Laserfiche WebLink
Fill Void w/ Flowable Fill (Removable) <br />as Directed by Engineer <br />Cement Mortar <br />Under Pipe <br />Water Pipe <br />(Size per Plan <br />and Specs.) <br />Seal Ends w/ <br />Concrete <br />Steel Pipe Casing <br />(Size per Plan and Specs.) <br />Steel Pipe Casing <br />(Size per Plan and Specs.) <br />Carrier Pipe <br />Stainless Steel Casing Spacers <br />or Non-Corrodible Rail/Skid Castings <br />Stainless Steel Casing Spacers <br />or Non-Corrodible Rail/Skid Castings <br />SECTION <br />NOTES: <br />1.All steel casing pipe sizing shall be designed by the Project Engineer. Steel <br />casing pipe, including wall thickness shall conform to INDOT Standard <br />Specification Section 716. Design approval of steel casing pipe shall be granted <br />by the City Engineer. <br />2.For railroad crossings, steel casing pipe shall conform to the regulating railroad <br />authority's design and permitting requirements. <br />6/26/18 <br />CITY OF SOUTH BENDItemRevision <br />STANDARD <br />EFFECTIVE DATE: <br />REF STD SPEC SEC <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />Kara M. Boyles, Ph.D., P.E. Date <br />TYPICAL WATER CASING DETAIL 5-5 <br />5-2.9 <br />June 26, 2018 <br />SECTION 5 - WATER WORKS