My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Angela Street Bridge_AA 2023-0515
sbend
>
Public
>
Historic Preservation
>
2023
>
June
>
Administrative Approvals
>
Angela Street Bridge_AA 2023-0515
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2023 2:05:07 PM
Creation date
5/15/2023 2:05:40 PM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
Angela Street Bridge
HPC Document Type
Certification
HPC Local Landmark
i. South Bend
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
February 26, 2018 Page 2 of 7 <br />The HMA coarse aggregate materials shall meet the requirements of 904.03(b), except the coarse <br />aggregate angularity table shall be modified as follows: <br /> <br />COARSE AGGREGATE ANGULARITY <br />Type Depth from Surface <br />≤ 4 inches > 4 inches <br />A 55 <br />B 75 50 <br />C 85/80* 60 <br />*Note: Denotes two faced crushed requirements. <br /> <br />HMA coarse aggregates for surface mixtures shall meet the requirements of Section 904.03(d), except <br />they may be modified as follows when the design speed or posted speed limit is equal to or less than 45 <br />mph. <br /> <br />Coarse Aggregate Type Traffic ESALs <br />< 3,000,000 < 10,000,000 ≥ 10,000,000 <br />Air-Cooled Blast Furnace Slag Yes Yes Yes <br />Steel Furnace Slag Yes Yes Yes <br />Sandstone Yes Yes Yes <br />Crushed Dolomite Yes Yes Yes <br />Polish Resistant Aggregates Yes Yes Yes <br />Crushed Stone Yes Yes * <br />Gravel Yes Yes * <br />*Note: Crushed Stone or gravel may be used in accordance with ITM 221. <br /> <br />HMA.04 Design Mix Formula and Mixture Type <br />The design mix formula (DMF) shall be prepared by an INDOT approved Mix Design Laboratory in <br />accordance with Section 401.05 and submitted to the Contracting Agency in an acceptable format one <br />week prior to use. The DMF shall be based on the mixture type (design ESAL) and mixture designation of <br />the following tables. <br /> <br />Mixture Type Type A* Type B* Type C* <br />Design ESAL <300,000 300,000 to <3,000,000 ≥3,000,000 <br />AADT (Average Annual <br />Daily Traffic)*** <4,000 4,000 - 15,000 15,000 - 30,000 <br />AADTT (Average Annual <br />Daily Truck Traffic)*** <50 50 - 1700 >1700 <br />Commercial & Residential <br />Application*** <br />Passenger car parking <br />with <500 stalls and <br /><20 heavy trucks** <br />per day, residential <br />driveways <br />Parking Lots with <br />20-300 heavy trucks** <br />per day <br />Heavy commercial <br />parking lots with <br />150-300 heavy <br />trucks** per day <br />
The URL can be used to link to this page
Your browser does not support the video tag.