Laserfiche WebLink
CASCADE ENGINEERING Report No.:3182829GRR-001B <br />Date: July 17, 2009 Reference No.: 09-0603-202466 <br />P.O. No.: ISE15448 Page 6 of 11 <br /> <br /> <br />LOADING AND UNLOADING TEST D: <br />Dates Tested: 06/24/09 - 06/25/09 <br /> <br />Description of Samples: <br />Part Description: 64 Gallon Cart <br />Sample Condition: Production <br /> <br />Test Procedure: <br />Test Method: The test was performed at room temperature with a <br />cycle time that simulates lift, dump and return in not <br />less than 8 seconds. The cart was loaded to 226 lbs. <br />(+15-0 lbs.) Note: ANSI standards require a load <br />specified on cart that is 224 lbs. <br />Number of Cycles: 520 Cycles <br />Number of Specimens Tested: One (1) 64 Gallon Cart <br /> <br />Acceptance Criteria: <br />Carts shall remain water tight and functional through 520 cycles. <br /> <br />Results: <br /> <br />Number of Cycles Description <br />0 Start of Test <br />520 Test Completed - Pass <br /> <br />The submitted sample meets the acceptance level criteria. <br /> <br />