My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10.26.2021-SBN-Standards-Manufacturer-Additions-Minor-Revisions-final
sbend
>
Public
>
Public Works
>
City of South Bend Construction Standards & Specifications
>
10.26.2021-SBN-Standards-Manufacturer-Additions-Minor-Revisions-final
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2024 3:44:43 PM
Creation date
5/6/2024 3:43:30 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
City Property
Document Date
5/6/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PLAN VIEW <br />9'-9 1/2"**4'-0"**2'-6"*1'-6"* <br />Flow <br />12'**8'**1" Conduit for <br />Flow Meter Cable <br />__" D.I. Plug Valve (Typ.) <br />__" D.I. Pipe <br />(Typ.) <br />3" Drain Line <br />to Wetwell <br />Below __" <br />Forcemain <br />__" D.I. Pipe <br />45° Wye (Typ.) <br />Pre-Cast Concrete Vault Designed for <br />H-20 Loading and ASTM C857 and C858 <br />__"x__" D.I. Pipe Reducer <br />Restrained Transition Coupling <br />Flow <br />__" Flow Meter <br />Access Cover <br />SECTION A-A VIEW <br />FITTING CONFIGURATION <br />* Length Per Meter Manufacturer Recommendations <br />** Varies Per Pipe Size and Meter Size <br />Pre-Cast Extension With <br />3'x3' Inside Dimensions <br />__" Core Drill w/Link Seal (Typ.) <br />__"x__" D.I. Pipe Reducer <br />Restrained Transition Coupling <br />Forcemain Pipe With <br />Transition Pipe Adapter <br />Flow <br />__" Flow Meter <br />Flow <br />See Access Cover Detail <br />PCCP on Compacted Aggregate <br />Pre-Cast Concrete Vault Designed for <br />H-20 Loading and ASTM C857 and C858 <br />1" Conduit for <br />Flow Meter Cable <br />3" PVC SCH 80 Drain <br />Line to Wetwell <br />Core Drill w/Link Seal <br />5% Slope <br />Grout Slope to Drain Line <br />12'**2"12"A A <br />6/26/18 <br />CITY OF SOUTH BENDItemRevision <br />STANDARD <br />EFFECTIVE DATE: <br />REF STD SPEC SEC <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />Kara M. Boyles, Ph.D., P.E. Date <br />FLOW METER VAULT 4-17 <br />4-2 and 4-3 <br />June 26, 2018 <br />SECTION 4 - SANITARY <br />NOTES: <br />1. For clarity pipe support/stands are not shown. Contractor shall furnish and install all <br />pipe supports per manufacturer's recommendations. Pipe supports shall be made of <br />stainless steel or concrete. <br />2. Provide stainless steel cable supports for the flow meter power/control cable. <br />3. All piping and valves in the lift station to the meter vault and inside the meter vault <br />shall be Ductile Iron pipe.
The URL can be used to link to this page
Your browser does not support the video tag.