Laserfiche WebLink
CASCADE ENGINEERING Report No.:3182829GRR-001C <br />Date: July 17, 2009 Reference No.: 09-0603-202466 <br />P.O. No.: ISE15448 Page 3 of 11 <br /> <br />VOLUMETRIC LOADING CAPACITY TEST A: <br />Date Tested: 06/22/09 <br /> <br />Description of Samples: <br />Part Description: 96 Cart <br />Sample Condition: Production <br /> <br />Test Procedure: <br />Test Method: Place the empty container on a scale and record the <br />weight. Place the empty container in a tank full of <br />water with a temperature of 59 °F ± 9 °F. Fill the <br />container up to the rim and then place the container <br />on a scale. Record the difference from the full <br />container and the empty container. <br />Water Temp: 62 ° <br />Number of Specimens Tested: Two (2) Carts <br /> <br />Acceptance Criteria: <br />Accuracy of measurement must be ± 2 % of the measured capacity of the container. <br /> <br />Results: <br /> <br />Sample Description Actual Capacity % Difference <br />96 Universal 95.76 -.25 <br />96 Automatic 95.75 -.26 <br /> <br />The submitted samples meet the acceptance level criteria. <br /> <br />