Laserfiche WebLink
NOTES: <br />1. Used to separate disparate longitudinal types of pavement only. <br />2. Concrete Header to be constructed of class "A" concrete. <br />3. Control joints to be placed every 10'. <br />4. Expansion joints to be placed every 80' or as specified on construction drawings. <br />6" <br />Min. <br />6" <br />Min.12"Min.1 4" R <br />HMA Pavement Concrete Pavement <br />6/26/18 <br />CITY OF SOUTH BENDItemRevision <br />STANDARD <br />EFFECTIVE DATE: <br />REF STD SPEC SEC <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />Kara M. Boyles, Ph.D., P.E. Date <br />DETAILS - STANDARD HEADER 2-36 <br />2-2 <br />June 26, 2018 <br />SECTION 2 - STREETS AND PATHS