My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
211 North Michigan Street_AA 2022-0719
sbend
>
Public
>
Historic Preservation
>
2022
>
August
>
Administrative Approvals
>
211 North Michigan Street_AA 2022-0719
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2022 1:47:24 PM
Creation date
7/21/2022 1:47:19 PM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
211 North Michigan Street
HPC Document Type
Certification
HPC Local Landmark
i. South Bend
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Product Data <br />APPLICATION PHYSICAL PROPERTIES (cont.) <br />45 mil FiberTite-SM-FB Roofing Systems are installed by adhering <br />the “fleece back” membrane in FTR-290 low VOC solvent borne <br />adhesive, FTR-390 water borne asphalt emulsion, FTR-490 water <br />borne elastomeric adhesive, FTR CR-20, or hot asphalt to a variety <br />of pre-approved substrates. <br />For specific installation recommendations and requirements, <br />please consult the most current versions of Seaman <br />Corporation’s Guide Specifications for the Installation of FiberTite <br />Roofing Systems. <br />45 mil FiberTite-SM-FB <br />Accelerated Weathering <br />Practice G 155 / xenon <br />5000hr >10000hr <br />cracking (7x magnification)none none <br />crazing (7x magnification)none none <br />Accelerated Weathering <br />Practice G 154 / UVA <br />5000hr >10000hr <br />cracking (7x magnification)none none <br />crazing (7x magnification)none none <br />Fungi Resistance Sustained Growth <br />Practice G 21, 28 days Discoloration <br />no growth <br />none <br />no growth <br />none <br />Abrasion Test, cycles <br />D 3389 H-18 wheel / 1,000 g load <br />1,500 2,000+ <br />Additional Physical Properties <br />Tensile Strength (psi) <br />ASTM D882 <br />8500 <br />Breaking Strength (lbs) <br />ASTM D751, Grab Method <br />450 <br />Puncture Resistance (lbs) <br />ASTM D751, Bursting Strength <br />350 <br />Water Vapor Transmission <br />ASTM E96 proc. A (gm/m2/24hrs) <br />1.3 <br />Shore A Hardness <br />ASTM D2240 <br />87 <br />Flame Resistance <br />MIL-C-20696C / Type II Class 2 <br />pass <br />Oil Resistance, MIL-C 20696C <br />No swelling, cracking or leaking <br />none <br />Hydrocarbon Resistance, MIL-C-20696C <br />No swelling, cracking or leaking <br />none <br />High Temperature Dead Load <br />ASTM D751 (50 lbs, 160°F, 4 hrs) <br />pass <br />Energy Attributes DC196 Off White DC6 White DC691 CR Gray DC667 CR Tan <br />Initial Solar Reflectance <br />ASTM C1549 0.83 0.87 0.69 0.72 <br />Solar Reflectance (3 yr aged) <br />ASTM C1549 0.66 0.71 .61 .63 <br />Initial Thermal Emittance <br />ASTM C1371 0.85 0.85 0.89 0.88 <br />Thermal Emittance (3 yr aged) <br />ASTM C1371 0.74 0.84 .89 .89 <br />Solar Reflective Index (SRI) <br />ASTM E1980 104 110 84 88 <br />Solar Reflective Index (SRI) (3 yr aged) <br />ASTM E1980 76 86 73 76 <br />Energy Star YES YES YES YES <br />LEED v4 - Heat Island Reduction <br />SS Credit 1 Credit 1 Credit 1 Credit 1 Credit
The URL can be used to link to this page
Your browser does not support the video tag.