Laserfiche WebLink
SHEETSHTLLLIVE LOADDETAILDETSTRUCTURAL GRID REFERENCETEST BORING & NO.EXISTING CONTOURNEW CONTOURNEW POINT ELEVATIONDOOR NUMBERWINDOW TYPEEXISTING POINT ELEVATIONARCHITECTURAL DRAWING SYMBOLS LEGENDDRINKING WATER COOLERDRINKING FOUNTAINKEY NOTE1E815.2'12A815.2'815.2'815.2'LEVEL LINETB # 1DWGDWCDIMDIVDIA / DLDSDFDEAD LOADDRAWINGDOWNSPOUTDIMENSIONDIVISIONDIAMETERINTERIOR ELEVATION REFERENCE4A3.1231ROOM NO. SEE SCHEDULE FOR ROOMSQ YD / SYSQ IN / SISPSIMSQSPKRSQ FT / SFSPEC(S)SCALE: 1/8" = 1'-0"FRONT ELEVATIONA2.1187A1.5DETAIL OR SECTION TITLEBUILDING SECTIONROOF SLOPE12 1A3.1AREA & CEILING HEIGHTDETAIL REFERENCEWALL OR DETAIL SECTION109USHER3A4.2LONG LEG HORIZONTALMASONRYLONG WAYMATERIALLOUVERMETER / THOUSANDLONG LEG VERTICALMMATMASLLHLLVLWLVRCASEWORK NUMBEREQUIPMENT NUMBERE18C12TO BE REMOVEDNEW DOOR AND FRAMEEXISTING PARTITION TO BE REMOVEDNEW PARTITIONEXISTING DOOR AND FRAMESQUARE YARDSQUARE INCHESSQUARE FEETSPECIFICATION(S)SQUARESPACESIMILARSPEAKERBASE BUILDING PARTITION TO REMAINEXISTING PARTITION TO REMAINDATED NOVEMBER 1986 FOR ANY ABBREVIATION USED ON THE DRAWINGS BUT ARE NOT LISTED BELOW.ABBREVIATIONS USED ON DRAWINGS IN GENERAL ARE LISTED BELOW. REFER TO CSI DOCUMENT TD 2-4PENNY (NAILS, ETC.)CEMENTITIOUS WOOD FIBERCENTER TO CENTERCOUNTER SINKCONTINUOUS / CONTINUECONSTRUCTIONCONCRETE MASONRY UNITCERAMIC MOSAIC TILECORRUGATED METAL PIPECONTROL JOINTCABINET HEATERCUBIC FEET PER MINUTECHALKBOARD / CATCH BASINAIR CONDITIONINGACOUSTICAL CEILING TILEABOVE FINISHED FLOORACCORDION FOLDING PARTITIONACCESS PANELARCHITECT(URAL)ACOUSTICAL WALL TREATMENTAMERICAN WIRE GAUGEACID RESISTANTBENCH MARK / BEAMBOTTOM OF STEELBUILT UP ROOFARCHITECTURAL AND STRUCTURAL ABBREVIATIONSCONCRETECONCCUBIC YARDCU YD/CYDEPTCWCUSPCWFDCoDdDISPLAY CASEDEPARTMENTDEGREEDEPTH / DEEPCOLD WATERCUSPIDORCONTRCORRC TO CCU FT/CFCSKCU IN/CICONTCONSTRCTCERAMIC TILECUBIC FEETCUBIC INCHCONTRACTORCORRUGATEDCJCOMPCOLCMUCMTCMPCLGCLRCOCLCOMPACTEDCOLUMNCLEANOUTCEILINGCLEARCENTERLINECFMCATCARCABBURBRKCICHCBCATALOGCAST IRONCARPETBRICKCABINETBRGBOTBOSBLKGBLDGBMLBIT&BLOCKINGBOTTOMBEARINGANGLEANDBUILDINGBITUMINOUSAWTAWGASPHARCHAPPROXALTAVARAPALAUDIO-VISUALASPHALTALUMINUMAPPROXIMATEALTERNATIVEAGGAFPAFFADJACTADACAREA DRAINAGGREGATEADJUSTABLEPERFPAPLASPLAS LAMPLPLYWDPSPREFABPSFPSSPSIPLBGPVMTRQTRAD / RRCPRBRARDREFRREFREQ'DRMREVREINFROSROWSASANSDSEWSECTSGFTSCHEDPVCINSIDE DIAMETERINCHINCLUDE(D), (ING)INFORMATIONINVERTKITCHENJOINTJOISTJOIST SUBSTITUTEINTERIORPOUNDLOCKERLAMINATE(D)LAVATORYINSULATION / INSULATELENGTHJSTLLKRLAVLB / #LAMKITJTINSULINVJSINTRIDINCLINFOIN/"GAUGEFIRE EXTINGUISHERGRAB BARGALVINIZE(D)FIRE EXTINGUISHER CABINETGLASSGYPSUM WALLBOARDHEIGHT / HIGHHOSE BIBBHARDWAREHOLLOW METALHIGH POINTHIGHWAYHIGH STRENGTHHEATINGHEATING/VENTILATING/AIR CONDITIONINGHOT WATERHORIZONTALHBHSHWHTGHVACHWYHDWEHORIZHMHPTGBGLHGWBFEFECGAGALVW / O WITHOUTRESILIENT BASERIGHT-OF-WAYSUPPLY AIRSTORM DRAIN / SMOKE DETECTORSTRUCTURAL GLAZED FACING TILESCHEDULESECTIONSEWERSOUTHSANITARYREINFORCED CONCRETE PIPEREFERENCEREVISION(S)REINFORCINGROOF DRAINREFRIGERATORROUGH OPENINGROOMREQUIREDYDYARD / YARD DRAINYRYEARWHWSSKWWFWPWAWBWCWDWATER HEATERWORKING POINTWALL SERVICE SINKWELDED WIRE FABRICWARDROBE ACCESSORIESWATER CLOSET / WIND COLUMNWOOD BASEWOODPOUNDS PER SQUARE INCHPENCIL SHARPENER SUPPORTQUARRY TILERETURN AIRPOLYVINYL CHLORIDERISERRADIUSPAVEMENTPUBLIC ADDRESSPERFORATEDPLASTIC LAMINATEPLATE / PROPERTY LINEPREFABRICATEDPROJECTION SCREENPOUNDS PER SQUARE FOOTPLUMBINGPLYWOODPLASTERVITVITREOUSVSVTW /WVNRVOLVRBVRVENT STACKWEST / WIDE / WIDTHVINYL TILEWITHVAPOR RETARDERVENTED RESILIENT BASEVENEERVOLUMEURVCTVERTVIFUONULUCUVURINALVINYL COMPOSITION TILEVERIFY IN FIELDVERTICALUNDERWRITERS LABORATORYUNLESS OTHERWISE NOTEDUNIT VENTILATORUNDERCUTMAXMECHMBMFRMINMHMEZZMMMETMONICNOMNO / #NODOCOPPO TO OOPP HDOPNGNTSOZOWMISCEXPANSIONFINISHFIRE HOSE CABINETFLOORFOOTINGFEETFINISH FLOORFLOOR SERVICE SINKFOUNDATIONFLEXIBLE SHEET ROOFINGEXHAUSTEXTENSIONFLOOR DRAINEXTERIOREXISTINGEQUALEACH WAYEXTERIOR INSULATION AND FINISH SYSTEMEQUIPMENTFDNFSSKFT/ 'FTGFSRFIN FLFINFHCFDFLREXTEXISTEXPEXTNEQUIPEWEXHEIFSEQEXPANSION JOINTENGINEERELECTRICAL PANELBOARDELEVATIONEACHEACH FACEEASTEFELENGREJEPEEAON CENTEROPPOSITE HANDOUT TO OUTOUTSIDE DIAMETEROPERABLE WALLOUNCEOPPOSITEOPENINGMILLIMETERMASONRY OPENINGNOT IN CONTRACTNOT TO SCALEMISCELLANEOUSNOMINALNUMBERNORTHMETALTOMTOSTYPTWSTVTHRTEMPTERTOCTOFTOP OF MASONRYTACKABLE WALL SPACETOP OF STEELTYPICALTELEVISIONTOP OF FOOTINGTOP OF CONCRETETHRESHOLDTEMPORARYTERRAZZOT & GTELTATBTCSYNTHT & BSYMMTTONGUE AND GROOVETOILET ACCESSORY(IES)TACKBOARDTOP OF CURBTELEPHONETOP AND BOTTOMSYMMETRY(ICAL)SYNTHETICTREADMECHANICALMARKER BOARDMANUFACTURERMEZZANINEMANHOLEMINIMUMMAXIMUMSUSPSTDSTLSTRUCTSWSSTSTSHORT WAY / SIDEWALKSTANDARDSTEELSTRUCTURALSUSPENDEDSTAINLESS STEELSTORM / STREET1126 Lincolnway EastDRAWING REPRODUCTION:COPIES OF ORIGINAL DOCUMENTS WILL BE RELEASED FOR BIDDING AND CONSTRUCTIONPURPOSES AS COMPLETE SETS IN FULL; INCLUDING BOTH DRAWINGS AND SPECIFICATIONS. NOPARTIAL SETS ARE TO BE DISTRIBUTED. NEITHER THE OWNER, ARCHITECT AND/OR ENGINEER,ASSUMES RESPONSIBILITY FOR ERRORS OR MISREPRESENTATIONS RESULTING FROM THE USEOF INCOMPLETE SETS OF BIDDING DOCUMENTS.RIGID INSULATIONBATT INSULATIONPLYWOODFAX (574) 289-2420South Bend, Indiana 46601www.kilarchitecture.comPHONE (574) 288-2654ARCHITECTURAL MATERIAL SYMBOL LEGENDLAMINATED WOOD BEAMSLATETERRAZZOSAND, GROUT, PLASTER, GWBGRAVEL OR STONECONCRETEEARTHASPHALTWWF IN CONCRETE SLABMETAL ROOF DECKREINFORCING BARSMETAL (IN SECTION)WOOD OTHER THAN NOMINALMETAL SHAPESWIRE FENCE OR PARTITIONCORRUGATED METAL FORMINGACOUSTIC TILE CEILINGCARPETFINISH WOODROUGH WOODSTRUCTURAL GLAZED TILE OROR OPERABLE WALLSOLID PANEL FOLDING PARTITIONTERRA COTTA (LARGE SCALE)STUD WALLCERAMIC TILE, QUARRY TILE, GLAZED BRICKFIRE BRICKFACE BRICKPRECAST CONCRETENOTE:STRUCTURAL DESIGN OF THIS RESIDENCE IS NOT THE RESPONSIBILITY OF THE ARCHITECT AND ISTHE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THIS INCLUDES BASEMENT/FOUNDATIONWALLS/FOOTERS, FLOOR, WALL AND ROOF FRAMING, BEAMS, LINTELS AND WIND/LATERALLOADING.GENERAL NOTES:THESE DRAWINGS ARE GENERAL DESCRIPTIONS OF THE MATERIALS AND PRODUCTS TO BE USEDTO COMPLETE THIS NEW BUILDING. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE,COMPARE EXISTING CONDITIONS WITH PROPOSED PLANS AND SPECS AND PROVIDE SITEPREPARATION AND ANY OTHER MINOR COMPONENT REQUIRED TO COMPLETE THE NEW BUILDING.CONTACT ARCHITECT IMMEDIATELY WHERE INCONSISTENCIES ARE DISCOVERED.SHEET DRAWING INDEXKIL ARCHITECTURE / PLANNINGADDITION FOR THE:1316 EAST WAYNE STREET SOUTHSOUTH BEND, INDIANA 46637HOCHSTETLERNSITE LOCATION MAPLOCATIONPROJECTGENERALC0.0COVER SHEETC0.1DRAWING INDEXCIVILC1.1SITE PLANDEMOLITIOND1.1-ARCHITECTURALA1.1FLOOR AND ROOF PLANSA2.1ELEVATIONSRESIDENCENOTE:SITE DESIGN FOR THIS RESIDENCE IS BASED UPON SITE INFORMATION FOUND ON MACOG/GIS.CONTRACTOR TO VERIFY EXISTING PROPERTY BOUNDARIES, TOPOGRAPHIC INFORMATION, ANDUTILITY LOCATIONS IN THE FIELD PRIOR TO CONSTRUCTIONEXISTING BUILDING - GARAGE860 sfGROSSTOTAL BLDG AREA:1,576 sfAREAS:ADDITION - ADU716 sfSQUARE FOOTAGEINDEXG1.0IKLP L A N N I N GA R C H I T E C T U R E10664GREGORY A. KILA R C H I T E C TN C A R B A I A5 7 4 . 2 8 8 . 2 6 5 4S O U T H B E N D, I Nwww.kilarchitecture.com1126 LINCOLNWAY EASTCCOPYRIGHT 2022KIL ARCHITECTURE / PLANNINGKAP.21092HOCHSTELTERRESIDENCEADDITION1316 E WAYNE ST.SOUTH BEND, IN46617PRELIMINARY <br />NO <br />T <br /> <br />FO <br />RCONSTRUCTIONTHIS DOCUMENT AND THE DESIGN IS THE PROPERTY OF KILARCHITECTURE / PLANNING AND THE USE IS LIMITED TO THESPECIFIED PROJECT. THE ARCHITECT SHALL BE DEEMED THEAUTHOR OF THIS DOCUMENT AND SHALL RETAIN ALL COMMON LAW,STATUATORY, AND OTHER RESERVED RIGHTS, INCLUDING THECOPYRIGHT. THIS DOCUMENT MAY NOT BE REPRODUCED, COPIED,OR USED WITHOUT THE WRITTEN PERMISSION OFKIL ARCHITECTURE / PLANNING.REVISIONSCHEMATIC DESIGN-HPCJANUARY 03, 2021