My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Industrial Wastewater Discharge Permit Renewal - Honeywell International, Inc.
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2021
>
Licenses & Permits
>
Industrial Wastewater Discharge Permit Renewal - Honeywell International, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2021 3:20:00 PM
Creation date
9/14/2021 3:19:47 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Recommendations
Document Date
9/14/2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Honeywell Groundwater Remediation Industrial Wastewater Discharge Permit page 1 of 39 <br />Facility Description <br />Honeywell International, Inc. Naphtha Recovery Well system and VOC Recovery Well system currently act as <br />water-table depression wells to control groundwater from migrating off-site. Catalytic-oxidation Soil Vapor <br />Extraction (SVE) treatment system was installed to remove volatile organic compounds from the soil above the water table. <br />There are four operating VOC Recovery Wells (EW-1-R, EW-2, EW-3, and EW-5-R), three operating Naphtha <br />Recovery Wells (E3A, RWB16, and RWB23), and one discharge point for spent scrubber water from the Soil <br />Vapor Extraction System (003C00175). <br /> PART I – EFFLUENT LIMITATION <br /> Sample Port and Collection Location <br />1.Sample monitoring is located at the Naphtha Recovery Well system and VOC Recovery Well <br />system. Samples are collected from spigots at each well. For the Soil Vapor Extrusion system <br />sample monitoring is done at the sampling port after the Flow Meter on the discharge pipe of the <br />frac tank. Wastewater from the frac tanks will be transferred with a dedicated tanker truck to <br />Discharge Location # 003C00175, near Plant 14. <br />2.Sample Sites EW-1-R, EW-2, EW-3, EW-5-R, E3A, RWB16, RWB23, and 003C00175 shall not <br />exceed the following effluent limitation: Any discharge of water or waste having a pH lower than <br />6.0 S.U. or a pH higher than 11.0 S.U. is prohibited. In addition, the permittee’s wastewater <br />discharge shall not exceed the following effluent limitations: <br /> Parameter Daily Maximum Limit (mg/L) <br />Arsenic (mg/L) Report <br />B-TEX (ug/L)Report <br />Cadmium (mg/L) Report <br />Chromium (mg/L) Report <br />Copper (mg/L) Report <br />Cyanide (mg/L) Report <br />Closed Cup Flashpoint (Degrees F) * <140 Degrees Fahrenheit Prohibited <br />Lead (mg/L) Report <br />Mercury (mg/L) Report <br />Nickel (mg/L) Report <br />Oil and Grease – Total (mg/l) 300 <br />Oil and Grease TPH (mg/L) 100 <br />Organic Priority Pollutants (ug/L) Report <br />Silver (mg/L) Report <br />Zinc (mg/L) Report
The URL can be used to link to this page
Your browser does not support the video tag.