Laserfiche WebLink
5'-0"Min.10'-0"Min.Side Sewer <br />Lot Line <br />Tree <br />10'Std.Approx. R/W <br />Approx. R/W Approx. R/W5'-0"Min.5'-0"Std.Curb or Edge of <br />Traveled Portion <br />of Roadway <br />3'-0" Min. <br />15'-0" Max. on Corners <br />7'-0" Max. Midblock <br />10'-0" <br />Std. <br />N or E <br />3'-0" Min. (Typ.) <br />Otherwise Easement <br />is Req'd. <br />Minimum of 4'-0" Clearance Between <br />Fire Hydrant and Utility Pole, <br />Guard Post, Building Wall or any <br />Fixed Str.C StreetL2'-0" Min. <br />1'-6"2'-0"5'-6"Expansion <br />Joint <br />Face of CurbSee Detail A <br />Corner <br />Corner <br />Mid-Block <br />DETAIL A <br />Hydrant Near Curb Ramp <br />NOTES: <br />1.No parking zone within 15'-0" radius of fire hydrant. <br />2.Min. distance from back face of hydrant to front edge of concrete <br />walk shall be 2'-0". <br />3.Fire hydrant spacing shall be no greater than 500 ft. <br />4.Fire hydrant shall not be placed within pedestrian access.6'8' <br />LEGEND: <br />Fire hydrant <br />6/26/18 <br />CITY OF SOUTH BENDItemRevision <br />STANDARD <br />EFFECTIVE DATE: <br />REF STD SPEC SEC <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />Kara M. Boyles, Ph.D., P.E. Date <br />FIRE HYDRANT LOCATION AND CLEARANCES 5-10 <br />5-2.6 and 5-3.10 <br />June 26, 2018 <br />SECTION 5 - WATER WORKS