3. 1205 East Wayne Street North_COA 2023-0803
sbend
>
Public
>
Historic Preservation
>
2023
>
August
>
3. 1205 East Wayne Street North_COA 2023-0803
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/14/2023 1:39:31 PM
Creation date
8/14/2023 11:55:37 AM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
1205 East Wayne Street North
HPC Document Type
Certification
HPC Local Historic District
viii. East Wayne Street
Text box
ID:
1
Creator:
Created:
8/14/2023 1:09 PM
Modified:
8/14/2023 1:09 PM
Text:
http://www.kilarchitecture.com/
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br />K I L <br />ARCHITECTURE <br />P L A N N I N G <br />www.kilarchitecture.com <br /> <br />1 1 2 6 L I N C O L N W A Y E A S T S O U T H B E N D I N 4 6 6 0 1 ( 5 7 4 ) 2 8 8 . 2 6 5 4 V O I C E 2 8 9 . 2 4 2 0 F A X <br />1.) Roof Replacement: Photos 1-7 <br /> The existing roof is covered with asphalt architectural shingles with metal flashing <br />and drip edges. This roof is compromised and is otherwise at the end of its useful life. This <br />project proposes removal of the existing roofing on both the house and garage to be replaced <br />and upgraded with new EcoStar synthetic slate with a random width blend (6”,9”,12”) and <br />color blend TBD (first choice) with copper flashings and drip edges. This roofing upgrade <br />will include a copper metal pan (flat seam) roofing system at the valley between porch turret <br />and main house where roof extends behind the chimney, this is to ensure a better system to <br />carry water away from main roof and direct it around the chimney. This will be mostly <br />blocked by the chimney from view and is necessary to provide a more resilient roofing <br />system to avoid future issues at the chimney. This new roofing will include new ice and <br />water shield underlayment’s over the entire roof. <br /> <br />2.) New Gutters & Downspouts: Photos 1-7 <br /> The existing gutters are painted 4” half round, with round downspouts. The existing <br />fixtures are damaged and missing in many locations. This project proposes replacement and <br />upgrading of the gutter system with new 5” half round gutters and round downspouts in <br />copper. New concrete splash blocks will be installed at grade for all downspouts. <br /> <br />3.) Chimney Reconstruction: Photos 8-9 <br /> The existing chimney has begun to list away from the main structure and is <br />approximately 6” out of plumb due to inappropriate flashing between the roof and chimney <br />which has allowed moisture to infiltrate the chimney stack. This project proposes taking the <br />masonry chimney down to the foundation and reconstruct using the original masonry units as <br />much as possible with replacements sourced to match original materials and will use a lime- <br />based mortar of a mix to match the existing composition and strength. The reconstructed <br />chimney will replicate the existing in material, dimension, tooling, design, detailing, etc. If <br />the fireplace lining is found to be in good condition, the chimney may only be brought down <br />to the limestone level. A new stone cap is proposed to replace the existing stone piece at the <br />top of the chimney and at the buttress at the lower mass. Additionally, where the masonry <br />transitions between limestone and brick, the profile steps back with a sloped brick transition <br />with limestone corners. This project would like to request use of limestone for these sloped <br />brick panels in order to reduce the number of horizontally exposed head joints. <br /> <br />4.) Masonry Re-Pointing & Lintel Replacement: Photos 10-11 <br /> This portion is focused on masonry maintenance around the entire home, with <br />additional focus given to two specific lintels and window surrounds. Existing are two cast <br />concrete lintels with steel reinforcement – one each located on the south and west elevations <br />at the ground floor level. Due to rust expansion of the steel reinforcement blowing out the <br />face of the concrete lintels, this project proposes replacement of each of these lintels and <br />associated surrounds and sills with new limestone components carved to match the existing
The URL can be used to link to this page
Your browser does not support the video tag.