Laserfiche WebLink
ELEVATION <br />30’-0" max.30’-0" max. <br />A <br /> of Railing, TX3’-8" - Pay LimitsELEVATION SHOWING REINFORCING STEEL <br />2 3/4" (5702E spacing)2 3/4"6" max. spacing <br />Dimension depends on the number of windows and the dimension "X" <br />A <br />SECTION A-A <br />PILASTER (typ.) <br />END BENT <br />PILASTER (typ.) <br />PIER <br />PILASTER <br />SPAN <br />PILASTER <br />SPAN <br />Concrete bridge deck slab <br />(2 each face) <br />#5E x (length varies) <br />PILASTER (typ.) <br />END BENT <br />PILASTER <br />SPAN <br />PILASTER <br />SPAN <br />PILASTER (typ.) <br />PIER <br />30’-0" max. <br />Dimension depends on the number of windows and dimension X <br />1 1/2" width <br />Notches <br />1 1/2" width <br />Notches <br /> 1’-0"2 3/4" (5700E spacing)2 3/4" <br /> to joint - Pay limits of concrete railing, TX <br /> pierEnd of bridge slab <br />6"6"X X XX1’-4 1/2"1’-0"1’-0"1’-0"1’-0"1’-4 1/2" <br />6"6"6"6"6"1’-0"1’-0"1’-0"a6"6"6"6"1’-0"1’-0"6"6"6"6"6"6"6"6"1’-0"1’-0"1’-0"1’-0"a <br />4"4"4"4"4"4" <br />5700E <br />#7E Bent Bar (2 each face) <br />5702E <br />x 1’-6" <br />No. of Windows <br />x 1’-6" <br />No. of Windows <br />x 1’-6" <br />No. of Windows <br />STANDARD DRAWING NO. <br />INDIANA DEPARTMENT OF TRANSPORTATION <br />E 706-BRTX-01 <br />(typ.) <br />(typ.) <br />(typ.) <br />TYPICAL PANEL <br />RAILING, TX <br />pilaster details. <br />See Standard Drawing E 706-BRTX-04 for pier and end bent 10 <br />See Standard Drawing E 706-BRTX-03 for span pilaster details.9 <br />details. <br />Window opening. See Standard Drawing E 706-BRTX-02 for 8 <br />All reinforcing bars designated E shall be epoxy coated.7. <br />Transition, TTTX. <br />See Standard Drawing E 706-TTTX-01 for Concrete Bridge Railing 6. <br />= 6". <br />Dimension a = 2X + 3 1/2". Space bars within dimension a equally 5 <br />pilasters does not decrease the integrity of the railing. <br />Span pilasters are for aesthetic purposes only. Omitting span 4. <br />Span pilasters may be omitted for a short span with X = 2’-0".3. <br />span length. <br />Select the number of windows and adjust dimension X to fit the 2 <br />See Standard Drawing E 706-BRTX-02, -03, and -04 for sections.1. <br />NOTES <br />SEPTEMBER 2012 <br />8 <br />8 <br />8 <br />10 9 9 10 <br />5 5 <br />2 2 2 2 <br /> <br />/s/ Richard L. VanCleave 09/04/12 <br />DATESUPERVISOR, ROADWAY STANDARDS <br />/s/ Mark A. Miller 09/04/12 <br />DATECHIEF ENGINEER <br />STATE OF <br />No. <br />AAD <br />I <br />N I NPROFES <br />O <br />I <br />S <br />N LA <br />NE <br />IGENRERGEISTERDE RICHARD L. V <br />anCLE <br />A <br />VE <br />9750