Laserfiche WebLink
<br />Suzuki Garphyttan CorporationIndustrial Wastewater Discharge Permitpage 9 of 47 <br />Facility Description <br /> <br />Suzuki Garphyttan Wire engages in the manufacture of steel wire automotive springs. The spring wire <br />manufacturing consists of acid cleaning, drawing and zinc phosphate coating. Suzuki is Categorical Industrial <br />User (CIU) as defined in the South Bend Municipal Code. Specifically Suzuki is classified as a metal finisher <br />covered by 40 CFR 433.17 (PSNS) due to the zinc phosphate coating. <br /> <br />PART I – EFFLUENT LIMITATION <br /> <br />A. Sample Port and Collection Location <br />1. Sample Site Outfall #231 is located outside the main facility in a locked shed, which is attached to <br />the north wall of the building. The wastewater discharge flows through a weir box for flow <br />measurement in the shed prior to discharge. The composite sample is collected in the discharge pipe <br />after the final chamber of the weir box. Grab samples are collected after the final discharge tank in <br />the weir box. Samples are of process water only, sanitary is excluded. <br /> <br />2. Any discharge of water or waste having a pH lower than 6.0 S.U. or a pH higher than 11.0 S.U. <br />is prohibited. In addition, the permittee’s wastewater discharge shall not exceed the following <br />effluent limitations: <br /> <br /> Effluent limitations for Sample Site Outfall # 231: <br />Parameter Daily Maximum Limit (mg/L) Monthly Average Limit (mg/L) <br />Arsenic (mg/L) 1.0 0.3 <br />Cadmium (mg/L) Report* Report* <br />Chromium (mg/L) 2.77 1.71 <br />Copper (mg/L) 3.38 0.8 <br />Cyanide (mg/L) 1.20 0.65 <br />Lead (mg/L) 0.69 0.43 <br />Mercury (mg/L) 0.00019 --NA-- <br />Nickel (mg/L) 3.98 0.8 <br />Oil & Grease (mg/L) 300 --NA-- <br />Oil and Grease TPH (mg/L) 100 --NA-- <br />Silver (mg/L) 0.43 0.24 <br />TTO (mg/L) 2.13 --NA-- <br />Zinc (mg/L) 2.61 1.48 <br /> <br />*Note: In accordance with the City of South Bend’s “What You Need Is What You Get” allocation method, local Daily Maximum and Monthly <br />Average limits have only been developed for those pollutants that have been observed at or above certain concentrations in each Significant <br />Industrial User’s wastewater discharge. If “Report” appears on the table, it has been determined that an allocation of this pollutant is not <br />necessary. The permittee shall compare any monitoring data for these pollutants with the screening table in Part I (3) below. If pollutant <br />concentrations above the screening levels are observed, a local Daily Maximum and/or Monthly Average limit may be developed for that pollutant.