Interior Assessment of Paint Deterioration <br />Window Type None <br />Description Substrate -Wood; Side -C -Side; Deterioration -Chipped or Peeled <br />Hazard YES Result XRF Test: 27.2 mg/cm2 <br />Assessment Notes <br />Remediation Options INTERIM CONTROLS: <br />I .Stabilize deteriorated paint on door surface, panels(s), stiles and rails. <br />ABATEMENT: <br />].Enclose the door component with a barrier completely preventing access, as <br />noted, <br />2.Remove all of the paint or coating fi•om the door component using lead safe <br />work practices and resurface with lead free paint or other coating <br />3.Replace door or door parts with lead free components, completely or <br />partially, as noted in Specific Instructions, below. <br />Specific Instructions Wet scrape and repaint, cover with barrier such as <br />packing tape, or replace <br />Repair Substrate None <br />Component Location -Type Other -- Door Casing <br />Window Type None <br />Description Substrate -Wood; Side -C -Side; Deterioration -Chipped or Peeled <br />Hazard YES Result XRF Test: 3.3 mg/cm2 <br />Assessment Notes Component Location: Bedroom 5 <br />Remediation Options INTERIM CONTROLS: <br />].Stabilize deteriorated paint on window. <br />ABATEMENT: <br />l .Enclose the component with a barrier completely preventing access, as noted. <br />2,Remove all of the paint or coating from the window component using lead <br />safe work practices and resurface with lead free paint or other coating. <br />3.Replace window or window parts components with lead free components, <br />completely or partially, as noted in Specific Instructions, below. <br />Specific Instructions NONE <br />Repair Substrate NONE <br />Component Location -Type Other -- Window <br />Window Type Window Casing <br />Description Substrate -Wood, Side -A -Side; Deterioration -Chipped or Peeled <br />Hazard YES Result XRF Test: 11.5 mg/cm2 <br />Assessment Notes Component Location: Bedroom 5 <br />Remediation Options INTERIM CONTROLS: <br />LStabilize deteriorated paint on window. <br />RiskAssessmentft.: 84000015462 Address: 628PARKAVE Page 12 of 23 <br />