Laserfiche WebLink
Road Way Snakepit Magnetized Tracer Box by <br />Copperhead Industries, or <br />Equal w/ "SEWER" on lid <br />PVC or H.D.P.E. Force Main <br />24" x 24" x 6" Class "A" Conc. Pad <br />Two (2) #8 Copper Wire <br />Continuous Insulated <br />18"3" Wide Magnetic or <br />Non-Magnetic Detection <br />Tape <br />6/26/18 <br />CITY OF SOUTH BENDItemRevision <br />STANDARD <br />EFFECTIVE DATE: <br />REF STD SPEC SEC <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />Kara M. Boyles, Ph.D., P.E. Date <br />FORCE MAIN TRACER WIRE RISER 4-13 <br />4-2 and 4-4 <br />June 26, 2018 <br />SECTION 4 - SANITARY <br />NOTES: <br />1.All force main pipe shall be installed with an electronically continuous type TW <br />insulated #8 tracing wire. <br />2.Markers shall be placed at 400' intervals minimum and all changes in direction. <br />The tracer wire shall be connected to the terminal in each marker. <br />3.Forcemain tracing wire shall maintain connectivity throughout the length of the <br />forcemain, including at any changes in direction, structures, air release valves, <br />manholes, pipe markers, etc. <br />4."SEWER" Cast-on lid. <br />5.Poured in place concrete pad, 24" x 24" x 6" with perimeter reinforcing. <br />6.Wire taped at each side of pipe joint and 6' O.C.