SHALL NOTIFY THE ARCHITECT OF ANY MAJOR DISCREPANCIES <br />THAT MAY PROHIBIT OR ALTER THE IMPLEMENTATION OF THE DESIGN FOUND IN <br />THESE CONSTRUCTION DOCUMENTS. <br />EXISTING PLAN NOTES <br />0 <br />1 <br />X1.1 <br />BUILDING EXISTING PLAN <br />SCALE: 1/16" = 1'-0" <br />PLAN <br />NORTH <br />4' 8' 16'32' <br />0 <br />2 <br />X1.1 <br />TENANT SECOND FLOOR EXISTING PLAN <br />SCALE: 1/16" = 1'-0" <br />PLAN <br />NORTH <br />4' 8' 16'32' <br />CONSTRUCTION GROSS AREA <br />49,869 SQ. FT. (1st FLOOR) <br />EXTERIOR GROSS AREA <br />47,697 SQ. FT. (1st FLOOR) <br />INTERIOR GROSS AREA <br />46,938 SQ. FT. (1st FLOOR) <br />SUITE 220 <br />2,760 SQ. FT. <br />SUITE 240 <br />3,564 SQ. FT. <br />SUITE 100 <br />5,093 SQ. FT. <br />SUITE 120 <br />1,356 SQ. FT. <br />SUITE 140 <br />1,139 SQ. FT. <br />SUITE 160 <br />2,227 SQ. FT. <br />SUITE 180 <br />6,075 SQ. FT. <br />BUILDING UTILITY <br />422 SQ. FT. <br />SERVICE AREAS <br />899 SQ. FT. <br />CIRCULATION AREAS <br />792 SQ. FT. <br />SUITE 200 (FIRST) <br />22,609 SQ. FT. <br />SUITE 200 (SECOND) <br />7,596.43 SQ. FT. <br />OPEN T <br />O <br /> <br />B <br />E <br />L <br />O <br />W <br />OPEN T <br />O <br /> <br />B <br />E <br />L <br />O <br />W <br />OPEN T <br />O <br />BELOW <br />OPEN TOBELOW