Laserfiche WebLink
Single Phase Energy Hub Inverter with Prism Technology For North America <br />SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US(1) <br />SE3000H-US SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US UNITS <br />OUTPUT - AC ON GRID <br />Rated AC Power 3000 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V W <br />Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V W <br />AC Frequency Range (min - nom - max) 59.3 - 60 - 60.5(2)Hz <br />Maximum Continuous Output Current @ 240V 12.5 16 25 32 42 47.5 A <br />Maximum Continuous Output Current @ 208V - 16 24 - - 48.5 A <br />GFDI Threshold 1 A <br />Total Harmonic Distortion (THD) <3 % <br />Power Factor 1, adjustable -0.85 to 0.85 <br />Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes <br />Charge Battery from AC (if allowed) Yes <br />Typical Nighttime Power Consumption <2.5 W <br />OUTPUT - AC BACKUP(3) <br />Rated AC Power in Backup Operation(4) 3000 3800 6000 7600 10000 10300 W 7600* 10300* <br />AC L-L Output Voltage Range in Backup 211 - 264 Vac <br />AC L-N Output Voltage Range in Backup 105 - 132 Vac <br />AC Frequency Range in Backup (min - nom - max) 55 - 60 - 65 Hz <br />Maximum Continuous Output Current in Backup Operation 12.5 16 25 32 42 43 A 32* 43* <br />GFDI 1 A <br />THD <5 % <br />OUTPUT - SMART EV CHARGER AC <br />Rated AC Power 9600 W <br />AC Output Voltage Range 211 - 264 Vac <br />On-Grid AC Frequency Range (min - nom - max) 59.3 - 60 - 60.5 Hz <br />Maximum Continuous Output Current @240V (grid, PV and battery) 40 Aac <br />INPUT - DC (PV AND BATTERY) <br />Transformer-less, Ungrounded Yes <br />Max Input Voltage 480 Vdc <br />Nom DC Input Voltage 380 Vdc <br />Reverse-Polarity Protection Yes <br />Ground-Fault Isolation Detection 600kΩ Sensitivity <br />INPUT - DC (PV) <br />Maximum DC Power @ 240V 6000 7600 12000 15200 22000 22800 W 15200* 22800* <br />Maximum DC Power @ 208V - 6600 10000 - - 20000 W <br />Maximum Input Current(5) @ 240V 8.5 10.5 16.5 20 27 31 Adc 20* 31* <br />Maximum Input Current(5) @ 208V - 9 13.5 - - 27 Adc <br />Max. Input Short Circuit Current 45 Adc <br />Maximum Inverter Efficiency 99 99.2 % <br />CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % <br />2-pole Disconnection Yes <br />*Supported with PN SExxxxH-USMMxxxxxx or SExxxxH-USMNxxxxxx (1) These specifications apply to inverters with part numbers SExxxxH-USSMxxxxx or SExxxxH-USSNxxxxxx and connection unit model number DCD-1PH-US-PxH-F-x (2) For other regional settings please contact SolarEdge support (3) Not designed for standalone applications and requires AC for commissioning. Backup functionality is only supported for 240V grid(4) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated (5) A higher current source may be used; the inverter will limit its input current to the values stated