Laserfiche WebLink
Interior Assessment of Paint Deterioration <br />Component Location -Type Bathrooml -- Door Casing <br />Window Type None <br />Description Substrate -Wood; Side -B -Side; Deterioration -Chipped or Peeled <br />Hazard YES Result XRF Test: 2.2 mg/cm2 <br />Assessment Notes <br />Remediation Options INTERIM CONTROLS: <br />].Stabilize deteriorated paint on door casing and jamb. <br />ABATEMENT: <br />].Enclose the door component with a barrier completely preventing access, as <br />noted. <br />2.Remove all of the paint or coating from the door component using lead safe <br />work practices and resurface with lead free paint or other coating <br />3,Replace door or door parts with lead free components, completely or <br />partially, as noted in Specific Instructions, below. <br />Specific Instructions Wet scrape and repaint, cover with barrier such as <br />packing tape, or replace <br />Repair Substrate NONE <br />Component Location -Type Bathroom -- Other <br />Window Type None <br />Description Substrate -Metal; Side -D -Side; Deterioration -Chipped or Peeled <br />Hazard YES Result XRF Test: 7 mg/cm2 <br />Assessment Notes Component Type: Radiator <br />Remediation Options INTERIM CONTROLS: <br />I. Stabilize deteriorated paint and cover the current component with a lead-free <br />component <br />Specific Instructions <br />Repair Substrate <br />ABATEMENT: <br />].Enclose the component with a barrier completely preventing access, as noted. <br />2.Replace component with lead free components, completely or partially, as <br />noted in Specific Instructions, below. <br />NONE <br />1,19)211 <br />Component Location -Type Bedroom2 -- Door Casing <br />Window Type None <br />Description Substrate -Wood; Side -C -Side; Deterioration -Chipped or Peeled <br />Hazard YES Result XRF Test: 2.6 mg/cm2 <br />Assessment Notes <br />R/skAssessmentft.: 84000015462 Address: 628PARKAVE Page 9 of 23 <br />