Laserfiche WebLink
INDIANA BUILDING CODES <br />2014 INDIANA BUILDING CODE (BASED ON 2012 INTERNATIONAL BUILDING CODE WITH 2014 INDIANA AMENDMENTS) <br />2012 INDIANA PLUMBING CODE <br />2009 INDIANA ELECTRICAL CODE (BASED ON 2008 NATIONAL ELECTRIC CODE WITH INDIANA AMENDMENTS) <br />2014 INDIANA MECHANICAL CODE (BASED ON 2012 INTERNATIONAL MECHANICAL CODE WITH 2014 INDIANA AMENDMENTS) <br />2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1 2007 EDITION) <br />2014 INDIANA FIRE PREVENTION CODE (BASED ON 2012 INTERNATIONAL FIRE CODE WITH 2014 INDIANA AMENDMENTS) <br />GENERAL BUILDING INORMATION <br />EXISTING BUILDING AREA 136,000 S.F. <br />TANK FARM 2,851 S.F. <br />UTILITY BLDG 2,052 S.F. <br />WAREHOUSE 48,853 S.F. <br />MAKING 49,734 S.F. <br />UTIL. / MECH. 2,133 S.F. <br />MAINTENANCE 2,615 S.F. <br />OFFICES 5,838 S.F. <br />TOILET / LOCKER 1,533 S.F. <br />CIRCULATION 20,391 S.F. <br />INTERIOR REMODEL <br />GMP SPACE -FILLING LINE 1,753 S.F. <br />NEW ADDITION 13,235 S.F. <br />TANK FARM 2,065 S.F. <br />TANK FILLING 3,178 S.F. <br />MAKING 6,545 S.F. <br />MAINT. RM. 591 S.F. <br />LAB 245 S.F. <br />ELECTRIC RM. 459 S.F. <br />TANK FARM VEST. 152 S.F. <br />USE GROUP <br />FACTORY F-1 (MODERATE HAZARD FACTORY) WITH ACCESSORY BUSINESS OCCUPANCY <br />GENERAL HEIGHTS AND AREAS <br />UNLIMITED AREA BUILDING <br />BUILDING EQUIPPED WITH AUTOMATIC SPRINKLER SYSTEM <br />SURROUNDED BY PUBLIC WAYS OF NOT LESS THAN 60 FEET <br />HEIGHT -2 STORIES <br />TYPE OF CONSTRUCTION <br />IIB <br />FIRE AND SMOKE PREVENTION FEATURES <br />FIRE RESISTANCE RATINGS OF BUILDING ELEMENTS <br />PRIMARY STRUCTURAL FRAME 0 HRS <br />EXTERIOR BEARING WALLS 0 HRS <br />INTERIOR BEARING WALLS 0 HRS <br />NON-BEARING WALLS 0 HRS <br />FLOOR CONSTRUCTION 0 HRS <br />ROOF CONSTRUCTION 0 HRS <br />BETWEEN B AND F-1 0 HRS <br />OPENING PROTECTIVES <br />1 HOUR RATED FIRE BARRIER 3/4 HOUR FIRE DOOR AND SHUTTER ASSEMBLY RATING <br />1 HOUR RATED EXIT ENCLOSURE 1 HOUR FIRE DOOR AND SHUTTER ASSEMBLY RATING <br />THERMAL AND SOUND INSULATING MATERIALS <br />CONCEALED INSULATION -FLAME SPREAD OF NOT MORE THAN 25 AND SMOKE DEVELOPED INDEX OF LESS THAN 450 <br />INTERIOR FINISHES <br />WALL AND CEILING FINISHES STAIRWAYS CORRIDORS ROOMS <br />B B C C <br />F-1 C C C <br />CLASS A -FLAME SPREAD INDEX 0-25; SMOKE DEVELOPED INDEX 0 -450 <br />CLASS B -FLAME SPREAD INDEX 26-75; SMOKE DEVELOPED INDEX 0 -450 <br />CLASS C -FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED INDEX 0 -450 <br />INTERIOR FLOOR FINISH <br />CLASS I OR II MATERIALS SHALL BE CLASSIFIED IN ACCORDANCE WITH NFPA 253 <br />FIRE PROTECTION SYSTEM <br />AUTOMATIC SPRINKLER SYSTEM -REQUIRED (UNLIMITED AREA BUILDING) <br />MEANS OF EGRESS <br />OCCUPANT LOAD <br />F-1 1 PERSON PER 200 S.F. <br />1 PERSON PER 500 S.F. FOR WAREHOUSE / STORAGE AREAS <br />EXISTING BUILDING AREA 424 PEOPLE <br />TANK FARM 6 PEOPLE (2,851 S.F./ 500) <br />UTILITY BLDG 4 PEOPLE (2,052 S.F./500) <br />WAREHOUSE 98 PEOPLE (48,853 S.F./500) <br />MAKING 249 PEOPLE (49,734 S.F./ 200) <br />UTIL. / MECH. 4 PEOPLE (2,133 S.F./500) <br />MAINTENANCE 5 PEOPLE (2,615 S.F./500) <br />OFFICES 58 PEOPLE (5,838 S.F./100) <br />TOILET / LOCKER -PEOPLE (1,533 S.F. SIMULTANEOUS USE) <br />CIRCULATION - PEOPLE (20,391 S.F. SIMULTANEOUS USE) <br />NEW ADDITION 52 PEOPLE <br />TANK FARM 4 PEOPLE (2,065 S.F./500) <br />TANK FILLING 6 PEOPLE (3,178 S.F./500) <br />MAKING 33 PEOPLE (6,545 S.F./200) <br />MAINT. RM. 3 PEOPLE (591 S.F./ 200) <br />LAB 3 PEOPLE (245 S.F./ 100) <br />ELECTRIC RM. 2 PEOPLE (459 S.F./ 200) <br />TANK FARM VEST.1 PERSON(152 S.F./ 200) <br />USE EXISTING NEW ADDITION TOTAL <br />B 58 PEOPLE - 58 PEOPLE <br />F-1 366 PEOPLE 52 PEOPLE 418 PEOPLE <br />424 PEOPLE 52 PEOPLE 476 PEOPLE <br />MEANS OF EGRESS SIZING <br />STAIRWAYS -0.3 INCH PER OCCUPANT LOAD SERVED <br />CORRIDORS -0.2 INCH PER OCCUPANT LOAD SERVED <br />ENCROACHMENT <br />DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN 7 INCHES <br />DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN ONE-HALF <br />COMMON PATH OF EGRESS TRAVEL <br />B 100 FEET <br />F-1 100 FEET <br />EXIT ACCESS TRAVEL DISTANCE <br />B 300 FEET <br />F-1 250 FEET <br />400 FEET (ONE STORY IN HEIGHT / MINIMUM HEIGHT FROM FL TO DECK 24 FEET / SPRINKLERED) <br />DOORS <br />SWING IN THE DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM WITH AN OCCUPANT LOAD OF 50 OR MORE <br />SPACE BETWEEN DOORS IN A SERIES SHALL BE 48 INCHES PLUS THE WIDTH OF THE DOOR <br />STAIRWAYS <br />7 INCH MAXIMUM RISER HEIGHT <br />11 INCH MINIMUM TREAD DEPTH <br />12'-0" MAXIMUM RISE BETWEEN FLOOR OR LANDING <br />HANDRAILS <br />EXTEND HORIZONTALLY 12" BEYOND TOP RISER <br />CONTINUE TO SLOPE FOR THE DEPTH OF 1 TREAD BEYOND BOTTOM RISER <br />HEIGHT NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES ABOVE STAIR NOSING <br />OUTSIDE DIAMETER OF NOT LESS THAN 1 1/4 INCHES AND NOT GREATER THAN 2 INCHES <br />GUARDRAILS <br />LOCATED ALONG OPEN SIDED WALKING SURFACES THAT ARE NOT MORE THAN 30 INCES TO THE FLOOR OR GRADE <br />HEIGHT NOT LESS THAN 42 INCHES <br />OPENING LIMITATION IN F AND S USE GROUPS -NOT ALLOW PASSAGE OF A 21 INCH SPHERE BETWEEN GUARDS <br />ENERGY CODE REQUIREMENTS <br />CLIMATE ZONE 5 <br />ROOF -R-30 U-0.032 <br />MASS WALLS -R-11; 4 ci U-0.090 <br />METAL BUILDING -R-13; 13 ci U-0.052 <br />METAL FRAMED - R-13; 7ci U-0.064 <br />PLUMBING FIXTURES <br />PLUMBING FIXTURES REQUIRED <br />OCCUPANCY WATERCLOSETS LAVATORIES DRINK. FOUNT SERVICE SINK <br />MALE FEMALE <br />B 1/25 FOR FIRST 50 1/25 FOR FIRST 50 1/40 FOR FIRST 80 1/100 1 <br />1/50 FOR REMAINDER 1/50 FOR REMAINDER 1/80 FOR REMAINDER <br />F-1 1/ /100 1 / 100 1/100 1/400 <br /> WATERCLOSETS LAVATORIES DRINKING FOUNT. SERVICE SINK <br />OCCUPANCY EXIST. NEW . EXIST. NEW ADD. EXIST. NEW ADD. EXIST. NEW ADD. <br />B 3 0 3 0 1 0 1 0 <br />F-1 4 1 4 1 1 --- <br />PLUMBING FIXTURES PROVIDED <br />WATERCLOSETS LAVATORIES DRINKING FOUNT. SERVICE SINK <br />EXISTING 9 (2 URINALS)5 (3 WASH FOUNTAINS)1 1 <br />NEW 1 1 (1 WASH FOUNTAIN)-0 <br />TOTAL 10 (2 URINALS)6 (4 WASH FOUNTAINS)1 1 <br />EXIT SIGN <br />22'-0" <br />T.D. = 62'-6" <br />C.P. = 22'-0"37'-0"T.D. = 30'-2" <br />C.P. = 0'-0" <br />EXIT SIGN <br />40'-6" <br />EXIT SIGN <br />15'-6" <br />EXIT SIGN <br />18'-0" <br />T.D. = 83'-10" <br />C.P. = 0'-0" <br />EXISTING <br />EXIT <br />EXIT SIGN <br />1'-6" <br />4'-4" <br />4'-6" <br />2'-4" <br />8"34'-0"EXIT DOOR <br />EXIT DOOR <br />EXIT DOOR <br />EXIT SIGN <br />EXIT SIGN <br />40'-0"58'-6"7'-0" <br />EXIT DOOR <br />EXIT SIGN <br />30'-0" <br />42'-0" <br />T.D. = 112'-0" <br />C.P. = 70'-0" <br />17'-0" <br />17'-0" <br />EXIT SIGN 98' <br />-0" <br />11'-0" <br />10'-10" <br />4'-0" <br />10'-6" <br />3'-0" <br />6'-6" <br />2'-0" <br />5'-6"8'-6"- <br />EXIT SIGNEXIT DOOR40'-0" <br />46'-0" <br />83'-4" <br />EXIT SIGN <br />NEW <br />DOOR <br />NEW <br />DOOR <br />EXIT SIGN <br />10'-0" <br />9'-0" <br />12'-0" <br />8'-0" <br />T.D. = 156'-6" <br />C.P. = 21'-0" <br />40'-0" <br />58'-6" <br />- <br />EXIT SIGN <br />EXIT SIGN <br />- <br />PROJECT NUMBER: <br />jedson.com <br />One Centennial Plaza <br />705 Central Ave <br />Cincinnati, OH 45202 <br />P: 513.965.5999 <br />F: 513.965.5998 <br />THIS DRAWING AND ITS RELATED COPYRIGHTS, INTELLECTUAL PROPERTY RIGHTS AND TRADE SECRETS ARE THE PROPERTY OF JEDSON <br />ENGINEERING, INC. AND CONTAINS CONFIDENTIAL INFORMATION, WHICH SHALL NOT BE USED, COPIED OR DISCLOSED WITHOUT WRITTEN PERMISSION <br />OF JEDSON ENGINEERING, INC. ©2013 JEDSON ENGINEERING, INC. ALL RIGHTS RESERVED. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />ABCDEFGHKLM <br />REVISIONS <br />ABCDEFGHJKLM <br />PROJ. NO.: <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />SCALE:11/4/2021 1:11:53 PMApprover <br />Checker <br />DLR <br />200199 <br />McCORMICK & COMPANY <br />LIFE SAFETY PLAN <br />ARCHITECTURAL <br />SOUTH BEND PLANT <br />8/2/2021SB-G102SB-G102 -D <br />200199 <br />3425 LATROP ST. SOUTH BEND, INDIANA 46628 <br />3/32" = 1'-0"2 LIFE SAFETY PLAN <br />3425 LATHROP ST. SOUTH BEND, INDIANA 46628 <br />NO DESCRIPTION DATE DB CB AB <br />A LAYOUT E 8/3/2021 DLR DLR <br />B LAYOUT PROGRESS 8/11/2021 DLR DLR <br />C LAYOUT G 8/25/2021 DLR DLR <br />D ISSUED FOR REVIEW 11/01/2021 DLR DLR