Laserfiche WebLink
DN <br />DN <br />MCC <br />BOILER RM. <br />MC DONALD'S PREMIX 2 <br />MC DONALD'S TUBE LINE (PREMIX 1) <br />STUBBS MAKING <br />AND PACKING <br />LAWRY'S MAKING <br />AND PACKING <br />MC DONALD'S KETCHUP <br />AND GRAPE JELLY MAKING <br />GMP SPACE <br />1,739 S.F. <br />NEW GLASS LINE <br />NEW GLASS LINE <br />PALLETIZER <br />EXISTING COLD STORAGE <br />NEW INSULATED <br />METAL WALL <br />PANEL <br />2 <br />GLYCOL <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />COMPACTOR <br />RECYCLING <br />RECYCLING <br />SB-A101 <br />1 <br />SB-A102 <br />1 <br />SB-A103 <br />1 <br />SB-A103 <br />2 <br />SHIPPING <br />RECEIVING <br />SB-A101 <br />2 <br />STUBBS <br />MAINTENANCE <br />JELLY <br />KETCHUP <br />TANKER UNLOAD <br />ADDITION <br />MAKING <br />ADDITION <br />MAINT. <br />ADD. <br />TANK <br />FARM <br />ADDITION <br />TANK FARM <br />CIP <br />ELECT. <br />WASTE WATER <br />COMPRESSORS <br />OFFICES <br />BREAK RM. <br />COMPRESSOR <br />PACKAGING <br />CRYOVAC <br />SB-A102 <br />4 <br />WATER <br />TREAT <br />BRINE <br />TANK <br />35'-0"81'-6"83'-4"80'-6 3/8"37'-6" <br />acid/caustic <br />27'-10"52'-6"SLOPE 1/4" / FT. <br />SLOPE <br />EXISTING MEMBRANE <br />ROOF <br />NEW MEMBRANE ROOF <br />EXISTING MEMBRANE <br />ROOF <br />SLOPE <br />EXISTING BUILT-UP <br />ROOFING <br />SLOPE <br />EXISTING GUTTER <br />- <br />BUILT-UP INSULATION <br />TO ACHIEVE POSITIVE <br />DRAINAGE <br />NEW MEMBRANE ROOF <br />PREFINISHED <br />METAL GUTTER <br />PREFINISHED <br />METAL GUTTER <br />EXISTING METAL <br />ROOF PANELS <br />TO REMAIN <br />NEW MEMBRANE ROOF <br />PREFINISHED <br />METAL GUTTER <br />ROOF HATCH -CENTER <br />ABOVE TANK MANWAY <br />OPENING <br />ROOF SADDLE -TYP. <br />AT ROOF HATCH <br />MEMBRANE <br />FLASHING PER <br />ROOF MANUFACTURER'S <br />RECOMMENDATIONS <br />SLOPE 1/4" / FT.- <br />SLOPE <br />SLOPE 1/4" / FT.ROOF DRAIN <br />ROOF HATCH <br />PREFINISHED <br />METAL GUTTER <br />PREFINISHED <br />METAL COPING <br />PREFINISHED <br />METAL COPING <br />ROOF DRAIN <br />GALVANIZED <br />STEEL GUARDRAIL <br />AT 42" A.F.F. -TYPICAL <br />AROUND PLATFORM <br />PROJECT NUMBER: <br />jedson.com <br />One Centennial Plaza <br />705 Central Ave <br />Cincinnati, OH 45202 <br />P: 513.965.5999 <br />F: 513.965.5998 <br />THIS DRAWING AND ITS RELATED COPYRIGHTS, INTELLECTUAL PROPERTY RIGHTS AND TRADE SECRETS ARE THE PROPERTY OF JEDSON <br />ENGINEERING, INC. AND CONTAINS CONFIDENTIAL INFORMATION, WHICH SHALL NOT BE USED, COPIED OR DISCLOSED WITHOUT WRITTEN PERMISSION <br />OF JEDSON ENGINEERING, INC. ©2013 JEDSON ENGINEERING, INC. ALL RIGHTS RESERVED. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />ABCDEFGHKLM <br />REVISIONS <br />ABCDEFGHJKLM <br />PROJ. NO.: <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />SCALE:11/4/2021 1:08:47 PMPB <br />PB <br />DLR <br />200199 <br />1"=30'-0" <br />McCORMICK & COMPANY <br />COMPOSITE FLOOR PLAN <br />ARCHITECTURAL <br />SOUTH BEND PLANT <br />6/20/2021SB-A100SB-A100 -I <br />200199 <br />1" = 30'-0"1 COMPOSITE FLOOR PLAN <br />1" = 20'-0"2 ROOF PLAN <br />3425 LATHROP ST. SOUTH BEND, INDIANA 46628 <br />NO DESCRIPTION DATE DB CB AB <br />B LAYOUT B 6/25/2021 DLR DLR <br />C LAYOUT C 7/6/2021 DLR DLR <br />D LAYOUT D 7/13/2021 DLR DLR <br />E LAYOUT E 8/3/2021 DLR DLR <br />F LAYOUT PROGRESS 8/11/2021 DLR DLR <br />G LAYOUT G 8/25/2021 DLR DLR <br />H GENERAL REVISIONS 10/1/2021 DLR DLR <br />I ISSUED FOR REVIEW 11/01/2021 DLR DLR