My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotes- Century Center Water Softener System - DA Dodd
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2023
>
Opening of Quotations/Proposals
>
Opening of Quotes- Century Center Water Softener System - DA Dodd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2023 2:34:00 PM
Creation date
9/26/2023 2:33:40 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
9/26/2023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
B. Provide slide type supports where only lateral control is required. <br />PART 3: EXECUTION <br />3.1 SUPPORT <br />A. Provide supports for horizontal piping (copper or ferrous) at intervals as follows (but not <br />less than one per branch): <br />HANGER SPACING TABLE <br />Pipe (inches) Rod (inches) Steel Pipe <br />Spacing (feet) <br />Copper Pipe <br />Spacing (feet) <br />½ and 3/4 3/8 6 5 <br />1 and 1 1/4 3/8 8 6 <br />1 1/2 and 2 3/8 10 8 <br />2 ½½11 8 <br />3 ½12 10 <br />4 and 5 5/8 16 12 <br />6 3/4 16 12 <br />B. Spacing for hangers on plastic piping shall be in accordance with manufacturer's <br />recommendations based on maximum system temperature plus ten (10) degrees. <br />C. Where hangers or shields come in contact with non-ferrous metallic piping, provide <br />plastic or rubber pipe guides or plastic or copper coated pipe components for portion in <br />contact with piping. <br />D. Support vertical piping at every floor level or at least every twenty-five feet (25') by <br />heavy iron extension pipe clamps having bolts on each side and ends having equal <br />bearing on structure. Support base of vertical piping by hanger placed on horizontal <br />branch close to riser or base fitting set on foundation. Provide intermediate iron or <br />plastic supports as required for smaller piping and rough-ins to prevent sagging and <br />vibration. <br />E. Support piping independently at all pumps, tanks and all other equipment so that <br />equipment is not stressed by piping weight or expansion. <br />F. Supports of wire, rope, wood, chain, strap, perforated bar, or any other makeshift device <br />are not permitted. <br />G. Contractor shall be responsible for proper location of all concrete inserts and anchor <br />rods. <br />15140 - 2